![Spartz MATRIX-X1616 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/spartz/matrix-x1616/matrix-x1616_manual_1340323004.webp)
www.spatz-tech.de
4.1.0 IR-Commands
Power
The unit has discret ON and OFF comands.
Input selection
The
INFO
button starts the sequence. In the OUT1 display
you will see (o), now type the number of output (zone) you
want to assign a new input. The number will be displayed in
the OUT2 display. Next step is pressing the
MODE
button, you
will see (i) in OUT3 display, now select the new input with the
number keys. To make the switch press the OK button.
PRESET Selection
To Select any of the 16 PRESETs press the
F1
button. You will
see a (P) in OUT1 display, now press the number keys,
e.g. F1 -> 1 -> 2 = PRESET 12
Press OK button to activate the new PRESET.
Arrow buttons
The arrow buttons have the same functionality as arrow
buttons on the front of the unit.
4.1.1 General operation
You may fully operate and configure the
MATRIX-X1616
from the front panel. Configuration of EDID
information is possible using the arrow buttons and STORE button. There are 3 main submenus that can be
reached using the right arrow button and then the UP and DOWN button.
There are EDID. MANAG. GROUP, DEVICE GROUP or SYSTEM GROUP. Using the right button again will lead
you in the next submenu. UP and DOWN button will cycle through the possbile settings. Using the right
button will initiate a blinking cursor indicating the you can now change the setting using UP or DOWN
button.
If you want to permanently store your setting do not forget to press the STORE button.
You may leave the submenus using the LEFT button.
The main display will show firmware version and in the upper right corner which remote configuration is
currently active.
Input selection for Output
We have spent each output its own display so you have a complete overview of the switch configuration.
Each output has an UP and DOWN button to change the input assignment.
The matrix will automatically recognize the number of input and output cards and only display available
outputs. e.g. if there are 3 output modules installed only OUT1-OUT6 are active.
Only inputs that are present will be selectable, e.g. if there are 4 input cards installed you may only cycle
through input 1-8.
Recalling PRESETs
The Matrix has 16 PRESET memories that can be recalled easily by simply pressing the PRESET button and
then one of the up/down buttons of the OUT 1-16 displays. The OUT 1-16 refer to the PRESET 1-16.
Simple as that.
To STORE a new switch configuration in a PRESET, press the PRESET button and then the STORE button.
You may now memorize the active switch configuration to one of the 16 PRESETs by using the up/down
button of one of the OUT 1-16.
e.g. to STORE your configuration in PRESET 2, press PRESET button then STORE button then either UP or
DOWN button from OUT 2. Done !