In marking location for room terminator (see Figure
2.19), the center of the terminator should be 5" from
the wall or, when installed in the corner of a room 5" from
both walls.
After marking location, drill a
1
⁄
8
" diameter hole for outlet
to be sure there is at least a 2" clearance all around
the
1
/
8
" hole to receive tubing and connector. Adjust
direction of hole as needed, to gain this 2" clearance.
After all clearances have been checked, take a 4"
diameter rotary-type hole saw and cut a hole, using the
1
⁄
8
" diameter hole as a pilot.
Assemble the room terminator to the sound attenuating
tubing by simply fitting the two pieces together and
twisting until tight (see Figure 2.20). If the terminator is
to be used in a floor location, then field fabricate a small
screen (1
1
⁄
2
" square;
1
⁄
4
x
1
⁄
4
20-gauge galvanized wire
screen) and place screen over opening on the back
of the terminator prior to twisting on the kwik-connect
(on the sound attenuating tube).
NOTICE: Do not shorten sound attenuating tube
length. The result would be unacceptable noise.
Push the free end of the sound attenuating tube through
the 4" hole until the two toggle springs on the room ter-
minator snap into place.
15
IN
INSULA
ULATION 3/8
3/8 NOMINAL
MINAL
SHEET
SHEET ROCK
ROCK
SOUND
SOUND ATTENUATOR
ATTENUATOR
3.500
500
0.625
625
3/16
3/16 GA
GAP
FOR
FOR APP
APPLICATIONS
ICATIONS WITH
ITH
THICKER
THICKER WAL
WALLBOARD
BOARD,
RE
REMOVE MATERIAL FROM
OVE MATERIAL FROM
THIS A
THIS AREA TO ALL
EA TO ALLOW FOR
W FOR
PROPER
PROPER FIT.
T.
SPL-0050-A
FIGURE 2.18: INSTALLATION WITH KWIK
CONNECT WALL ELBOW
SOUND
ATTENUATING
TUBE
THIS RADIUS
TOO SHORT
STUD SPACE
TERMINATOR
DRY WALL
OR PLASTER
FIGURE 2.17: INCORRECT TUBING INSTALLATION
Room Terminator & Sound Attenuating Tubing
Installation
Room terminators and pre-assembled sound attenuating
tubes are provided in the Installation Kits.
NOTICE: Do not install terminators in a wall in which
a sharp bend in the sound attenuating tube is
required (see Figure 2.17). The result would be
unacceptable noise.
OPTION: Using a SpacePak Kwik Connect Wall Elbow
(Model Number: AC-KCWE) addresses this condition
(see Figure 2.18).
4" DIA.
5"
5"
FIGURE 2.19: TERMINATOR MEASUREMENTS