Technical Manual
Installation and Operation
© SPECTRA ENGINEERING 2022 Revision 1.0.0
11
2.3.1.4
Configure Alarm LED
The MX940 has an LED to display the status of alarms. The alarm trigger conditions
can be set using the built-in radio configuration menu system software. The LED can
be set to trigger on low forward power, high reflected power, power supply voltage
out of range, VCOs unlocked and high PA temperature. The status of the alarm
conditions can be expanded in the on-line diagnostics mode.
Please refer to the radio configuration menu system for additional setup information.
2.3.2 Adjustments
The MX940 has adjustable parameters which are under the control of the Micro
Controller. These comprise of TX power, TX VCO deviation, TX reference oscillator
deviation and TX reference oscillator frequency. All of these are adjusted with the aid
of the built-in radio Alignment menu system. The MX940 comes pre-aligned from the
factory, so in most cases no alignment will not be necessary.