TECHNICAL SUPPORT - tel. +48 71 31 59 068

IN CASE OF ALARM

Turn off the gas supply, shut off the stove. Open the doors and windows. 
Before you leave, check if anyone has left in the room. Then leave the 
room and do not return. Call the rescue service for help (gas service, fire 
brigade, etc.).

INSTALLATION

SC\1B sensor is intended for use in the rooms where the potential risk 
resulting from the dangerous concentration of carbon monoxide is the 
highest. The device is ideal for kitchens, bathrooms, boiler rooms, ga-
rages etc. When installing the sensor make sure it will be heard from 
other rooms in the building as well. Carbon monoxide mixed with car-
bon dioxide is thicker than the air so it is recommended to install the 
sensor in the lower part of a wall. The recommended installation height 
for bedrooms is 0.5m above the floor. The optimal installation height for 
other rooms is 1.5m above the floor.

1. 

Separate the mounting base from the body of the device by turning 
it anti-clockwise.

2. 

Insert two AAA 1.5V batteries into the device.

3. 

Test the device by pressing the button on the cover for a few se-
conds. If the device works properly, interrupted signals should be he-
ard from the speaker.

4. 

Mark 2 spots for mounting bolts in the desired location, using the 2 
holes in the mounting base. Then, drill 2 holes of the proper diameter 
in the wall and insert the mounting bolts (included). Mount the base 
on the wall using the screws. Attach the body of the device to the 
base using 2 hooks in the body, matching the two oblong holes of 
the corresponding size, located in the base. When the elements are 
fitted turn the body to the right.

5. 

Press the TEST button at the side of the cover. The device will run the 
test procedure, testing the audible signalization of the alarm. If the 
signal is "beep" 0.5 s - pause - 0.5 s etc., and the red LED is not blinking 
or is constantly lit, this means that the device is damaged. Contact 
the technical support of the importer.

Содержание SC/1B

Страница 1: ...TECHNICAL SUPPORT tel 48 71 31 59 068 Manuall Carbon monoxide alarm SC 1B ...

Страница 2: ...1 5V Power consumption in alarm state 100 µA Power consumption in standby state 8 µA Allowable relative humidity 15 90 RH Detector type electrochemical Alarm format a series of 4 short signals at 0 5 sec interval and LED signalling Alarm volume 85dB 1m Tested alarm concentration 300 ppm alarm below 3 minutes Range of working temperatures 10 C 40 C Carbon monoxide alarm SC 1B constantly monitors th...

Страница 3: ... is 1 5m above the floor 1 Separate the mounting base from the body of the device by turning it anti clockwise 2 Insert two AAA 1 5V batteries into the device 3 Test the device by pressing the button on the cover for a few se conds If the device works properly interrupted signals should be he ard from the speaker 4 Mark 2 spots for mounting bolts in the desired location using the 2 holes in the mo...

Страница 4: ...bility of early detection of the dangerous concentra tion It is important to test the device as specified in the manual and to check periodically the chimney and ventilation ducts which can be the source of carbon monoxide The average service time of the installed sensor is approx 5 years from the first use of the device After that time the sensitivity of the sensor can decrease dramatically 1 Mak...

Страница 5: ...which makes the combined density of the combu stion gases higher than the air so they accumulate in the lower parts of the rooms There is no exact value above which the concentration of carbon monoxide is dangerous It depends on the time of inhaling the gas Inhaling the carbon monoxide at 200 ppm for 2 3 hours will cause a light headache nausea and dizziness The concentration of 12800 ppm will cau...

Отзывы: