9.0 fleaPower™ Control Line
To reduce the average current required by the reader, pull the purple conductor low.
10.0 Connection
Connection must be done in accordance with NFPA 70. Do not connect to a receptacle controlled by a switch. Connect to a power limited DC
voltage source.
11.0 Troubleshooting
1. When the reader is first powered on it will beep 4-times, and the LED will shine red.
2. Presenting a supported access credential will result in the reader beeping and the LED flashing once.
NOTE: The access panel controls LED functionality, such as switching the LED to green.
If the reader does not recognize the card or tag (no beep, no LED flash) or exhibits short read range, please see the table below for possible
causes and solutions.
Possible Cause
Corrective Action
Incorrect cabling
Verify gauge, connections and cabling length
Not enough power
12 VDC recommended, 5 VDC at reader is minimum
Incorrect card used
Verify if card technology is supported
Reader/access panel not properly grounded
Earth ground needed—verify shield and reader ground are tied at access panel and connect
to ground at one point
Supply generating interference
Linear power supply recommended, verify switching power supply before use
Should any of the corrective actions mentioned above not improve performance, disconnect the reader from the access panel and power it with a
separate power supply or 9VDC battery, and re-test card functionality. By powering the readers separately, most variables that may lead to
reduced performance can be eliminated. Should the problem persist, please contact Speco Technologies directly.
Many Speco Technologies readers carry the following certifications:
QUICK START GUIDE
125-kHz PROXIMITY CARD READERS
FCC Compliance Statement: This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved could void the user's
authority to operate the equipment.
Product can be used without license conditions or restrictions in all European Union
coun-tries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Spain,
Sweden, United Kingdom, as well as other non-EU countries, including Iceland,
Norway, and Switzerland.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference, including
interference that may cause unde-sired operation of the device.
Cet appareil est conforme à Industrie Canada exempts de licence standard RSS (s).
Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne
peut pas provoquer d’interférences et (2) ce dispositif doit accepter toute
interférence, y compris les interférences qui peuvent causer un mauvais
fonctionnement du dispositif.
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
800-645-5516 • Fax: 631-957-9142 or 631-957-3880 • specotech.com
Speco Technologies reserves the right to change specifications without notice.