Speakman S-1496-AF Скачать руководство пользователя страница 3

11

Turn on water supplies. Turn on Valve to the 
"WARM" position and flush for 1 minute.

12

OPTION:

 If your unit comes with shower head, 

apply Thread Seal Tape to threads of Shower Arm (1). Thread 

Shower Head (2) onto Shower Arm (1) and tighten with Adjustable Wrench. Check all connections for leaks.

NOTE:

 Shower head not

included with all models.
Shown for reference only.

SERVICE INSTRUCTIONS

SPEAKMAN

®

Service Instructions

Caution- Any repair or servicing of the Valve may effect the maximum outlet 
temperature setting of the Valve. After working on the Valve, make sure the 
maximum outlet temperature is set to the recommended setting of 110 °F. 

Cartridge Removal: see STEP 8.

1) Shut off the HOT & COLD water supplies to the Valve. 

2). Remove Valve Handle and the Dial Plate as outlined in 

STEP 3

.

3) With the Valve in the “OFF” position, remove the four (x4) Valve Bonnet 
Screws. Carefully remove the Cartridge Assembly. Ensure nothing is left over 
in the Valve Body cavity.

4) Replace with new Cartridge Assembly. Make sure the Large Bonnet 
O-Ring Seal is installed and seated properly in the Valve Body. Reassemble 
the Cartridge Assembly, making sure the “UP” on the Bonnet is in the up 
position. Tighten the four (x4) Bonnet Screws. Turn "ON" the HOT & COLD
water supplies. Check the Valve for leaks.

5) To limit the maximum outlet temperature the Valve delivers, 

see STEP 9

.

6) Reassemble the Dial Plate and the Handle as outlined in 

STEP 10

.

S-1496-AF / S-1498-LH  REPAIR PARTS

SPEAKMAN

®

RPG04-0367-PC

HANDLE WITH SCREW

RPG05-106096

RETROFIT "PB KIT

ITEM NO.

PART NO.

DESCRIPTION

Отзывы: