O2MB1/O2MB1W
Owner’s Manual
O2MB1
Full HD Mini-bullet IP Camera
Страница 1: ...O2MB1 Full HD Mini bullet IP Camera...
Страница 2: ...uraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equ...
Страница 3: ...s s G Gu ui id de e Rev 1 2 Apr 2014 3 Revision History Date Revision Details Mar 4 th 2014 1 0 First manual revision creation Mar 7 th 2014 1 1 Text revisions Apr 25 th 2014 1 2 Modified 2 3 3 Front...
Страница 4: ...itch 10 2 4 Functional Description 11 3 On Site Installation 13 4 Getting Started 14 4 1 PC Requirement 14 4 2 Quick Installation Guide 14 4 2 1 Connect PC and O2MB1 to network 14 4 2 2 Install Speco...
Страница 5: ...ication is available through the bidirectional audio communication feature Designed to be a stand alone streaming audio video transmission device O2MB1 can be applied to various applications such as v...
Страница 6: ...type resolution and frame rates for each profile Intelligent Bit Rate Control VBR or CBR PTZ Digital PTZ Video crop Image Setting Text overlay Privacy mask De interlace filter Motion detection 3 regi...
Страница 7: ...re Speco NVR Windows XP Vista 7 free of charge Speco ONSIP Android iPhone iPad free of charge Miscellaneous Operating Temperature 0 C 45 C 32 F 113 F Operation Humidity 8 80 RH Power DC 12V 0 5A Dimen...
Страница 8: ...deo Cable 1EA Screws Anchors L type wrench with six angles CD Software User s Guide Quick Reference Guide Quick installation guide 2 2 Product Preview O2MB1 O2MB1W ONSIP Installer VMS Software Speco N...
Страница 9: ...O O2 2M MB B1 1 U Us se er r s s G Gu ui id de e Rev 1 2 Apr 2014 9 2 3 Physical description 2 3 1 External View Figure 2 1 External view of O2MB1 2 3 2 Dimension Figure 2 2 Dimension Unit mm...
Страница 10: ...tch Factory default switch is provided for returning the IP camera to factory default state Unscrew the cover to access the switch There are two functions assigned to factory default switch 1 Returnin...
Страница 11: ...D It will be lit in green or red depending on the status Green Green color indicates that the camera is in normal operation mode Continuous green indicates that data transmission is possible Blinking...
Страница 12: ...pply this connection when either voltage or current exceed the limit Figure 2 6 RELAY Output connection Sensor Input Connect external alarm sensor Examples of sensing devices are infrared sensor motio...
Страница 13: ...e installation so that no moisture is allowed to penetrate into the unit through the cables or conduits during the life time of the product Products of which the internal parts are exposed to moisture...
Страница 14: ...it Web Browser Internet Explorer 8 9 Internet Explorer 8 9 Graphic Card Video RAM 256MB Resolution 1920x1080 Video RAM 1GB Higher than 1920x1080 Network 10 Base T Ethernet 100 Base T Ethernet Operatin...
Страница 15: ...needed to assign connection information to Speco NVR program before connection Insert the CD provided with product into the PC and install Speco NVR Figure 4 2 Speco NVR Follow the sequence below for...
Страница 16: ...etwork mode that best suits from the drop down list in 5 You can choose either Static or ADSL and Auto DHCP respectively If ADSL and Auto are selected the fields in 6 are deactivated In case of ADSL f...
Страница 17: ...should be installed on your PC before actual connection If your PC is not connected to the internet you cannot download Active X module Most convenient way of installing the Active X module is install...
Страница 18: ...d and port and then click the save button After assignment procedure you must click the SAVE button You can see the live video when you click the live view button as below When you exit Speco NVR you...
Страница 19: ...ted target application parameters need to be changed through the admin page The admin page can be connected through http IP_Address Port_Number admin htm ID and password of the administrator are requi...
Страница 20: ...t 2 The LAN switch supports standard PoE Make sure that both the IP camera and the LAN switch support standard PoE IEEE 802 3af In case of DC adaptor If PoE is not applied the power and network connec...
Страница 21: ...md Ping IP address Ex Ping 172 16 42 51 If Reply from message is returned in the figure below the network connection is in normal state Try connection to the video again If the problem persists or ref...
Страница 22: ...ording and still video capture in Speco NVR and Web Viewer Windows Vista 1 UAC User Access Control configuration 1 Double click User Accounts in control panel 2 Double click Turn User Account Control...
Страница 23: ...s se er r s s G Gu ui id de e Rev 1 2 Apr 2014 23 Windows 7 1 UAC User Access Control configuration 1 Double click User Accounts in control panel 2 Double click Change User Account Control setting 3 S...
Страница 24: ...B1 1 U Us se er r s s G Gu ui id de e Rev 1 2 Apr 2014 24 2 Privilege Level Control 1 Select NVR icon on the desktop 2 Click right mouse button and select properties 3 Check Privilege Level in Compati...
Страница 25: ...25 5 4 Technical Assistance If you need any technical assistance please contact your dealer For immediate service please provide the following information 1 Model name 2 MAC address and Registration n...
Страница 26: ...y default button for 1 sec to unmount the SD Card SD Card can also be unmounted by going to Admin Page Sensor Capture Setup and clicking on CONFIRM button at the right of SD Card Unmount menu 2 Unplug...