8.  MAINTENANCE

 

 

 

 

WARNING!

  

 

Before performing any maintenance or repairing of device, it should be disconnect from the 

power source and wait at least 5 minutes. The voltage accumulated in capacitors should be 

discharged at this time to a safe level. But even after that operation you should be careful.

 

  

Maintenance and repair work may be performed only by qualified personnel with the appropriate per-

missions. Regular maintenance provides adequate service life and trouble-free operation of the device.

Daily (before each use/installation):

•  Perform a visual inspection of the housing, knobs, control panel.
•  Inspect (visual inspection) the power cord and power plug. Check the insulation of the cable.
•   Check the condition of cables and their connectors. If cable insulation is damaged – replace 

it. If connection is not tight – press the plug.

•  Check if the cooling fan is working properly.
•  Make sure that all vents are not obstructed.
•   Check the elements blocking air preparation. If necessary, drain excess condensate  

from the filters. 

•  Check the technical condition of the plasma torch and consumables.

At least once a month:

•   Regularly remove dust from inside the machine using compressed air. The pressure should 

be low enough so as not to damage small parts inside the device. If the dust level is high in 

the workplace, clean the machine more often.

•   Check the connection of internal electrical components. If anywhere the joints are not tight 

– tighten them.

Once a year:

•   You should send device to an authorized service center for an interim review.

9.  ENVIRONMENTAL PROTECTION

The product must not be disposed of into an ordinary waste container. It is totally 

forbidden to dispose of electric or electronic equipment marked with a crossed-

-out trash can symbol by throwing it into ordinary waste containers.  According 

to the WEEE directive (directive 2012/19/UE), binding within the European Union, 

such products should be disposed of according to local regulations.
We hereby inform the client that, according to the regulations, each commodity 

is burdened with waste disposal costs (WDC) according to charging rates valid for a given year.

Attention!

 If using liquid to water-cooled torches, utilize it according to attached information. 

Содержание EasyCUT 40E

Страница 1: ...User s manual Plasma cutter SPARTUS EasyCUT 40E 40E Compressor...

Страница 2: ...nd performance during realization of the above mentioned processes SPAR TUS products are characterized by precisely such features they are primarily reliable and durable but they are also versatile We...

Страница 3: ...s 6 1 8 Other informations 6 1 9 Extra precautions 7 1 10 Symbols used in instructions 7 2 ELECTROMAGNETIC FIELD EMF 7 3 ELECTROMAGNETIC COMPATIBILITY EMC 8 3 1 General informations 8 3 2 Assesment of...

Страница 4: ...ding operations are expected to be carried out All equipment should be placed so that it does not present a hazard in passageways on ladders or stairways etc Falling objects can cause injuries or kill...

Страница 5: ...n dazzle and impair vision infrared heat radiation can damage skin and eyes Such radiation can be direct or reflected from surfaces such as bright metals and light colo ured objects 1 3 1 Eye and face...

Страница 6: ...haust draught to keep vapours and gases away from the breathing zone When welding is carried out in a confined space operators should only be permitted to weld when other persons who have been instru...

Страница 7: ...and located in an easily accessible place The surroundings of the work should be observed for an adequate period after its termination Hot spots and immediate surroundings should be observed until the...

Страница 8: ...nce in an uncontrolled manner The welding wire tip may be sharp Never aim the burner tip of the welding torch at your face eyes or other people 1 7 4 Moving elements can be dangerous All protective el...

Страница 9: ...use this symbol to pay your attention about important information 2 ELECTROMAGNETIC FIELDS EMF Electric current flowing through any conductor causes localized electric and magnetic fields EMF All weld...

Страница 10: ...arc welding equipment the user shall make an assessment of potential elec tromagnetic interferences in the surrounding area The following shall be taken into account a other supply cables control cab...

Страница 11: ...cer with air filter which is mounted at the rear of the ca sing in a place specially designed for that purpose protection against damage eg during the move CUT 40E device has a lot of modern solutions...

Страница 12: ...ty of work is turned off abnormal indicator on front panel lights up In such a situation You should not turning off the unit immediately Wait some time until fan cools the unit Time to return to the s...

Страница 13: ...aining took place and or gained experience to perceive the risk and avoid hazards during use of the product IEC 60204 1 7 1 PROPER COOLING The unit should be placed stable on a dry and flat surface Av...

Страница 14: ...ssible range of mains voltage fluctuations etc are given in the table with technical parameters of device and on the rating plate of cutter Before connecting the unit to the power source Check whether...

Страница 15: ...block and to the device 3 Connect properly the air hose to the input terminal 8 see 7 3 4 Make sure that there are no leaks 5 Carefully unscrew the valve in the regulator 10 see 7 3 6 To regulate the...

Страница 16: ...USING Control cable Work clamp Power cable Compressor Plasma torch Air filter with the pressure control on the device max 8 bar Elements of air filtration and air preparation in installation Cutting...

Страница 17: ...CUT 40E 40E Compressor are equipped in standard with system of contactless arc ignition with HF high frequency generator There is no need for the nozzle tip to contact the surface to ignite the plasma...

Страница 18: ...20 Microswitch 4 52531 Electrode 5 60028 Swirl ring 6 51316 06 Tip 0 6 51316 Tip 0 8 51316 09 Tip 0 9 7 60389K1 Shield cap 1 hole 60389K Shield cap 2 holes 60389K4 Shield cap 4 holes for EasyCUT 40E C...

Страница 19: ...sate from the filters Check the technical condition of the plasma torch and consumables At least once a month Regularly remove dust from inside the machine using compressed air The pressure should be...

Страница 20: ...does not respond Poorly connected to the supply voltage Failure of power switch PLASMA CUTTING PROBLEMS Oblique or too wide kerf Worn nozzle Worn electrode Unstable intermittent plasma arc Too low com...

Страница 21: ...Notes...

Страница 22: ...Notes...

Страница 23: ...igh quality production excellentparametersandergonomics thesearefea turesoftheSPARTUS Masterseriesofdevices which werecreatedwithdemandingweldingjobsinmind Precision functionality excellent parameters...

Страница 24: ...Videopresentation of products Subscribe to the channel SPARTUS INFO...

Отзывы: