Spark RETRO 2 Скачать руководство пользователя страница 2

2

SAFETY 
INFORMATION 

WARNINGS

Carbon  Monoxide  Poisoning: 

Early  signs  of  carbon  monoxide 
poisoning  resemble  the  flu,  with 
headaches, dizziness, or nausea. If 
you  have  these  signs,  the  fire 
Ribbon  may  not  be  working 
properly. 

Get  fresh  air  at  once! 

Have  Fire  Ribbon  serviced.  Some 
people  are  more  affected  by 
carbon  monoxide  than  others. 
These  include  pregnant  women, 
people  with  heart  or  lung  disease 
or  anemia,  those  under  the 
influence  of  alcohol,  and  those  at 
high altitudes. 

Natural  and  Propane  /LP  Gas: 

Natural and propane /LP gases are 
odorless. An odor making agent is 
added  to  the  gas.  The  odor  helps 
you  detect  a  gas  leak.  However, 
the odor added to the gas can fade. 
Gas  may  be  present  even  though 
no odor exists. 

Make certain you read and under-
stand  all  warnings.  Keep  this 
manual  for  reference.  It  is  your 
guide to safe and proper operation 
of this Fire Ribbon. 

1. This appliance, as supplied, is

only  for  use  with  the  type  of
gas  indicated  on  the  rating
plate.

2. If you smell gas:

shut off gas supply

do  not  try  to  light  any  appli-
ance

do  not  touch  any  electrical
switch;  do  not  use  any  phone
in your building

immediately  call  to  your  gas
supplier  from  a  neighbor’s
phone. 

Follow 

the 

gas

supplier’s instructions

if  you  cannot  reach  your  gas
supplier,  call  the  fire  depart-
ment

3. Never install the Fire Ribbon:

in a recreational vehicle

where 

curtains, 

furniture,

clothing,  or  other  flammable
objects are less than 42 inches
from the front, top, or sides of
the Fire Ribbon

in the high traffic areas

in windy or drafty areas

4. Before  installing  in  a  solid

fuel  burning  fireplace,  the
chimney  flue  and  firebox
must  be  cleaned  of  soot,
creosote,  ashes  and  loose
paint  by  a  qualified  chimney
cleaner. Creosote will ignite if
highly  heated.  Inspect  chim-
ney flue for damage.

5. Fire  Ribbon  is  designed  to  be

smokeless.  If  it  ever  appears

to  smoke,  turn  off  appliance 
and  call  a  qualified  service 
person. 

NOTE:

 During initial 

operation, 

slight 

smoking 

could occur due to unit curing 
and 

the 

burning 

of 

manufacturing residues.  

6. To reduce the creation of soot,

follow  the  instructions  in

Cleaning  and  Maintenance

,

page 9.

7. Do  not  allow  fans  to  blow

directly  into  the  fireplace.
Avoid  any  drafts  that  alter
burner  flame  patterns,  as  it
could increase soothing.

8. Do  not  use  a  blower  insert,

heat exchanger insert or  other
accessory  not  approved  for
use with this Fire Ribbon.

9. This  Fire  Ribbon  needs fresh,

outside  air  ventilation  to  run
properly.

10. Keep  the  appliance  area  clear

and  free  from  combustible
materials,  gasoline  and  other
flammable vapors and liquids.

11. Do  not  burn  solid  fuel  in  the

fireplace  after  installing  the
Fire  Ribbon.  Do  not  use  this
appliance  to  cook  food  or
burn paper or other objects.

12. Fire  Ribbon  becomes  hot

when  in  use.  Keep  children
and  adults  away  from  hot
surface  to  avoid  burns  or
clothing  ignition.  Fire  Ribbon
will  remain  hot  for  a  time
after

shut-down. 

Allow 

surface 

to 

cool

before 

touching.

13. Carefully  supervise  young

children  when  they  are  in  the
room with Fire Ribbon.

14. Do  not  use  appliance  if  any

part  has  been  exposed  to  or
under water. Immediately call
a  qualified  service  technician
to  inspect  the  room  appliance
and  to  replace  any  part  of the

WARNING:

  Any  change 

to  this  Fire  Ribbon  or  its 
controls can be dangerous.

WARNING:  Keep  flue 

open when operating unit.

IMPORTANT: 

Read 

this 

owner’s  manual  carefully 
and completely before trying 
to  assemble,  operate,  or 
service  this  Fire  Ribbon. 
Improper use of this unit can 
cause 

serious  injury  or 

death 

from 

burns, 

fire, 

explosion,  electrical  shock, 
and 

carbon 

monoxide 

poisoning. 

DANGER:  Carbon  mo-

noxide  poisoning  may  lead 
to death!

 

Содержание RETRO 2

Страница 1: ...s of life WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For as...

Страница 2: ...ill ignite if highly heated Inspect chim ney flue for damage 5 Fire Ribbon is designed to be smokeless If it ever appears to smoke turn off appliance and call a qualified service person NOTE During in...

Страница 3: ...ment in full and proceed to the step 5 NOTE If you are planning to add some topping media optional colored glass or lava rock leave approximately not filled on top of burner media and proceed to the n...

Страница 4: ...e Ribbon INSTALLING DAMPER CLAMP Secure the damper stop clamp provided to the leading edge of the damper as shown below If for any reason this clamp doesn t work on your fireplace another suitable cla...

Страница 5: ...regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 13 inches of water If you do not reduce incoming gas pressure burner system regulator damage could...

Страница 6: ...raps moisture and contaminants This keeps them from going into the burner system gas controls If sediment trap drip leg is not installed or is installed wrong burner system may not run properly Figure...

Страница 7: ...102 000 142 000 128 000 110 000 146 500 41 000 33 500 4 1 8 2 5 2 6 2 7 2 2 1 3 1 43 38 43 38 43 43 43 41 43 46 44 49 44 43 MODEL RETRO 2 NG LP RETRO 3 NG LP RETRO 4 NG LP RETRO 5 NG LP RETRO 6 NG LP...

Страница 8: ...ion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any ga...

Страница 9: ...WA If using a soap and water solution to test for leaks DO NOT spray solution onto control body WARNING Never use an open flame to check for gas leak DANGER 1 STOP Read the safety information on previ...

Страница 10: ...lower cover Depress and turn knob clockwise to OFF position TO TURN OFF GAS TO APPLIANCE Off Position Pilot Position 2 Replace lower cover The ON REMOTE OFF switch for the main burner can be found on...

Страница 11: ...ormal operation The pilot flame must always be present when the fireplace is in operation The pilot flame has two distinct flames one engulfing the thermopile and the other reaching to the main burner...

Страница 12: ...where flames contact the media This is especially true with propane LP gas Burner is excessively noisy Note The movement and combustion of gas will create low unavoidable levels of noise Burner flame...

Страница 13: ...pile which allows thermopile to cool causing pilot flame to go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged pilot 5 Thermopile conn...

Страница 14: ...g statement at top of page OBSERVED PROBLEM Fire Ribbon produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 Open flue to maximum Stop using o...

Страница 15: ...ILLUSTRATED PARTS LIST SEE NEXT PAGE 1 2 3 4 5 8 9 10 11 FOR PART DESCRIPTION 13 12 6 7...

Страница 16: ...20 R100020 R100020 R100020 1 R200020 R200020 R200020 R200020 R200020 R200020 R200020 3 Valve Bracket R100021 R100021 R100021 R100021 R100021 R100021 R100021 1 4 Pilot Assembly R100022 R100022 R100022...

Страница 17: ...Fire Ribbon Model for Natural Gas and LP Key Part Description RETRO 2 RETRO 3 RETRO 4 RETRO 5 RETRO 6 RETRO 7 RETRO 8 Q ty 8 Orifice Air Mixer R100044 2 R200061 1 R100044 3 R200062 1 R100043 4 R20006...

Страница 18: ...1 R200032 R200033 R200034 R200035 R200036 R200037 R200038 10 Front Cover R100102 R100103 R100104 R100105 R100106 R100107 R100108 1 11 12 Access Panel Remote Control Receiver D400058P 1 1 D400058P D40...

Страница 19: ...bows Quantity 45 Elbows ALTITUDE Feet Above Sea Level Was Stove Derated Yes No If Yes To What Orifice Size Unusual Structure Near Vent Inside Corner Trees Shrubs Other Termination Please Describe Prev...

Страница 20: ...ppliance and does not extend to 1 firebox burner assembly damaged by accident neglet misuse abuse alterations negligence of others inclu ding the installation thereof by unqualified installers 2 the c...

Отзывы: