TC-610H PLUS Manual

Each SPARMAX compressor is tested and fully inspected to ensure its quality and performance at the time of factory dispatch. Warranted for 

TWO

 years from date 

of factory dispatch against workmanship or material defect resulting in inoperable compressor. Exclude parts subject to wear: auto stop pressure switch, piston 

set, etc. and damage or loss caused by improper use, unauthorized alteration and negligence.

1. Insert the 2 detachable Airbrush Holders onto the 2 rubber grommets on top of metal case.

2. Plug the compressor into a wall socket that supplies matching voltage and frequency to those indicated on the voltage label of the unit.

3. Flip the On/Off Switch to I (On) to turn on the compressor. The compressor will continue to run until the Air Tank reaches the Auto OFF setting of 60 PSI.

4. Pull up the Pressure Regulator Knob and turn clockwise until you hear a click, which indicates the pressure is turned up to its maximum.

5. Press the airbrush trigger and check the Pressure Gauge reading. This is the maximum allowable working pressure of this specific airbrush-compressor  

    combination.

6. To adjust working pressure, pull up the Pressure Regulator Knob, and with the airbrush trigger still depressed: turn the Knob counter-clockwise to decrease,  

    clockwise to increase. Push down the Knob to lock into the pressure setting. 

7. Once the Air Tank pressure drops to the Auto ON setting of 40 PSI during airbrushing, the compressor will automatically start again until it reaches the auto  

    OFF setting of 60 PSI.

8. Between breaks, airbrushes can be placed onto the airbrush holders.

9. Continuous operation of the compressor is suggested for no more than 1 hour with the Auto Stop Pressure Switch in action. Turn off the compressor by  

    flipping the On/Off Switch to 0 (OFF), and allow it to cool for 10~15 minutes before turning it back on.

    CAUTION: If the Auto Stop function does not activate, and the compressor is running non-stop, limit continuous use to 40 minutes, and do not allow  

    the compressor to run above 80 psi.

10. For safety purpose, the compressor is equipped with a thermal switch. If the temperature rise reaches the thermal limit, the compressor will shut down  

    automatically. Turn off the compressor and allow it to cool for 10~15 minutes before turning it back on.

11. At the end of each session, turn off, unplug the compressor, and follow the 

MAINTENANCE 

instructions.

www.SPARMAXair.com

OPERATION

1. Push up the Filter Drain Valve to release built up moisture and condensed water.

2. Release remaining pressure by pressing the airbrush trigger.

3. Holding a container below the Air Tank Drain Valve, open the Drain Valve, tip the compressor back and forth gently to drain, then close the Drain Valve.

NOTE: Due to structural limit of the Air Tank and Drain Valve, some moisture and water would always remain within the Air Tank despite proper  

drainage after each use, and the natural corrosion process will take place continuously, resulting in yellowish drained water even after the first use.  

This is normal and does not affect the performance or safety of the Air Tank.

MAINTENANCE

Auto Stop Turns the Compressor On and Off Without Airbrush Trigger Depressed   

1. Apply soap water at connections, tighten connections with bubbling which indicates air leak.

2. Inspect the hose for damage or try using another hose.

Other Issues

For all other issues including, but not limited to the below, please turn off the compressor, contact the original seller with a description of the issue encountered, 

serial number on the voltage label, working conditions, i.e. frequency and duration of each continuous use, purchase date, and how long was the unit used since 

initial purchase.

1. No pressure.

2. Low pressure.

3. Auto Stop does not activate.

4. Motor doesn’t run, note whether there is humming sound.