SERVICE INSTRUCTIONS

Service Instructions

Caution- Any repair or servicing of the Valve may effect the maximum outlet temperature 
setting of the Valve. After working on the Valve, make sure the maximum outlet tempera-
ture is set to the recommended setting of 110 °F. 

Cartridge Removal

1) Shut off the HOT & COLD water supplies to the Valve. Remove the Handle Screw & 
Handle. Remove Trim Plate Screw & Trim Plate.
2) With the Valve in the “OFF” position, remove the (4) Valve Bonnet Screws. Carefully 
remove the Bonnet.
3) If necessary, remove the Balancing/Regulating Cartridge from the Valve Body by 
pulling on the Valve Spindle or the Blue Cap of the Cartridge. Make sure the Lower 
Rubber Quad Rings (2) are installed in the bottom of the Cartridge and not in the Valve 
Body.
4) Replace the necessary parts with new parts. When replacing the Balancing/Regulating 
Cartridge, make sure that the Rubber Quad-Rings (2) are properly installed in the recesses 
on the bottom of the Cartridge. These Quad-Rings seal over the hot & cold inlet holes 
inside the body. When replacing the cartridge, make sure the “H” on the cartridge cover 
is on the hot supply side and the “C” on the cartridge cover is on the cold supply side.
5) Make sure the Large Bonnet O-Ring Seal is installed and seated properly in the Valve 
Body. Reassemble the Valve Bonnet, making sure the “UP” on the Bonnet is in the up 
position. Tighten the (4) Bonnet Screws. Turn ON the HOT & COLD water supplies. Check 
valve for leaks.
6) To limit the maximum hot water temperature the valve delivers, adjust the valve’s 
Temperature Limit Stop (TLS) Plate. Slip the Retaining O-Ring and the TLS plate towards the 
end of the Spindle. Rotate the Valve Handle clockwise to the maximum desired hot water 
temperature. Position the TLS plate so it contacts the Lug on the Valve Bonnet and 
therefore restricts the clockwise rotation of the handle. Slip the retaining O-ring back into 
the groove of the Spindle. Turn off the Valve and remove the Handle.
7) Reassemble the Trim Parts, reversing the above procedure.

S-1496-AF / S-1498-LH  REPAIR PARTS

SPEAKMAN

®

RPG03-0371-PC

SPINDLE ASSEMBLY WITH O-RING & WASHERS (NOT SHOWN)

RPG05-0846

BALANCING

 / REGULATION CARTRIDGE (INCLUDES SPINDLE O-RING)

RPG04-0367-PC

HANDLE WITH SCREW

RPG05-0718

4 SCREWS, BONNET, AND BONNET O-RING

RPG49-0005

CARTRIDGE LOWER QUAD RINGS

RPG49-0076

SPINDLE O-RINGS

RPG49-0126

LARGE BONNET O-RING

ITEM NO.

PART NO.

DESCRIPTION

Содержание S-1498-LH

Страница 1: ...mperature 160 F FREEZE PROTECTION Freeze damage to the shower unit will void the Freeze damage to the shower unit will void the warranty It is important to winterize the complete warranty It is important to winterize the complete shower unit The unit must be drained of all water shower unit The unit must be drained of all water in freezing conditions This includes removing the in freezing conditio...

Страница 2: ...2 Slide on the Dial Cap 1 onto the Bonnet Tighten in place with the Dial Cap Screw 2 Slide the Handle 3 onto the Valve post Then tighten with Handle Screw 1 10 Turn on water supplies Turn on Valve to the WARM position and flush for 1 minute 11 OPTION If your unit comes with shower head apply Thread Seal Tape to threads of Shower Arm 1 Thread Shower Head 2 onto Shower Arm 1 and tighten with Adjusta...

Страница 3: ...e cover is on the hot supply side and the C on the cartridge cover is on the cold supply side 5 Make sure the Large Bonnet O Ring Seal is installed and seated properly in the Valve Body Reassemble the Valve Bonnet making sure the UP on the Bonnet is in the up position Tighten the 4 Bonnet Screws Turn ON the HOT COLD water supplies Check valve for leaks 6 To limit the maximum hot water temperature ...

Страница 4: ...eters TO FLOOR 19 3 4 504mm 7 1 8 180mm 5 1 2 140mm 1in 25 4mm 6in 146mm SIDE VIEW WITH WALL PIPE STRAP W SCREWS LOCATION OPTIONAL FRONT VIEW WITHOUT WALL S 1498 LH ROUGH IN DIAGRAM SPEAKMAN DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE NOTES COMPLIANCE CONNECTIONS ASME A112 18 1 CSA B 125 1 Inlet NPT Female Outlets NPT Male Contractor to supply necessary inlet connections 1 25 4mm 5 3 4 146mm 4 3 1...

Отзывы: