SpeakerCraft RSA-1.0 Скачать руководство пользователя страница 2

RSA-1.0 Installation Instructions  

 

 

 

                       Page 2

J6

J1

ASW1

D4

D5

J4

J5

J2

J3

U4

U2

U5

U1

U7

SW1:1

U6

U3

RSA-1.0

RS232 Interface Adapter

SpeakerCraft

®

CONTROL

PORT

EXPANSION

PORT                  LOOP

RS232 

DATA I/O

IR 

IN

0 12

34

56

789AB

C

D

E F

ADDRESS

HI                       LO

PROGRAMMING

IR

OFF                      ON

12VDC

Top

ASW1

SW1:1

1“

ACTIVITY

POWER

Front

ASW1

SW1:1

1

2

3

4
5

6

7

8

9

10

11

2.125“

4.3”

Rear View

RSA-1.0 FEATURES

1.  RS232 DATA I/O - 

DB9M terminal connects to the de-

vice being controlled via RS232 using a DB9 cable.

2. ADDRESS 

SWITCH 

16 position rotary switch, sets de-

vice address allowing up to 16 RSA’s to be used in a single 
system.

3.  12VDC POWER JACK - 

2.1mm coaxial jack connects to 

a SpeakerCraft PS-1.0 Power Supply for power.

4. PROGRAMMING 

SWITCH 

Two-position switch gets set 

to ON position for updating the fi rmware from EZ-Tools.

5.  IR HI/LO SWITCH - 

Two-position switch sets the IR 

IN level. Set to HI when connected to a high IR output 
device, (12V; P-P) set to LO when connected to a low 
output device, (5V; P-P).

6. POWER 

LED 

Red LED illuminates when RSA has DC 

power and completes its internal initialization.

7. CONTROL 

PORT 

4-circuit, 3.5mm mini-jack connects to 

PC running EZ-Tools for RSA programming and fi rmware 
updates.

8.  EXPANSION LOOP -  

RJ45 jack primarily used to connect to the 

Expansion Port

 on additional RSA-1.0(s) when mul-

tiple RSA-1.0’s are used to control multiple RS232 devices in a single system. The 

Expansion Loop

 and 

Expansion Port

 

jacks are parallel. Up to 16 RSA-1.0’s can be used in a single system.

9.  EXPANSION PORT - 

RJ45 jack primarily used to connect to the 

Expansion Port 

or 

Loop

 on a SpeakerCraft MZC-66 

or MZC-88. This connection receives control data from the MZC via RS485. RS232 commands are confi gured in the MZC 
using EZ-Tools.

10. IR  IN  - 

3.5mm mini jack receives SpeakerCraft EZ-Code IR commands from an IR control system. These commands are 

converted to RS232 commands as associated in EZ-Tools. This jack only functions when the special IR to RS232 Control 
Interfacing Firmware has been programmed into the RSA.

11. ACTIVITY  INDICATOR  - 

Green LED fl ashes to indicate activation of internal command data.

Figure 1
RSA-1.0 Features

INTRODUCTION

The SpeakerCraft RSA-1.0 Remote Serial Adaptor provides control of RS232 compatible devices from SpeakerCraft MZC-66 and 
MZC-88 A/V Amplifi er/Controllers. It connects to an MZC rear panel Expansion Terminal and is triggered by EZ-Pad Button 
presses or remote EZ-Code IR commands (when used to control an MZC-66 or 88). The RS232 Commands are programmed 
into MZC Projects using EZ-Tools Programming Software. RS232 commands are stored in the EZ-Tools Command Library and 
programmed to keypad buttons using a similar procedure to programming IR commands. New RS232 commands, of up to 
100 characters each, can be added to the Library in EZ-Tools via ASCII or HEX data entry.

Up to 16 RSA-1.0s can be used in a single system by setting each RSA to a unique device Address. A data buss can be created 
to ‘daisy chain’ the RSAs for ease of installation and connection.

Содержание RSA-1.0

Страница 1: ...INSTALLATION INSTRUCTIONS RSA 1 0 Remote Serial Adaptor...

Страница 2: ...and Expansion Port jacks are parallel Up to 16 RSA 1 0 s can be used in a single system 9 EXPANSION PORT RJ45 jack primarily used to connect to the Expansion Port or Loop on a SpeakerCraft MZC 66 or...

Страница 3: ...are RS232 protocol which has a limitation of about 50 feet between devices For best performance try to install the RSA 1 0 s as close to the device s being controlled as possible When using multiple R...

Страница 4: ...nitial release of the RSA 1 0 will only allow programming and interfacing with SpeakerCraft MZC 66 88 Multi Zone Controllers The following Programming Instructions detail the steps required to program...

Страница 5: ...on to indicate that the RSA has been selected for programming If multiple RSAs are being used in a system this will indicate which RSA has been selected 10 Left click the CMD Library Tab to bring the...

Страница 6: ...anufacturer s tech support to get this information In some cases the EZ Tools CMD Library will already have IR codes or possibly some RS232 Commands for a particular Brand Component and Model and all...

Страница 7: ...confirm that the command string has been properly sent received and executed 13 In the Response Settings box select the appropriate Response Timeout from 0 0 to 10 0 seconds This will determine the a...

Страница 8: ...work 2 x RJ45 RS232 DB9M Control Port 3 5mm mini jack 4 circuit RS232 Parameters Baud Rate 300 1200 2400 4800 9600 19200 38400 57600 Selectable Data Bits 7 8 Selectable Stop Bits 1 2 Selectable Parity...

Страница 9: ...chaser within a reasonable time freight prepaid This Warranty does not include service or parts to repair damage caused by accident disaster misuse abuse negligence inadequate packing or shipping proc...

Страница 10: ...RSA 1 0 Installation Instructions Page 10 940 Columbia Avenue Riverside CA 92507 800 448 0976 Fax 951 787 8747 www speakercraft com LIT07105...

Отзывы: