background image

Welcome

Welcome

A personal welcome to you from the management and employees of Speco Technologies

All of the co-workers here at Speco Technologies are dedicated to providing excellent products with inherently
good  value, and we are delighted you have purchased one of our products.

We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete
satisfaction, we will endeavor to make things right.

* This product may overheat if installed in closed box or ill-ventilated place.

RISK OF ELECTRIC SHOCK

DO NOT OPEN 

CAUTION

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING

To prevent fire or shock hazard, do not
expose the unit to rain or moisture.

*Do not install this equipment in a confined space such as a book case or similar unit.
*The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus.
WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.
near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do
not fall and liquids are not spilled into the enclosure through openings.
WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions.
WARNING: It has heed to be easy to disconnect the device. To disconnect the device from power, separate AC input cable from inlet or unplug the

AC Cord.

WARNING: This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
WARNING: The appliance inlet or ac mains attachment plug are considered as the main disconnect device.
Caution: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any

servicing other than that contained in the operating instructions unless you are qualified to do so.

NOTE : This equipment has been tested and found to comply with the limits for a Class A digital device,  pursuant to Part 15 of the FCC Rules. These

limits are designed to provide reasonable protection against  harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense. 

This symbol is intended to alert the user to the
presence of uninsulated “dangerous voltage” within
the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to
persons.

This symbol is intended to alert the user to the
presence of important operation and maintenance
(servicing) instructions in the literature accompanying
the appliance.

Caution: To prevent electric shock do not use this (polarized) plug with

an extension cord, receptacle or other outlet unless the blades
can be fully inserted to prevent blade exposure.

Attentions: Pour prévenir les chocs électriques ne pas utiliser cette

fiche polarisée avec un prolongateur, une prise de courant
on une autre sortie de courant, sauf si les lames peuvent
étre insérées à fond sans en laisser aucune partie à
découvert.

PUBLIC ADDRESS AMPLIFIER  

Содержание P120FACD

Страница 1: ...Public Address Amplifier P120FACD P240FACD OperationManual...

Страница 2: ...mains socket outlet with a protective earthing connection WARNING The appliance inlet or ac mains attachment plug are considered as the main disconnect device Caution These servicing instructions are...

Страница 3: ...ronment 2 Important Safety Instructions 2 Features 3 Operation 4 Additional Descriptions 4 Front Panel 5 Rear Panel 8 Connecting Speakers 11 FM Operation 12 CD Operation 13 Channel EQ SETUP 14 SETUP M...

Страница 4: ...d on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the ca...

Страница 5: ...you to select any combination of up to five speakers RS 232C IN OUT CONTROL AMX CRESTRON Interface can be used with the RS 232C terminal DIGITAL 3 BAND EQ Digital 3 band EQ for 6 Mic inputs PRIORITY M...

Страница 6: ...MP3s it then becomes about 4 5MB WMA WINDOWS MEDIA AUDIO WMA is a multimedia compression method developed by Microsoft Corporation and is used to compress music exclusively used in Windows Media Tech...

Страница 7: ...tate 1 minute after the protection circuitry has been activated If you want to release the protection manually press the POWER switch 2 SPEAKER SELECTOR These switches are used to select speaker outpu...

Страница 8: ...TUNING Button In CD function Backward Search and Forward Search Button In FM function Tuning Down and Tuning UP Button 9 EJECT BUTTON Press this button to eject the CD from the unit 10 CHIME BUTTON C...

Страница 9: ...el of the 3 Band MIC Tone To adjust the level of a tone press ENTER button to enter into the EQ Mode Press the tone button H M or L of the channel you want and adjust the tone control volume and then...

Страница 10: ...are for connecting speaker wire Only connect speakers for which the total sum of the impedance is equal to or higher than the rated output impedance Only the 70V terminals Speaker zones 1 5 controlled...

Страница 11: ...ed to a telephone exchange system When the telephone signal is input all the other input signals are muted 11 MUSIC ON HOLD TERMINALS These terminals output the internally selected source This is a ba...

Страница 12: ...t can be used to record the signal from the unit The output level is not controlled by the master volume Output Level 0dBV POST OUT This is the unbalanced output This output can be used to monitor the...

Страница 13: ...speaker to the high impedance terminals WARNING Extreme care must be exercised when connecting high impedance systems as potentially hazardous voltages may be present at these terminals Do not install...

Страница 14: ...hed When complete the VFD will display TUNED and you will be able to listen to the station MEMORY RECALL STATION 1 Choose the station you want via the TUNING buttons 2 Press the MEMO button and the VF...

Страница 15: ...check the disk for any of these circumstances EJECT 1 Press the EJECT button to remove the disk 2 The disk will eject regardless of the current state of the player REPEAT FUNCTION REPEAT 1 1 Repeats...

Страница 16: ...annels 5 Press the ENTER button to exit the EQ modes You will auto save and exit the EQ mode if no key is pressed for 10 seconds Please refer to the below example EX CH1 EQ SETUP HIGH 2dB MID 10dB LOW...

Страница 17: ...UP Mode Press the H of CH1 and CH6 at the same time to enter into the SETUP mode Turn the volume to enter into each setup function MIC 1 2 Mute level Tel In volume Chime volume etc Press the H button...

Страница 18: ...Press ENTER Choose ON or OFF Press ENTER ON Beep sound OFF Beep does not sound 5 IR REMOTE CONTROL You can set the optional IR Remote Control function on or off Select IR REMOCON from the menu and pre...

Страница 19: ...DISC INTRO HIGH DENSITY 1 BIT D A CONVERTER RANDOM DIGITAL AUDIO COMP ACT 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 PROG TRACK INDEX INTRO RANDOM REPEAT ALL 1 DISCS PRE AMPLIFIER PP 9113 0 10 MIXER...

Страница 20: ...PUBLIC ADDRESS AMPLIFIER 18 P120FACD P240FACD Block Diagrams Block Diagrams...

Страница 21: ...ensitivity 60dBV 10k S N A WTD 50dB Frequency Response 3dB 120Hz 10kHz TEL IN TEL IN 1kHz PRE OUT Input Sensitivity 10dBV 10k S N A WTD 65dB Frequency Response 3dB 330Hz 3kHz CD Test CD 0dB 1kHz PRE O...

Страница 22: ...ed outside of the factory This limited warranty does not apply to broken cases batteries or other physically damaged parts Unless requested the company will replace and return all merchandise in the p...

Страница 23: ...21 P120FACD P240FACD...

Страница 24: ...MADE IN KOREA July 2009 124216 200 New Highway Amityville NY 11701 Phone 631 957 8700 Toll Free 1 800 645 5516 www specotech com...