background image

GB

GB

 25

5.4 LIGHTING A FIRE / BURNING WOOD

Lighting the fire in your fireplace cassette is very easy if you follow the 
instructions given below:

1.  A fire may only be started in the fireplace cassette when the firebox 

lining has been correctly installed.

2.  Turn off any air extraction ventilation (kitchen, bathroom, WC etc.). This 

will avoid low pressure building up in the installation room that can 
affect the extraction of flue gasses from the fireplace. Check the com-
bustion air supply (if required, open the cover flap)!

3.  Adjust the combustion air regulator to the “Air supply open (A)” position 

and open the firebox door (swing open).

4.  Place chopped wood into the middle 

of the firebox using the funeral pyre 
method (use softwood). 

Caution:

 The height of the wood pile 

must not exceed the lower marking on 
the deflector plate!

5.  Place standard firelighter cubes under 

the wood pyre to help start the fire. (paper is not recommended because 
it burns too quickly and causes ash to circulate).

6.  Never use methylated spirits, petrol, oil or other easily combustible 

liquids.

7.  Light the fire using the firelighter cubes and, if required, leave the fire-

box door open by approx. 3-5 cm. The fire should now light, burning 
brightly and intensively.

8.  When the kindling wood is burning well, add 

smaller hardwood logs or larger softwood logs 
using the funeral pyre method and close the 
door.

9.  When the wooden logs are burning well, the 

air control lever can be set to a position in 
the middle.

10. You can find out more about the correct volume of wood to add to the 

fire in the section “Volume of wood to add per hour” (see point 5.4.2).

11. When the wood has been completely burnt and only embers are remain-

ing from the initial wood added to the 
fire, new wood can now be added as 
required (hardwood is ideal).

12. Depending on the weather conditions, 

adjust the control lever towards the 
middle setting or a little over (Fig. 11). 
The correct setting is always based on 
experience and the current local conditions.

13. Always open the firebox door slowly. This will ensure that you avoid 

sudden low pressure in the firebox and prevent exhaust gases leaking 
into the living room.

14. This will prevent any possible smoke leakage through the opened door 

when adding new wood during the ember phase.

15. Never consistently add more wood than the recommended amount.

Caution:

 The height of the wood pile must not exceed the lower marking 

on the deflector plate!

Содержание L 800

Страница 1: ...GB Installation and Operating Instructions Linear Fireplace Cassettes...

Страница 2: ...otional level creating feelings of security and comfort To ensure this is achieved we recommend that you carefully read these operating instructions so that you can become quickly and comprehen sively...

Страница 3: ...needing protection 13 3 7 Expansion joint between the casing and the fireplace cassette 13 3 8 Combustion chamber design 13 3 9 Example installation 15 4 Installation 15 4 1 Installation of the firepl...

Страница 4: ...the outer casing of the fireplace cassette can become very hot Risk of burning Never allow these groups of people to touch or use a fireplace cassette without supervision when a fire is lit or has jus...

Страница 5: ...ncrete vermiculite Primary and secondary airflow systems Self closing firebox door with a high temperature resistant ceramic glass panel Heat resistant gloves Type plate mounting location see 5 2 1 2...

Страница 6: ...1 2 Exhaust gas systems residential chimneys Fireplaces may only be installed in rooms and locations where no danger results from their position structural conditions and type of use The sur face are...

Страница 7: ...oved for multiple installations 2 3 TECHNICAL DATA DIMENSION SHEETS The following information has been taken from the testing report and cor responds to the testing conditions Fireplace cassette XS 50...

Страница 8: ...H 130 150 150 150 150 I 352 412 442 472 502 J 100 convection air openings 125 Dimensions Linear cassettes Linear XS 500 mm Linear S 600 mm Linear M 700 mm Linear L 800 mm Linear XL 900 mm K 400 566 66...

Страница 9: ...Optional convection air sockets 100mm 1 Cassette frame 60 80 100 mm 2 Firebox door with ceramic glass 3 Firebox lining 4 Firebox 5 Inspection maintenance openings 6 Exhaust gas sockets rotatable vert...

Страница 10: ...the position of the operating handle 2 7 GENERAL REQUIREMENTS FOR THE USE OF FIREPLACE CASSETTES IN EXISTING FIREPLACES The fireplace cassettes are suitable amongst other things for retrofitting into...

Страница 11: ...ot be closed Ensure that there is sufficient combustion air minimum 360 m per hour and m of the firebox opening The fireplace cassette can be connected to a flexible exhaust gas flue which is fed thro...

Страница 12: ...nents The insulation thicknesses listed are based on the reference insulation material rock wool according to AGI Q 132 Silicon based insulation material can also be used with the relevant building ap...

