![Speakman SE-362 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/speakman/se-362/se-362_installation-manual_1341157003.webp)
Installation
Speakman/SE-362
Speakman Company
• 215-1726 Rev. A; EN 11-09-005
9-6-2011
3
Mounting Hole Locations
7-1/2"
(191)
8-7/16"
(214)
20"
(508)
20"
(508)
6-1/4"
(159)
2"
(51)
2"
(51)
0.47 Dia. Holes
(6) Places
(mm)
22-3/4" (578)
Door
10-1/2"
(267)
8-1/2"
(216)
7"
(178)
26"
(660)
24"
(610)
Nipple
Union Ball
Valve
2" (51)
2" (51)
2" (51)
2" (51)
1" NPT
Outlet
0.28" Dia. Holes
(4) each side,
(8) Total
6-1/2"
(165)
2"
(51)
3/4" NPT
Inlets
5"
(127)
14"
(356)
24"
(610)
Wall
Flange
22-3/4"
(578)
Door
26"
(660)
Bottom View
22-3/4" (578)
Door
10-1/2"
(267)
8-1/2"
(216)
7"
(178)
24"
(610)
Nipple
Union Ball
Valve
2" (51)
2" (51)
2" (51)
1" NPT
Outlet
6-1/2"
(165)
3/4" NPT
Inlets
22-3/4"
(356)
Door
24"
(610)
Side View
Front View
Optional Recessed Cabinet
Optional Surface-Mounted Cabinet
Wall Opening:
24-1/2" W x 24-1/2
"
H