SPAN F500S Скачать руководство пользователя страница 26

25

WARRANTY POLICY

Span-America (“Span”) offers a limited warranty on all patient lifts, slings and accessories to be free of defects in workmanship 
and product performance. This warranty extends only to the original purchaser and is non-transferrable. All warranty claims must 
be submitted by the authorized dealer or distributor who originally sold the product with proper proof of sale and serial number 
where applicable. Prior Return Authorization (RA) from Span is required for all warranty replacements. Span reserves the right to 
repair or replace only defective parts or accessories in lieu of a complete new patient lift. The repaired or replacement part shall 
be warranted for a period equal to the remainder of the warranty period of the defective part.

Span does not provide advance replacements for warranty claims.  For situations where an end user requires a replacement in 

advance and before a warranty item can be returned, dealer or distributor must purchase the replacement at full cost.  All freight 
charges for the replacement are the sole responsibility of the dealer or distributor. When end user returns warranty item and item 
proves to be defective, Span will issue full credit for the replacement less freight charges.

Product returned without RA number clearly marked on the package or product returned later than 30 days after authorization 

will be refused and returned at sender’s expense. Final disposition of warranty claims will be determined at the sole discretion 

of Span.  Warranty claims will be denied for any of the following: product abuse or misuse, accidental or malicious damage, 

improper installation, product used with parts, components or accessories with quality or specifications incompatible with product, 

adulterated product, user neglect, failure to maintain and service product as specified in the owner’s manual or care tag, serial 

number removed or defaced, or normal wear and tear. 

Span warrants the following products and components beginning from the purchase invoice date for the specified time period:

WARRANTY PERIOD

PRODUCT OR COMPONENT

Three (3) Years

Patient lift frame or spreader bar

Two (2) Years

Actuator, control box, pendant, charger, weigh scale, Stand Aids, or casters excluding normal tread wear

One (1) Year

Battery or hydraulic pump

Six (6) Months

Reusable fabric slings

Single Patient Specific slings are designed for limited use with one patient and may not be laundered. Span will replace any 

disposable sling found to have a manufacturing defect. Normal wear and tear will not be covered under warranty.

This warranty expressly excludes wearable components including but not limited to foam parts and caster tread.  Furthermore, 

this warranty is void and null for product that has not been purchased or paid for in full.

RETURN GOODS POLICY

Patient lifts may not be returned unless the wrong lift is shipped in error by Span or the lift is heavily damaged or defective out of 

the box.  For all other items, purchaser may request a RA for purchased goods within thirty (30) days of purchase invoice date.  

All returns must be received by Span no later than thirty (30) days after authorization or the RA will be voided. Return package 
must be clearly marked with the RA number or the package may be refused and returned at sender’s expense. Patient lifts are 
subject to a minimum restocking fee of 25% or more.  Please note that patient lifts being returned must be in the original carton 

with all parts, components and packing materials included. Failure to comply with this requirement will incur higher restocking 

fees or a rejection of the return. Slings, parts and accessories may only be returned if they have not been used. There are no 
exceptions to this provision.

All freight charges are the sole responsibility of purchaser when any of the following occurs:  (i) ordering error where an incorrect 
item is shipped in accordance with purchase order, (ii) an order is cancelled while in transit or (iii) delivery is refused by customer. 

Span reserves the right to issue credit amounts based on strict adherence to this policy.

Contact your dealer immediately if standard troubleshooting techniques do not 

correct the failure. Do not attempt to lift until all failure and safety issues have 

been resolved.

The Emergency Lowering Device is located at the top of the actuator shaft. It is 

Содержание F500S

Страница 1: ...0S SIT TO STAND PATIENT LIFT Ensure the product has been assembled according to the instructions in this manual All operators should read and understand the instructions for safe and proper operation of the patient lift P11584 ...

