Installation
20 EN
09|2017
5.4 Electrical
connection
WARNING
Risk of electric shock due to incorrect connections!
Electrical
connections
must always be carried out by
authorised specialists.
Observe
VDE
and
utility company regulations.
Install pumps for swimming pools and their protection
according to DIN VDE 0100-702.
Install
a
disconnecting device with at least a 3 mm contact
gap per pole to interrupt the power supply.
Protect power supply with a ground fault circuit interrupter,
nominal residual current I
FN
≤
30 mA.
Only use suitable pipe types according to regional
regulations.
Adjust minimum diameter of the electrical pipes to
accommodate the motor output and pipe length.
If
hazardous
situations
can
occur, provide emergency off
switch according to DIN EN 809. The builder/operator must
make a decision according to this standard.
5.4.1 Lightening
protection
device
A lightening protection device is recommended for underwater
motors as protection against atmospheric overloads.
WARNING
Electric shock due to overvoltage!
Build sufficiently dimensioned earth connectors
corresponding to the motor performance and considering
DIN 57100 C62.11 – 1993.
Содержание SUPI
Страница 1: ...DE Originalbetriebsanleitung EN Translation of original operation manual SUPS SUPI...
Страница 3: ...DE DE Originalbetriebsanleitung SUPS SUPI...
Страница 42: ......
Страница 43: ...EN EN Translation of original operation manual SUPS SUPI...
Страница 47: ...Table of contents 09 2017 EN 5 9 Disposal 32 10 Technical data 33 10 1 Exploded drawing 37 11 Index 38...
Страница 81: ...09 2017 39...
Страница 82: ...40 09 2017...
Страница 83: ...41 09 2017...