Speakman S-1495-AF Скачать руководство пользователя страница 1

INSTRUCTIONS FOR MODELS

92-S-1495-97-03

For additional assistance or service please contact:

SPEAKMAN

®

800-537-2107

[email protected]

www.speakman.com

S-1495-AF

S-1497-LH

* Shower head may
vary between models.

HELPFUL TOOLS & SUPPLIES:

TOOLS AND SUPPLIES

Pencil

Adjustable

Wrench

Flat Tip

Screwdriver

Thread Seal

Tape

3/32" Hex Key

Wrench

(Included)

1/2”

 Hex Key

Wrench

(not included)

Phillips

Screwdriver

Measuring

Tape

Safety

Glasses

Level

Warranty information can be found at: 
www.speakman.com

WARRANTY

Your new Shower/Bath Valve is designed for years 
of trouble-free performance. Keep it looking new by 
cleaning it periodically with a soft cloth. The use of 
harsh chemicals and abrasives on any of the 
Speakman custom finish products may damage the 
finish and void the product warranty. Please be sure 
to only use approved cleaners. Please contact 
Speakman for any clarification of acceptable 
cleaners.

This type of valve must be cleaned and maintained 
on a regular basis. Periodic maintenance should be 
performed at least every 12 months or after any 
changes have been made to the building’s plumbing 
system. Valves that are installed outdoors should be 
winterized by removing all of the internal parts and 
removing any standing water from the valve. 
Quarterly the maximum hot temperature setting (TLS) 
should be checked and adjusted accordingly. 

MAINTENANCE

Cover your drain to prevent loss of parts. Be sure to 
wear eye protection while cutting pipe.

SAFETY TIPS

IMPORTANT

• Be sure to read instructions thoroughly before  
   beginning installation.

• Be sure to have properly adjusted the Temperature  
   Limiting Stop (TLS) as outlined in this Installation  
   Manual.

• Inspect all connections after installation of valve.

• This valve has an operating range of 

20-80 Psi.

• This valve is designed to be used in conjunction  
   with a shower head rated at 

1.75 gpm (6.6 L/min)

  

   or higher flow rate.

NOTE:

 This installation manual covers several  

   models of valves. While the appearance of your  
   valve may differ from those shown, the installation  
   method is the same.

Maximum water pressure: 125 psi static; minimum  

   water pressure: 20 psi flowing; minimum cold     
   supply temperature: 40 °F; maximum hot supply  
   temperature: 160 °F;

FREEZE PROTECTION

Freeze damage to the shower unit will void the 

Freeze damage to the shower unit will void the 
warranty. It is important to winterize the complete 

warranty. It is important to winterize the complete 
shower unit. The unit must be drained of all water 

shower unit. The unit must be drained of all water 
in freezing conditions. This includes removing the 

in freezing conditions. This includes removing the 
valve cartridge and the shower head from the unit. 

valve cartridge and the shower head from the unit. 
Store the valve cartridge and shower head indoors.

Store the valve cartridge and shower head indoors.

• Mounting location must be capable of supporting 
the product in use.

CAUTION:

When outdoor temperature

rises above 90 degrees, use caution to
prevent scalding from water stored within
the unit. It is recommended to flush the unit
by turning it on for 30 seconds before
entering the shower water. This will avoid
accidental scalding by the user and ensure
safe use of the shower unit.

1

Install the HOT and COLD supply lines for the
Valve, either through the wall, from the ceiling,
or from the floor. For ceiling and floor mounts,
hold 1” from finished wall to center of supply
lines. See rough-in diagram on last page.

1/2” NPT
CONNECTION

2

Disassemble the two Union Stops. Start by 
loosening the Union Nut (1). The Union Adapter 
(2) and Union Washer (3) usually stay affixed
to the Union Nut. Set the Union Body (4) aside for 
later use.

X2

3

If the components in Step 2 did not stay
together, insert the Union Adapter (2) into the
Union Nut (1), followed by the Union Washer(3).
After applying Thread Seal Tape to the Union
Adapter, thread the assembly into the COLD
Inlet. Tighten with a 1/2” Allen Wrench. Repeat
for HOT Inlet.

X2

1/2"

4

Retrieve the Union Body. After the application of 
Thread Seal Tape, thread the Union Body onto the 
COLD supply line and tighten with the Adjustable 
Wrench. The outlet of the Union Body should be 
aligned horizontally. Repeat for HOT supply line.

X2

5

Slide the Strap (1) onto the Shower Arm (2).

6

Apply Thread Seal Tape to both ends of Shower
Arm Gooseneck, and Bottom Plug. Thread
Shower Arm Gooseneck into Valve Body being
sure to properly align outlet. Install Plug into
bottom port of Valve Body and wrench tighten.

7

Insert the Valve Assembly between the installed
Union Stop Bodies. Thread Union Nuts onto Valve
Body and wrench tighten, being sure Shower
Arm Gooseneck is in a true vertical position.

Turn 

"ON"

 water supply and check for leaks. 

See 

Service Instructions

 for turning 

"ON"

/

"

OFF

"

 water supply.

8

Mounting location is optional.

Verify that the 

mounting location and structure is capable of 
supporting the product in use. 

Mark location of mounting holes for Shower Arm 
Strap (1) referencing the rough-in diagram 
contained in this document.

Install 

Shower Arm Strap

 (1) to upper pipe using 

Supplied Screws. In drywall or tile applications, 
be sure to use appropriate hardware.

Отзывы: