Страница 1: ...Operating Instructions S Thermatik NEO ...

Страница 2: ...ners we offer you first class products that will touch your customers emotionally and will inspire feelings such as a feeling of security safety and comfort To achieve this we recommend that you read the operating instructions carefully in order to get a quick and comprehensive overview of your decorative fireplace In addition to the information on operation this manual also contains important car...

Страница 3: ...st 10 7 Power failure 11 8 Service menu 11 9 Closed loop control characteristics 12 10 App 13 11 Notes for stoves 14 12 Guide 15 13 General warranty conditions 16 13 1 Area of application 16 13 2 General information 16 13 3 Warranty period 16 13 4 Warranty requirements 16 13 5 Exclusions from the warranty 16 13 6 Elimination of defects repair 17 13 7 Extension to the warranty period 17 13 8 Spare ...

Страница 4: ...the same time This is the only way of ensuring that the Differential temperature function can be implemented together with the S Thermatik NEO Temperature sensor PT1000 part no 1013765 Length 3 metres incl immersion sleeve with a G1 2 external thread 1 GENERAL INFORMATION You have decided in favour of a Spartherm fireplace insert accessory thank you for your confidence in our company This manual p...

Страница 5: ...y of combustion air is directed into the appliance The time for adding fuel is displayed with a visual as well as an audible signal The control system remains active until the flue gas temperature has dropped to about 50 C and then it returns to Standby mode In the event of a power failure the air slider automatically moves into a position in which the fire area can continue to be operated Until p...

Страница 6: ...nction of the combustion control system may be checked at any time with the air control lever Every time the firebox door is opened the air control lever must move to the right to the combustion air fully open position The specified factory settings which are required for the safe operation of the combustion control may not be changed The installed wires on the fireplace insert must not be pulled ...

Страница 7: ...ess Here is a key to the 6 points Standby ignition rising temperature falling temperature time to add fuel that is the small point glow phase The flame symbol can be used to select a small normal big burnup The fire area then receives less or more combustion air respectively 3 3 GENERAL OPERATION OF THE DISPLAY There is a BACK button at the top left of each menu window to enable you to go back one...

Страница 8: ...CK button 2 Name of the menu 3 Scroll keys 4 Function 5 Setting controller 6 Operating knobs Sliders can be adjusted by fingertip control or by holding and sliding the round knob The control knobs can be moved by touch or by sliding them gently to the left or right If the knob is backlit in red the selected function is enabled Note The active surface of the scroll keys is larger than shown on the ...

Страница 9: ...ly become available in the early part of 2018 Display Here among other things is the Screen Saver sub menu Here you can choose the brightness level you wish to have for the screen saver If you choose several temperatures these will be displayed at 7 second intervals If you pull the brightness controller all the way to the left the display will go dark The screen saver switches on automatically abo...

Страница 10: ...es disconnected from mains power once mains power has been restored To conduct this self test the fire area must be cold flue gas temperature below 50 C and all fire doors must be closed 1 Switch the combustion control off pull out the power plug 2 Switch the combustion control on again insert the power plug 3 The air control lever moves to the right up to its 100 open limit stop With stoves the f...

Страница 11: ...tures the lever only moves to the right After that the control system resumes normal operation 7 POWER FAILURE The S Thermatik NEO is equipped with a special function Whenever there is a power failure the air slider automatically moves into a safe position about 50 60 In this position the fire area cannot overheat but it can continue being operated manually You can also allow the fire to be exting...

Страница 12: ...h the ensuing burnup the system then switches to the preselected stage The acoustic signal to add more fuel only sounds once when the time to add more fuel is reached for the first time After that this signal is not repeated In Manual mode there is no progress bar and no selectable heating capacity Whenever the door is opened the air control lever moves to 100 stays there for one minute then retur...

Страница 13: ...ed in the Service menu System Bluetooth This can prevent unauthorised accesses or overlaps The factory setting is 0000 10 APP For the S Thermatik NEO there is an app for devices with an Android or an IOS operating system This app goes by the name of S Thermatik NEO and it can be downloaded from the Play Store or from iTunes To install this app you need to enable Bluetooth on your device and you ma...

Страница 14: ...e LEDs light up about 1 x per second and about 2 x per second in the fast flashing mode Even on control systems without a display it is possible to connect to the appliance using the app and Bluetooth The standard password for the Blue tooth connection is 0000 On stoves a mechanical Auto Manual control knob is usually installed in the lower section of the appliance This should always be set to Aut...

Страница 15: ...the rotary vane discs Check the parameter setting does the current parameter set match the device Check the air control lever mechanics for looseness 12 GUIDE The S Thermatik NEO burnup controller detects the most significant errors automatically and displays these in the form of clear text messages Motor errors are detected whenever the motor fails to move in response to a movement command Errors...

Страница 16: ...of the coating or galvanic surfaces due to excessive thermal loading or over heating The vertical sliding mechanism Failure to comply with installation guide lines resulting in over heating of the guide rollers and bearings 13 GENERAL WARRANTY CONDITIONS 13 1 AREA OF APPLICATION These standard warranty terms apply for the contractual relationship between the manufacturer Spartherm Feuerungstechnik...

Страница 17: ...ace the device free of charge The elimination of defects shall take precedence The terms of this warranty shall not extend to any damage or compensation not covered by statutory provisions 13 7 EXTENSION TO THE WARRANTY PERIOD The warranty period shall automatically be extended where claims made in respect of these warranty provisions result in the repair or replacement of defective equipment 13 8...

Страница 18: ...Electromagnetic Compatibility 2014 30 EU EMC Wireless systems directive 2014 53 EU RED We Spartherm Feuerungstechnik GmbH Maschweg 38 49324 Melle Germany hereby declare that the products listed below comply with the above EU Directives Product type Combustion control Model S Thermatik NEO Melle 11 01 2017 Gerhard Manfred Rokossa CEO ...

Страница 19: ...GB GB 19 NOTES ...

Страница 20: ...u salón Het merk van wereldformaat voor uw woonkamer Światowa marka do Państwa salonu Торговая марка 1 для Вашего дома D Ihr Fachhändler UK Your specialist dealer F Votre revendeur spécialisé IT Il vostro rivenditore specializzato E Sus comercios especializados NL Uw vakhandelaar PL Państwa sprzedawca РУС Ваш дилер Spartherm Feuerungstechnik GmbH Maschweg 38 49324 Melle Germany Tel 49 5422 9441 0 ...