7
Safety Instructions
ABOUT YOUR PRODUCT
The TrapJumper system was designed and manufactured as a pipeline inspection camera . All components are manufactured from high
grade materials . A system consists of a control box, color camera, and a push rod reel .
The TrapJumper is designed to survey pipes and sewers up to 40m in length . With a pressure-sealed camera allowing the camera to
be submerged up to 5m deep . The control box allows users to view and record the image, measure and document your findings to an
on-board storage device, overlay text via a keyboard and write a report onsite using the on-board reporting software . All data can be
exported via USB, SD card, wifi or ethernet interfaces .
WARNINGS, RISKS, SAFETY MEASURES, AND CARE
To reduce the risk of injury, all operators and maintenance personnel must read and understand the user manual before operating,
changing accessories, or performing maintenance on this camera equipment . Understanding these instructions will reduce the
risk of injury and damage to equipment and property . Care must be exercised by everyone using, maintaining, or working near this
equipment . They serve for your own safety as well as your coworkers .
BEFORE OPERATION
Risk of harm occurring must be considered before operating the equipment, as these can cause severe or fatal injuries . Please consider
the following:
CAUTION
1. Risk of Explosion!
Explosive atmospheres can be caused by flammable gases, mists or vapors, or by combustible dusts . If there is enough of the
substance, mixed with air, then all it needs is a source of ignition to cause an explosion .
Never
use a Spartan Tool inspection system
in pipelines that may contain these substances . In order to survey such conditions, contact Spartan Tool, LLC to obtain information
and equipment designed for such circumstances .
2. Environmental Risk!
Cross contamination and risk of infection: Contamination of drinking water sources by sewage can occur when waste water
inspection systems are used in fresh water pipelines . If sewage contaminates drinking water sources, harmful bacterial can cause
disease from the ingestion of micro-organisms such as E-Colia, Giardia, Cryptospordium, Hepatitis A, and Helminths .
Never
use an inspection system alternately between waste water and fresh water surveys . Cleaning your inspection system is
not
sufficient . Always use a separate unit dedicated for that particular environment .
Risk of infection and illnesses are not uncommon . Although mild cases of gastroenteritis and potentially fatal diseases, such as
leptospirosis (Weil's disease) and hepatitis do pose a serious risk .
To reduce the chances of contracting these diseases when surveying sewage pipelines ensure that employees and line
management understand the risks through proper instruction, training and supervision .
Provide suitable personal protective equipment, which may include waterproof/abrasion resistant gloves, footwear, eye and
respiratory protection . Face visors are particularly effective against splashes . Speaking to your doctor for preventative injections and
advice is recommended .