MAINTENANCE
The valve and the eyewash aerators are the only portions of the unit that may require maintenance. Should
you need parts to repair this unit, please reference the parts listing below for correct part numbers. Before
any maintenance is done be sure to shut the water supply off.
ROUGH-IN
FLOW DATA
EYEWASH:
FLOW PRESSURE PSI (BAR)
15 (1)
FLOW RATE GPM (LPM)
3 (11)
REPLACEMENT/REPAIR PARTS
ITEM PART/GROUP
#
DESCRIPTION
1
RPG05-0714
Aerated Bull Horn Assembly
2 31-0546
Eyewash
Arm
3
RPG05-0603
PERFECT Valve (Not Shown)
3
RPG05-0604
PERFECT Valve- Left Hand (Not Shown)
4
45-0678
Flat Steel Washer
5
01-0412-MO
½” – 14 NPSM Locknut
6
G20-1940-RCP
½” Volume Regulator
7
RPG05-1177
Aerator Replacement Group (6 Each)
8
RPG38-0379
Aerated Sprayhead Assembly (4 Each)
9
RPG07-0104
Flip Top Dust Cap Replacement (20 Per Bag)
WARNING: Use only genuine Speakman parts when repairing or replacing components
.
To order parts call 1-800-537-2107.
Note: All units meet existing ANSI Z358.1 Standards and OSHA Rules. Product
improvements may cause specification and dimensional changes without notice.
Note: All units meet existing ANSI Z358.1 Standards and OSHA Rules. Product
improvements may cause specification and dimensional changes without notice.
Note: All units meet existing ANSI Z358.1 Standards and OSHA Rules. Product
improvements may cause specification and dimensional changes without notice.
NOTE: This unit should be connected to an uninterrupted
source of potable water, with a minimum flowing pressure