Страница 2: ...FINITIONS SYMBOLS In this manual the user refers to the patient or resident and may be used interchangeably at different times Caregiver refers to the operator or person who is assisting with the transfer Warning Failure to heed this warning may result in damage to the product or serious injury to the operator and or user Important instructions follow Read and understand the instructions in the ma...

Страница 3: ... etc to another The patient lift should not be used for transporting or moving any patient from one location to another location During lifting or lowering whenever possible always keep the base of the lift in the widest position The base of the lift should be closed before moving the lift Do not roll casters over any object while the user patient is in the sling Do not lock casters during lifting...

Страница 4: ... NOT consist of any materials or ingredients to which patients are exposed that may cause bodily harm or injury Prolonged exposure or physical contact with any part of the equipment will not cause skin irritation allergic reaction etc Using accessories detachable parts or materials not described in the instruction manual MAY RESULT IN SERIOUS INJURIES Keep the equipment away from children and pets...

Страница 5: ... lb 0 3 kg 9 Mast 14 3 lb 6 5 kg Emergency Stop Button 5 Leg Opening Lever 1 1 lb 0 5 kg 10 Actuator 7 3 lb 3 3 kg Heaviest detachable part UNLESS OTHERWISE SPECIFIED SHEET SCALE PART NUMBER DESCRIPTION DATE DRAWN BY MATERIAL FINISH 2920 PACIFIC DRIVE NORCROSS GA 30071 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BESTCARE LLC ANY REPRODUCTION IN PA...

Страница 6: ... E D F 700 H I G M N L K J A 1500 5 59 1 B 559 7 22 0 C 940 7 37 0 D 19 8 0 8 E 386 8 15 2 F 816 1 32 1 G 749 8 29 5 H 547 21 5 I 291 9 11 5 J 646 3 25 4 K 200 8 7 9 L 201 2 7 9 M 123 4 4 9 N 33 4 1 3 mm in F500S ...

Страница 7: ...ter with Brake 3 3 Dual Front Caster 4 Power Control Unit 5 Single Piece Molded Kneepad 6 Depth Adjustable Kneepad Position Optional Features 1 Charging Cradle 2 Second Battery Pack F500S Lift Weight Unloaded lb 107 1 Lift Weight Unloaded kg 48 7 SPECIFICATIONS OPTIONS Specifications of Control Unit Input Voltage 220 240VAC 50Hz 110 120VAC 60Hz Output Voltage 24 VDC Battery Pack 24 VDC 5AH Lift Con...

Страница 8: ...7 F500S TA24 Actuator TC12 Control Box ...

Страница 9: ...8 Step 2 Boom Installation Step 1 Base and Mast 1 3 2 ...

Страница 10: ...9 Step 4 Actuator 2 1 Step 3 Footplate ...

Страница 11: ...10 Step 5 Knee Pad 1 2 3 4 ...

Страница 12: ...DRAWN BY MATERIAL FINISH 2920 PACIFIC DRIVE NORCROSS GA 30071 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BESTCARE LLC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN 9 27 2017 M4x0 7x10mm Machine Screw ALL DIMENSIONS IN MM 1 6 6 30 30 120 120 400 0 1 0 2 0 3 0 5 1 ...

Страница 13: ...itional Battery Pack Optional Power Control Unit Overview 1 Connect Actuator as shown above 2 Connect Hand Control as shown above WARNING Contains a long charger cord that may cause strangulation if used improperly Keep long charger cord out of walkway where it poses a tripping hazard Have the charger port on the controller facing away from the wall for easy disconnection ...

Страница 14: ... be one that serves the needs of the patient while providing the patient with optimal safety Never interfere with the lift unless instructed by the attendant Have a doctor nurse or medical attendant experienced in the use of the device present during the first few times the lift is used to transfer a new user i i For optimum performance the lift should be transported and stored in following condit...