Страница 13: ...s to be reduced significantly 3 7 EXPANSION JOINT BETWEEN THE CASING AND THE FIREPLACE CASSETTE There must be no direct connection between the fireplace cassette and the casing An expansion joint is t...

Страница 14: ...200 mm 60 mm XL 900 40 mm 60 mm 200 mm 60 mm Rock wool mats to AGI Q 132 Linear cassette Setup floor Mounting wall Ceiling Side wall XS 500 0 mm 50 mm 50 mm 60 mm S 600 0 mm 160 mm 120 mm 80 mm M 700...

Страница 15: ...o prevent fires and deflagration it is important to ensure that there are no dangerous deposits in the exhaust gas collection chamber These critical areas must be constructed in such a way that soot p...

Страница 16: ...additional thermal protection e g air deflector plate when they are within the thermal radiation field or are located in the area of the cassette s thermal air convection field This is particularly i...

Страница 17: ...sulated from the room s air 4 4 INSTALLING OR DISMANTLING THE FIREBOX INTO FROM THE CONVECTION AIR JACKET The firebox can be dismantled from the convection air jacket in its installed state Reasons fo...

Страница 18: ...blower then you only need to connect the plug to a properly earthed electricity socket The following steps should be carried out for maintenance inspection of the hot air blower 1 Dismantle the cover...

Страница 19: ...he control shaft is inserted through two holes in the frame when installing the frame It may be necessary to order a new cassette frame if the existing one does not have any corresponding holes 4 7 DI...

Страница 20: ...to the fixture move the door a little swivel the door 3 Loosen the hexagonal socket on the lower hinge with a 3 mm Allen key 4 Close the door and then push the safety clasp back onto the pin 4 8 INSTA...

Страница 21: ...ith cross slot Ensure that you initially screw the screws in loosely Tighten then only once all of the screws are screwed in 3 The exhaust gas connection is inserted into the exhaust gas socket This i...

Страница 22: ...L XL Linear XS 500 mm Linear S 600 mm Linear M 700 mm Linear L 800 mm Linear XL 900 mm 1 1 2 1032854 1017402 1017404 1017406 1017408 2 2 1017403 1017405 1017407 1017409 3 2 2 1032859 1017459 1017459...

Страница 23: ...e appliance must not be operated with the appliance door left open except as directed in the instructions The fireplace cassette may only be operated when the firebox door is closed The door must also...

Страница 24: ...a good level of room ventilation during this burning process Open all doors and windows to the outside Please note minor expansion or stress noises can occur during heating or cooling of the fireplac...

Страница 25: ...f required leave the fire box door open by approx 3 5 cm The fire should now light burning brightly and intensively 8 When the kindling wood is burning well add smaller hardwood logs or larger softwoo...

Страница 26: ...mod ern houses built after 1990 However the old information for room heating capacity can still be of interest as a comparative value or for use with older building structures that do not yet correspo...

Страница 27: ...transitional period meaning when the outside temperature is still high above approx 15 C or during unfavourable weather conditions katabatic winds etc it is possible to experience disruption to the ch...

Страница 28: ...clear as pos sible the less visible the exhaust gas appears the better the burning process Wood originating from Europool palettes Waste household rubbish or old clothing Paper paper briquettes carton...

Страница 29: ...leaned in a cold state Please note that cleaning can lead to soiling of the installation room and your clothing We recommend that you protect the area around the opening to the fire place from soiling...

Страница 30: ...be easily cleaned using standard fireplace glass cleaner which you can also obtain from your specialist dealer The glass fibre seals should not be soaked with cleaning fluids Finally wipe the glass p...

Страница 31: ...es on or may pass on to its customers in a particular case 8 2 GENERAL INFORMATION This quality manufactured product is state of the art The materials used were meticulously selected and are constantl...

Страница 32: ...hanged colour or other aspects due to ther mal stress Improper transport and or incorrect storage Improper handling of fragile components such as glass and ceramics Improper handling and or use Lack o...

Страница 33: ...rranty claims arising in a particular case 8 10 NOTE Your specialist dealer contractor will gladly advise and assist you in matters not covered by our warranty terms and conditions and undertakings We...

Страница 34: ...GB 34 NOTES...

Страница 35: ...GB GB GB 35...

Страница 36: ...ndial para su sal n Het merk van wereldformaat voor uw woonkamer wiatowa marka do Pa stwa salonu 1 D Ihr Fachh ndler UK Your specialist dealer F Votre revendeur sp cialis IT Il vostro rivenditore spec...

Отзывы: