background image

321-L-06-5

      

APPROVED 

Z21.60b-2004 / 

CSA 2.26b-2004

SPARK MODERN FIRES 

RETROFIT FIRE RIBBON  

VENTED DECORATIVE APPLIANCE 

 

O W N E R ’ S  O P ER A T I O N  AN D  I N ST A L L A T I O N  M AN U AL 

-  Installation  and  service  must  be  performed 

by  a  qualified  installer,  service  agency,  or 

the gas supplier. 

-

  Do  not  store  or  use  gasoline  or  other 

flammable vapors and liquids in the vicinity 

of this or any other appliance. 

-

  WHAT TO DO IF YOU SMELL GAS: 

Do not try to light any appliance. 

Do not touch any electrical switch; do not 

use any phone in your building. 

Immediately call your gas supplier from a 

neighbor’s 

phone. 

Follow 

the 

gas 

supplier’s instructions. 

If you cannot reach your gas supplier, call 

the fire department. 

WARNING:  If  the  information  in  this 
manual  is  not  followed  exactly,  a  fire 
or  explosion  may  result  causing 
property  damage,  personal  injury,  or 
loss of life. 

WARNING: 

Improper 

installation, 

adjustment, 

alteration, service, or maintenance can cause injury 

or property  damage.  Refer  to  this  manual  for 

correct installation and operational procedures. For 

assistance  or  additional  information  consult  a 

qualified installer, service agency, or gas supplier. 

WARNING: This appliance is for installation only in 

a solid-fuel burning masonry or UL127 factory-built 

fireplace,  constructed  of  noncombustible  material, 

and  connected  to  a  working  flue 

(see  page  4 for 

minimum flue opening)

WARNING: This is a gas-fired appliance. It uses air 

(oxygen)  from  the  room  in  which  it  is  installed. 

Provisions  for  adequate  combustion  and  ventila-

tion air must be provided.  

INSTALLER: Leave this manual with the appliance. 

CONSUMER:Retain this manual for future reference

NOTE: This appliance is not approved for installation in bedrooms or bathrooms.

Version française de ce manuel est disponible à partir du site WEB : www.sparkfires.com

French version of this Owners Manual is available at www.sparkfires.com

Содержание RETRO 2

Страница 1: ...s of life WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For as...

Страница 2: ...ill ignite if highly heated Inspect chim ney flue for damage 5 Fire Ribbon is designed to be smokeless If it ever appears to smoke turn off appliance and call a qualified service person NOTE During in...

Страница 3: ...ment in full and proceed to the step 5 NOTE If you are planning to add some topping media optional colored glass or lava rock leave approximately not filled on top of burner media and proceed to the n...

Страница 4: ...e Ribbon INSTALLING DAMPER CLAMP Secure the damper stop clamp provided to the leading edge of the damper as shown below If for any reason this clamp doesn t work on your fireplace another suitable cla...

Страница 5: ...regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 13 inches of water If you do not reduce incoming gas pressure burner system regulator damage could...

Страница 6: ...raps moisture and contaminants This keeps them from going into the burner system gas controls If sediment trap drip leg is not installed or is installed wrong burner system may not run properly Figure...

Страница 7: ...102 000 142 000 128 000 110 000 146 500 41 000 33 500 4 1 8 2 5 2 6 2 7 2 2 1 3 1 43 38 43 38 43 43 43 41 43 46 44 49 44 43 MODEL RETRO 2 NG LP RETRO 3 NG LP RETRO 4 NG LP RETRO 5 NG LP RETRO 6 NG LP...

Страница 8: ...ion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any ga...

Страница 9: ...WA If using a soap and water solution to test for leaks DO NOT spray solution onto control body WARNING Never use an open flame to check for gas leak DANGER 1 STOP Read the safety information on previ...

Страница 10: ...lower cover Depress and turn knob clockwise to OFF position TO TURN OFF GAS TO APPLIANCE Off Position Pilot Position 2 Replace lower cover The ON REMOTE OFF switch for the main burner can be found on...

Страница 11: ...ormal operation The pilot flame must always be present when the fireplace is in operation The pilot flame has two distinct flames one engulfing the thermopile and the other reaching to the main burner...

Страница 12: ...where flames contact the media This is especially true with propane LP gas Burner is excessively noisy Note The movement and combustion of gas will create low unavoidable levels of noise Burner flame...

Страница 13: ...pile which allows thermopile to cool causing pilot flame to go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged pilot 5 Thermopile conn...

Страница 14: ...g statement at top of page OBSERVED PROBLEM Fire Ribbon produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 Open flue to maximum Stop using o...

Страница 15: ...ILLUSTRATED PARTS LIST SEE NEXT PAGE 1 2 3 4 5 8 9 10 11 FOR PART DESCRIPTION 13 12 6 7...

Страница 16: ...20 R100020 R100020 R100020 1 R200020 R200020 R200020 R200020 R200020 R200020 R200020 3 Valve Bracket R100021 R100021 R100021 R100021 R100021 R100021 R100021 1 4 Pilot Assembly R100022 R100022 R100022...

Страница 17: ...Fire Ribbon Model for Natural Gas and LP Key Part Description RETRO 2 RETRO 3 RETRO 4 RETRO 5 RETRO 6 RETRO 7 RETRO 8 Q ty 8 Orifice Air Mixer R100044 2 R200061 1 R100044 3 R200062 1 R100043 4 R20006...

Страница 18: ...1 R200032 R200033 R200034 R200035 R200036 R200037 R200038 10 Front Cover R100102 R100103 R100104 R100105 R100106 R100107 R100108 1 11 12 Access Panel Remote Control Receiver D400058P 1 1 D400058P D40...

Страница 19: ...bows Quantity 45 Elbows ALTITUDE Feet Above Sea Level Was Stove Derated Yes No If Yes To What Orifice Size Unusual Structure Near Vent Inside Corner Trees Shrubs Other Termination Please Describe Prev...

Страница 20: ...ppliance and does not extend to 1 firebox burner assembly damaged by accident neglet misuse abuse alterations negligence of others inclu ding the installation thereof by unqualified installers 2 the c...

Отзывы: