![Speakman Commander SC-3049 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/speakman/commander-sc-3049/commander-sc-3049_installation-operation-and-maintenance-instructions_1341169001.webp)
08/08
92-1902-R6
SPEAKMAN COMPANY
SC-3001 thru SC-3049 Installation, Operation, & Maintenance Instructions
COMMANDER® WIDESPREAD LAVATORY COMBINATION
DESCRIPTION
Speakman polished chrome plated COMMANDER widespread lavatory combination with PERFECT® valves. 1/4 turn ceramic
cartridges covered by a 25 year Silver warranty. Vandal-resistant handles with color- coded indexes. Brass gooseneck
(swivel or
rigid)
or brass cast spout. Hard pipe installation. Accommodates decks/counter tops up to 1-1/2” thick. Vandal-resistant water
conserving aerated outlet device reduces flow to 2.2 GPM/8.4 LPM to meet existing ASME A112.18.1/CSA B125.1 Standard.
SPECIFICATIONS
SUPPLY: ½”-14 NPSM Compression Coupling or 1/2” Copper Sweat Connections
FLOW RATE: 2.2 GPM/8.4 LPM (MAX)
SHIPPING WEIGHT: 5.5 LBS. (SC-3004-LD)
OPTIONS
INSTALLATION INSTRUCTIONS
Important- if installing an optional VB8/6 Rigid vacuum breaker spout and space is limited between deck fitting holes and
backsplash/wall, install the spout to the flange assembly at this time (See Step 6)
1)
Remove the compression nut from the outlets of the end body valves. Remove the compression sleeves and tee assembly
from the tee assembly bag group. Slide one (1) compression nut and then one (1) compression sleeve over the copper pipe at
both ends of the tee assembly. Bench assemble the tee to the Hot/Cold end body valves. Be sure to push the copper piping
completely into the outlets of the valves. While holding the tee and compression sleeves in place, hand tighten the
compression nuts to the end bodies.
Make sure the valves are perpendicular to the tee assembly.
2)
Insert and position the gooseneck flange or center spout with gasket down through the center hole of the sink or counter top.
From
under the sink, apply gooseneck flange/center spout hardware by sliding the spacer and channel washer onto the
threaded shank. Screw the shank nut halfway, not completely, up the shank.
NOTE: Hole on top of gooseneck flange
should face towards the front. Slot in flange gasket should face towards the back for lift rod hole applications.
3)
Loosen the setscrew and remove the end body valve flange nuts and rubber washers. Screw the locknuts and cup washers
down on end body valves. From below the counter top, push the end body with tee assembly up through the outer holes in the
sink or counter top.
NOTE: Blue colored end body (COLD) should be on the right side of tee assembly, Red colored
end body (HOT) on the left.
Hand tighten the tee assembly’s swivel nut to the shank of the gooseneck flange or center
spout. While lifting the end body with tee assembly up by its spindles, replace the rubber washers and screw the flange nuts
back onto the end body valves, with flat side up, till they are flush with the tops of the 1-1/8”-16 UN threads
(See Rough-In on
back side of sheet).
Tighten the setscrew to lock the end body valve flange nuts into position. Let the end body with tee
assembly rest on the flange nuts. From below, wrench tighten the gooseneck flange/center spout shank nut with channel
washer/spacer, tee swivel nut , end body valve locknuts with cup washers, and two (2) tee compression nuts at the outlets of
the end body valves to secure the entire unit and prevent leaks.
NOTE: DO NOT OVERTIGHTEN THE TEE SWIVEL NUT.
4)
Connect water supply lines to inlets
(1/2”-14 NPSM male threads)
of the end body valves and wrench tighten coupling nuts to
prevent leaks.
5)
From above the sink, screw trim onto end body valve assemblies and hand tighten. Slip trim sleeves onto spindles. Position
handles and screw onto spindles. Position index buttons on handles and press into place. If applicable, assemble gooseneck
to flange assembly by wrench tightening gooseneck collar nut.
NOTE: For rigid gooseneck, place locking washer from
hardware bag group into flange outlet before assembling gooseneck.
6) For Rigid Vacuum
Breaker Spout- VB6/8 (Less “SW” option):
Make sure the locking washer is removed from flange outlet.
IMPORTANT
- Install rigid adapter into flange and wrench tighten
(See Rough-In on back side of sheet)
. Apply thread
locker/sealant to the spout tapered pipe threads. Screw the spout into the adapter until the threads start to get snug.
NOTE:
When positioning the spout, hold adapter hex with a wrench so flange does not rotate
. Tighten the spout at least 1/3
turn to the proper position
(Do not over tighten spout).
Remember that the thread locker/sealant will lock and seal the spout
assembly in place.
7)
With drain installed
(see drain instructions)
, turn water supplies on and flush both hot and cold sides of faucet. If applicable,
install outlet device. Check all connections for leaks.
◊
BO – Vandal-Resistant 0.5 gpm Flow
Control Device
◊
LF – Vandal-Resistant Laminar Flow
Control Device (2.2 gpm)
◊
VB6 – 6” Deep Spread Rigid Gooseneck
Spout with Vacuum Breaker
◊
FC – Laminar Flow Plain End
Gooseneck Spout (2.0 gpm)
◊
GB – Vandal-Resistant 1.5 GPM
Aerator Outlet Device
◊
VB8 – 8” Deep Spread Rigid Gooseneck
Spout with Vacuum Breaker
◊
D75 – Diamond 75 Escutcheons
and Handles
◊
SO – Rose Spray Outlet Device
(Gooseneck Spout Only)
◊
4 – 3-3/4” Deep Spread Gooseneck Spout
◊
CWO- Cold Water Only
(Only available
w/ FH Option)
◊
TWI – Tee w/Extra Inlet Port
(Only
available w/ FH Option)
◊
8 – 8” Deep Spread Gooseneck Spout
◊
HS – Hose & Spray
(Only available w/
FH Option)
◊
ST – Serrated Tip
(For VB6/8 only)
◊
9 – 9” Deep Tubular Swing Spout
◊
LD – Less Drain
◊
SW – Swivel Spout
(For VB6/8 only)
◊
12 – 12” Deep Tubular Swing Spout
◊
MI – Metal Indexes
◊
FH – Stainless Steel Flex Hoses
(For