ADJUST SET TEMPERATURE POINT
The SpaNET intelligent software constantly monitors
the spa water, automatically controlling the heater
and circulation pump to ensure the desired set water
temperature is maintained. The user can adjust the
o
o
set temperature point from 5 C - 41 C in steps of
o
o
0.2 C increments (Default: 38 C).
To adjust the set temperature point:
1)
Press and hold
the
UP
( ) or
DOWN
( )
button. The set temperature point will begin
o
adjusting up or down in 0.2 C increments.
2) Once the desired set temperature is displayed
press the
OK
( ) button to confirm selection.
Notes: 1) If the optional in-pool temperature sensor is fitted
o
the heater works off a 0.5 C hysteresis (thermostat). The
heater will raise the water to the set temperature point but
thereafter will not be re-activated until the water
o
temperature falls by at least 0.5 C. Therefore if the spa
o
user selects a set temperature point of 38 C the actual
o
o
water temperature will be anywhere between 37.5 C - 38 C
depending on when the user checks the temperature.
2) If the standard in-heater temperature sensor is used (i.e.
no optional in-pool temperature sensor fitted) the heater
o
works off a 2 C hysteresis (thermostat). The heater will
raise the water to the set temperature point but thereafter
will not be re-activated until the water temperature falls by
o
at least 2 C.Therefore if the spa user selects a set
o
temperature point of 38 C the actual water temperature will
o
o
be anywhere between 36 C - 38 C depending on when the
user checks the temperature.
COUNTDOWN TIMER
The XS-3000 features an integrated countdown
timer that enables the user to set an audible alarm to
sound after a user determined period (5-60 minutes).
The timer will count down the selected period and
show minutes and seconds remaining on the LCD as
it does. The timer icon ( ) will be displayed in the
top right of the LCD screen whilst the timer is
running. Once the countdown time has elapsed the
topside panel will beep for one minute or until a
button is pressed.
NOTE: The pump(s), blower and light
time-out periods are NOT adjusted by the minute timer.
To start the countdown timer:
1) Press the
UP
( ) or
DOWN
( ) button to
toggle the screen to the
TIMR
( ) display mode.
2) Press
OK
( ) to select desired time period.
3) Press the
UP
( ) or
DOWN
( ) button to
adjust the timer in minute increments until the
desired time period is selected.
4) Press
OK
( ) to confirm and begin countdown
.
CLOCK
For convenient user reference and to assist in
filtration & sleep time functions, your spa controller
includes a built-in real time clock. The user can
choose to display the time in either 12 or 24 hour
format. For ease of reference the current time and
day is displayed at the bottom left of the LCD
screen.
To set the clock:
1) Press the
UP
( ) or
DOWN
( ) button to
toggle the screen to the
TIME
( ) display
mode.
2) Press the
OK
( ) button to enter set time
adjustment.
3) Press the
UP
( ) or
DOWN
( ) button to
select the time format (12 or 24 HR). Press
the
OK
( ) button to confirm selection.
4) Press the
UP
( ) or
DOWN
( ) button to
modify the weekday (Mon - Sun). Press the
OK
( ) button to confirm selection.
5) Press the
UP
( ) or
DOWN
( ) button to
modify the hour. Press the
OK
( ) button to
confirm selection.
6) Press the
UP
( ) or
DOWN
( ) button to
modify the minutes. Press the
OK
( ) button
to confirm selection.
XS-3000 Quick Reference Guide
OK
Buttons:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Indicator Lights
13.
Auto Mode LED
14.
Element On LED
15.
Ozone/UV On LED
16.
Sleep Cycle LED
UP
Light
(On /Off)
OK
Light Mode
Light (Speed / Colour)
DOWN
o
Invert Display
180
Pump A
Pump B
Pump C
Air Blower
One-Touch Sanitise
DISPLAY MODES
The XS-3000 topside panel features a large LCD
screen which displays three items: (1) Actual Water
Temperature (2) Set Temperature Point (3) Time &
Day. By default the actual water temperature is
displayed in the large digits (refer below).
There are four possible items that can be displayed
in the large digits: (1) Actual Water Temperature
[W.TMP]*; (2) Set Temperature [S.TMP];
(3) Countdown Timer [TIMR]; (4) Time Clock [TIME].
Each display mode has a unique icon shown at the
top of the screen to indicate the current item being
viewed (refer below).
Press the
UP
( ) or
DOWN
( ) button to scroll
through these different display modes. As you scroll
through each item a brief title screen will be shown
followed by the actual display mode (note change in
icon).
Note: There is a ten (10) second timeout on viewing non
default display modes. If no button press is sensed after 10
seconds the screen will return to the default display.
LED INDICATOR LIGHTS
The AUTO LED indicator turns ON when
the filtration pump is in automatic mode.
The Heater LED indicator turns ON when
the heater element is active.
The Ozone LED indicator turns ON when
the ozonator / UV sanitiser is active.
The Sleep Cycle LED indicator turns ON when
in a designated sleep cycle (if programmed).
AUTO
3
O
zZz
SA SU
TU WE TH FR
MO
SET TEMP
SET TEMP
°C
°F
°C
°F
°C
°F
MODE
SPD
BRT
MODE
SPD
BRT
OFF
ON
AM
PM
AM
PM
:
10 30
3 8.0
Actual
Water Temp
W.TMP Display Mode Icon
Time & Day
Set Temp Point
W.TMP Water Temperature*
S.TMP Set Temperature
TIMR
Countdown Timer
TIME
Clock
* Default Display
OK
OK
OK
OK
OK
OK
OK
Safety Notes:
The appliance must be connected to a suitably rated and
weather protected power supply. The supply line should be a
dedicated power circuit and means for disconnection must
be incorporated in the fixed wiring in accordance with your
local wiring regulations.
Means for disconnection from the
supply mains should have a contact separation in all poles
that provide full disconnection under overvoltage category III
conditions.
The appliance must be supplied through a
residual current device (RCD) having a rated residual
operating current not exceeding 30mA.
This appliance is
not intended for use by young children or infirm persons
without supervision.
SV-3T
13
14
15
16
1
3
4
9
8
5
6
7
10
11
12
2