Special Projects Group SM302 Скачать руководство пользователя страница 1

 
 

 

 
 
 

SM302 

InGaAs Array 

 

Spectrometer 

 

User Manual

 

 
 
 
 
 
 
 
 

1105811 

 

August 2006 

 
 
 
 
 
 

 

Spectral Products

 

 

                2659-A Pan American Frwy., NE  Albuquerque, NM 87107   Tel (505) 343-9700    Fax (505) 343-9705 

www.spectralproducts.com 

1

 

Содержание SM302

Страница 1: ...SM302 InGaAs Array Spectrometer User Manual 1105811 August 2006 Spectral Products 2659 A Pan American Frwy NE Albuquerque NM 87107 Tel 505 343 9700 Fax 505 343 9705 www spectralproducts com 1...

Страница 2: ...2 2 Attaching the SM302 cables 7 2 2 3 Connecting the Spectrometer power supply 7 3 0 OPERATION 8 3 1 SM302 Spectrometer Serial Port Layout 8 3 2 SM302 Spectrograph Optical Layout 9 3 3 SM302 Spectro...

Страница 3: ...m lack of operator attention to proper procedures failure to follow operating instructions unauthorized modifications and natural disasters are not covered under this warranty The SM302 does not conta...

Страница 4: ...is thermoelectrically cooled and temperature stabilized to ensure long term operation stability The multichannel detection with a readout rate of 333 kHz or faster both reduces measurement time and e...

Страница 5: ...ended Only LPF 1300nm 2500nm InGaAs power supply Input voltage 100 120V AC with DB15 connector SM302 spectrograph power supply UL listed 110 220 V power pack meets or exceeds UL1950 CSA 1402C and IEC...

Страница 6: ...2 1 4 Checking System Package Contents Check to make sure that your package contains all of the following components The SM302 system consists of 1 SM302 SM302 EX unit 1 SM302 SM302 EX Power supply N...

Страница 7: ...Remove the computer s cover by removing its mounting screws and sliding off the cover 4 Remove the slot bracket by unscrewing the holding screw and sliding it out Save this screw for securing the boa...

Страница 8: ...3 TxD Data in from computer to Spectrometer 4 DTR Not used with the Spectrometer 5 GND Signal ground 6 DSR Not used in Spectrometer 7 RTS Request to send from computer 8 CTS Clear to send from Spectro...

Страница 9: ...ENTS PER ANGULAR STEP FOR DIFFERENT GRATINGS Lower wavelength scan limit is zero Grating Upper Limit Grv mm nm 1200 1500 600 3000 300 6000 150 12000 75 24000 50 36000 45 40000 3 4 Using the LPF 1300 F...

Страница 10: ...sion you must first remove the LPF1300 knob by loosening the bottom set screw Please make note of the orientation of the knob before removing 2 Remove the two 4 40 screws from the front face of the SM...

Страница 11: ...02 Power Supply To set power supply to run the SM302 standard jumper to R12 is set for 5V JP1 To set the SM302 Extended jumper R4 is set for 6V JP2 Spectral Products 2659 A Pan American Frwy NE Albuqu...

Страница 12: ...NE Albuquerque NM 87107 Tel 505 343 9700 Fax 505 343 9705 www spectralproducts com 12 C Spectrometer Power Supply 1 3 4 5 2 C Grating Selection Pin Dual 1 Common 2 Common 3 5 0V Imin 0 5A Imax 7 0A 4...