Страница 15: ...r signs below The DC Charger must be connected The emergency stop button must be released The battery will not be charged if the emergency button is pressed in LCD Display Panel Signs When the emergency stop button is released the LCD Display Panel will show one of the four signs below The sign will display for 5 seconds Then the lift will go into standby mode and the sign disappears The lift is r...

Страница 16: ...15 LED Indicator Green In Use Blank Standby Lifting Lowering Operating Lift Using Hand Control Operating Lift Using LCD Display Panel ...

Страница 17: ...w the LCD Display Panel will show the sign on the left either when the emergency stop button is released or when a button on the LCD Display Panel is pressed Lift operation is deactivated Battery needs to be charged immediately be fore further use Warning Battery Low and Charging is Needed If the battery needs to be charged the LCD Display Panel will show a blinking low battery sign shown on the l...

Страница 18: ...del Sling Description WP SA400E KB Knee Belt Stand Assist Buttock Strap Stand Assist Sling Available slings compatible with Stand Assist Lift If the patient is pregnant or has skin conditions con sult with doctor before use ALWAYS check the sling weight capacity is suitable for the patient All slings are type BF applied parts ...

Страница 19: ...are firmly on the platform and knees are touching the kneepads with kneecaps just above the padding Use the lift to complete the lift and pivot transfer Position the patient in a sitting position Slide the sling down patient s back to lumbar position Draw the shoulder staps to the front of the patient close to the chest Draw the waist belt around patient s waist and press together to fasten P 3 Fo...

Страница 20: ...f the patient when being lifted Fit the Stand Assist sling following Fitting Stand Assist Sling instructions the Buttock strap can be used only IN CONJUNCTION WITH the Stand Assist sling never by itself These slings are designed to compliment one another in providing the greatest comfort and security for the patient being transferred a b FITTING STAND ASSIST BUTTOCK STRAP FITTING KNEE BELT Pull op...

Страница 21: ...the knee pad Attached the sling straps to the hooks Have the patient s hands holding the handles For patients who cannot hold the handles have them hold their arms around the chest Press the UP button on the hand control Before the patient s body has lifted from the bed stop and make sure the sling is secured and patient s knees are against the knee pad The patient should be comfortable with the p...

Страница 22: ... 20 000 cycles The expected lifetime of the electrical components are 3 years Contact Span America for recycling information First Received Monthly Every 3 Months Check connections between boom and spreader bar for improper connection Check connections between boom and mast for improper connection looseness or wear Check the boom for bending and deflection Check the mast for bending or deflection ...

Страница 23: ... purpose Cleaning and Disinfecting Cleaning of the lift Cleaning of the sling Solvents or strong liquids or abrasive cleaning products will damage the surfaces of the lift Use pH neutral detergents only Remove the battery from the controller Clean lift surfaces control box and hand control with a damp cloth using pH neutral detergent Remove debris and hair from the casters and make sure the caster...

Страница 24: ...ng on usage The actuator will either go up or down but not both Replace your hand control as it is at the end of its life cycle Your control box may be malfunctioning There is a grinding sound inside the actuator when lifting Replace your actuator as the internal gears are stripped The actuator stops and starts while lifting or lowering Replace the batteries or battery pack as they are at the end ...

Страница 25: ...cy Lowering Device is located at the top of the actuator shaft It is intended for use if the actuator or electronics fail to operate while the patient is suspended in midair The device consisting of a plastic collar ring that should be first pulled down and turned clock wise continually until the patient has been lowered NOTE THE EMERGENCY LOWERING DEVICE IS INTENDED FOR USE DURING LIFT FAILURE TH...

Страница 26: ...ants the following products and components beginning from the purchase invoice date for the specified time period WARRANTY PERIOD PRODUCT OR COMPONENT Three 3 Years Patient lift frame or spreader bar Two 2 Years Actuator control box pendant charger weigh scale Stand Aids or casters excluding normal tread wear One 1 Year Battery or hydraulic pump Six 6 Months Reusable fabric slings Single Patient S...

Отзывы: