background image

- 2 - 

OPERATION INSTRUCTIONS

 

 

 

1.

 

SECURE BY 2 MOUNTING SCREW ATTACHED TO THE WALL. 

 
2.

 

LIGHT SWITCH:                 

:ON 

 

3.

 

ON/OFF SWITCH

                   

:ON

 

 
4.

 

SPEED SWITCH OF RIGHT BLOWER MOTOR. 

   R: O        I : SLOW      II : FAST 

 
5.

 

SPEED SWITCH OF LEFT BLOWER MOTOR. 

   L: O        I : SLOW      II : FAST 

 
6.

 

LIGHT COVER.   

 
7.

 

COVER.   

 
8.

 

SAFETY NET.   

 
9.

 

OIL CUP.   

 
10.

 

COVER OF THE TOP    EXHAUST OUTLET. 

 
11.

 

COVER OF THE BACK EXHAUST OUTLET. 

 

 

Содержание Vetro SV156 -30/36"

Страница 1: ...Spagna Vetro Range Hood Under cabinet Model SV156 30 36 Users Manual 7272 Buller Ave Burnaby BC Canada Tel 604 430 5252 www KitchenHoods ca ...

Страница 2: ...er The Range Hood will not be effective B Height of installation The height of installation is measured form the button of Range Hood to top of stove the recommended height is 28 30 C Keep the hood in level Make sure the hood is in level when install Note The manufacturer import wholesaler will not be hold responsible for any damages to personal property or real estate or any bodily injuries Wheth...

Страница 3: ...E WALL 2 LIGHT SWITCH ON 3 ON OFF SWITCH ON 4 SPEED SWITCH OF RIGHT BLOWER MOTOR R O I SLOW II FAST 5 SPEED SWITCH OF LEFT BLOWER MOTOR L O I SLOW II FAST 6 LIGHT COVER 7 COVER 8 SAFETY NET 9 OIL CUP 10 COVER OF THE TOP EXHAUST OUTLET 11 COVER OF THE BACK EXHAUST OUTLET ...

Страница 4: ...as possible If turns or transitions are required Install as far away from opening and as far apart between 2 as possible Minimum mount height between stove top to hood bottom should be no less than 27 inch Maximum mount height between stove top to hood bottom should be no higher than 30 inch It is important to install the hood at the proper mounting height Hoods mounted too low could result in hea...

Страница 5: ... sure that the range hood is properly grounded DO NOT have a fuse in the neutral or ground circuit IMPORTANT Save this Installation Guide for electrical inspector s use The range hood must be connected with copper wire plug only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armoured or non metallic sheathed copper cable Listed strain re...

Страница 6: ...e using a single motor it is normal that the ripple effect will cause the other fan to move 2 The function of the activated charcoal filter is to remove oil and soot result from cooking However Oil and Soot will not be completely eliminated as this will cause the performance of the hood to reduce significantly Please refer to Pt A above For the most efficient quiet operation Range hood A distance ...

Страница 7: ...s The bulb does not light 1 Check whether the bulb is broken 2 Check whether the switch is damaged The motor does not rotate 1 Check whether the switch of the motor is damaged 2 Replace the motor if the switch is damaged Range Hood vibrates Check whether the blower is damaged Replace the damaged blower ...

Страница 8: ... 7 WIRING DIAGRAM ...

Страница 9: ...CKING DIMENSION 30 321 5 61 10 224 5 36 381 5 61 10 224 5 ELEC SPECIFICATION 120V 60Hz EXHAUST DUCT 6 dia or 81 2 21 2 TRANSMISSION STYLE Twin Motors LIGHTING SYSTEM 2 x 40 W Max VOLUME 800 CFM SPEED RANGES 1650 RPM CURRENT 3A For twin motors WEIGHT 30 N W 10 5 KG G W 12 5 KG ...