background image

STEP 7

STEP 8

STEP 9

Select a suitable tip and insert 

it completely into the barbed 

tip seat as shown. To deter-

mine the correct tip, refer to the 

tip chart.

Connect the product supply 

tube or product pickup tube.

Cut the tubing to the required 

length. Connect the foot valve 

/ filter to the hose. Slide the 

ceramic weight over the tube 

and as far as possible over the 

barbed fitting on the yellow foot 

valve.

STEP 10

STEP 11

Tip calibration

1.  Fill a graduated cylinder with 

the concentrated product.

2.  Using the chart in the manual, 

select and insert the tip closest 

to the desired dilution ratio.

3.  Insert the pickup hose into the 

graduated cylinder.

4.  Put the outlet tube into an open 

container and push the button 

or lever in order to activate the 

system. Draw up the product 

until the pickup tube is com-

pletely filled.

5.  Switch the system off and insert 

the delivery hose in a 1 gallon (or 5 liter) container.

6.  Mark the level of the product in the graduated container.

7.  Switch the system on again until the 1 gallon (or 5 liter) con-

tainer is completely full.

8.  Switch the system off and read the quantity of product in the 

graduated container.

9.  The difference in the product levels for points 6 and 8 indicates 

the amount of product mixed per gallon (or liter).

Use a cable tie to secure the 

tube on the barbed tip seat. 

For a 4-product selector, repeat 

the operations from step 7 to 

11 for each product.

 

Water

Water

+

Chemical

tank

Chemical

graduated

tank

PRODUCT PICKUP TUBE AND TIP INSTALLATION

CERAMIC 

WEIGHT

Содержание Clean on the Go

Страница 1: ...User Manual Clean on the Go Dispenser...

Страница 2: ...mplete installation kit Plastic clamps 2 pcs for each product Metering tips 1 bag for each product Foot filter and non return valve assembly 1 piece for each product Ceramic weight 1 piece for each pr...

Страница 3: ...scharge hose only into a specific container not toward yourself or another person Calibrate the dosing as per the product label instructions This unit is supplied with an internal back flow prevention...

Страница 4: ...and secure the bracket with the three supplied screws Attach the system to the mount ing bracket and slide it down until the top tab clicks in place securing the system to the mounting bracket STEP 4...

Страница 5: ...the left side of the first system by pulling the rear clip to its outward most position as shown and remove the end cap Unlock the right side of the second system by pulling the clip to its outward mo...

Страница 6: ...the outlet tube into an open container and push the button or lever in order to activate the system Draw up the product until the pickup tube is com pletely filled 5 Switch the system off and insert t...

Страница 7: ...0 Low Flow Mint Green tip 0 41mm 2 99115 Low Flow Aqua tip 0 46mm 2 99112 High Flow Orange tip 0 63mm 2 99109 High Flow Brown tip 0 58mm 2 99110 High Flow Yellow tip 0 51mm 2 99111 High Flow Purple ti...

Страница 8: ...r A gap is spraying out and or leaking 1 Limescale film or dirt on the A gap s upper nozzle 1 Soak in hot water and limescale remover to remove buildup Replace if necessary 2 Venturi coated with limes...

Отзывы: