5.2 Connections
• No external power sources required for this product
5.3 Setting of the operating parameter
• No customer adjustment available to this unit
5.4 Cleaning
If operated and cleaned correctly your BoilermagXL will give many years of trouble free
filtration with no consumable parts. The filter will remove even the smallest particle due to its
high magnetic filed strength. Cleaning should take no more than a few minutes.
• Turn off the heating system
• Isolate the filter from the system flow
• Using Screwdriver, open the air vent in the top of the filter
• Remove the Drain Plug using Tool provided (see Fig 1 page 11)
• Fully drain contents into a suitable container
• Using the Tool provided, unscrew and remove M8 Domed nuts / Washers
(see Fig 2 page 11)
• Lift the Magnet Cartridge Assembly out of the body and move it away to a cleaning
station (see Fig 3 page 12)
• Non-magnetic contamination will remain in the bottom of the bowl and requires rinsing out
• Remove the Quick release Mesh Plate from the Magnet Core Assembly and rinse clean
(see Fig 4 page 12)
• Using the cleaning tool provided, scrape the bulk of the ferrous contamination off the
magnet core and into a suitable container – it is not essential to remove all of the collected
contamination (see Fig 5 page 13)
• Refit the Mesh Plate to the Magnet Core Assembly
• Re-assemble the Magnet Cartridge Assembly into the body
• Refit and tighten M8 Domed Nuts / Washer
• Refit the Drain Plug
• Close vent
• Remove the Filter isolation
• Carefully open the air vent to release any trapped air
• Close Vent
• Switch on the heating system
Do not use corrosive substances to clean the equipment