GENERAL INFORMATION 

 

This  is  a  self-contained  agricultural  air  heater  for  use  in  locations  where  flammable  gases  or  vapors  are  not 
generally  present  and  is  intended  for  heating  of  agricultural  animal  confinement  buildings.  The  intended  use  is 
heating of agricultural animal confinement buildings. 

 

INSTALLATION REQUIREMENTS 
Installation  of this heater must be in  accordance with  all applicable codes shown  in  the instructions and/or the 
local  codes  and  authorities  having  jurisdiction.  In  the  UK  all  equipment  must  be  installed  and  maintained  in 
accordance with the relevant provisions of the Gas Safety (Installations and Use) Regulations 1998 for gas fired 
products. Installation practices must take into account the Health and Safety at Works Act 1974 or relevant codes 
of practice. In addition the installation must be carried out in accordance with the current IEE wiring regulations BS 
7671-latest revision, BS 6896-latest revision (Industrial & Commercial) and any other relevant British Standards 
and  Codes  of  Practice  by  a  qualified  installer.  All  external  wiring  MUST  comply  with  the  current  IEE  wiring 
regulations. 
Clearances  to  combustibles  as  outlined  in  the  manual  should  always  be  observed.  In  areas  used  for  storage of 

combustible materials where they may be stacked below the heater, the installer must post signs that will “specify 

the maximum permissible stacking height to ma

intain the required clearances from the heater to combustibles.”

 

Every heater shall be located with respect to building construction and other equipment so as to permit access to 
the control housing.  Each  installer shall use skillful and reliable installation  practices when  locating  the heaters 
and must give consideration to service accessibility. 
This  heater  is  for  either  INDOOR  or  OUTDOOR  INSTALLATION  and  is  used  in  an  UNVENTED  mode.  The  term 

Unvented 

actually  means 

Indirect  Vented

.  While  the  products  of  combustion  are  expelled  into  the  building, 

national codes require ventilation in the building to dilute these products of combustion. This ventilation must be 
provided by gravity or mechanical means. Ventilation requirements are addressed further in these instructions. 
Although these heaters may be used in many applications other than space heating (e.g., process heating), Space-
Ray will not recognize the warranty for any use other than space heating. 
This  heater  is  not  an  explosion  proof  heater.  Where  the  possibility  of  exposure  to  volatile  and  low  flash  point 
materials exists, it could result in property damage or death. This heater must not be installed in  a spray booth 
where the heater can operate during the spraying process. Consult your local fire marshal or insurance company. 
Before installation, check that the local distribution conditions, nature of gas and pressure, and adjustment of the 
appliance are compatible. 
 
This heater must be applied and operated under the general concepts of reasonable use and installed using best 
building practices. 
 
It is the responsibility of the qualified installer to supply the appropriate lifting equipment to safely install the 
agricultural air heater. Tools required for the safe installation, startup and maintenance are various screwdrivers, 
wrenches, pipe wrenches, volt and multi-meter, air and gas manometer and required tools to safely install the 
chosen hanging materials. 
 

This appliance can be used by children aged from 8 years and above and persons with 
reduced physical, sensory or mental capabilities or lack of experience and knowledge if 
they have been given supervision or instruction concerning use of the appliance in a 
safe way and understand the hazards involved. Children shall not play with the 
appliance. Cleaning and user maintenance shall not be made by children without 
supervision. 
 
Children must be supervised not to play with the appliance. 

 
 
 
 
 
 
 

Содержание VF80-L5 DSI

Страница 1: ...n monoxide an odorless and poisonous gas CARBON MONOXIDE POISONING MAY LEAD TO DEATH Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness and nausea If you experience the...

Страница 2: ...nt thinner dust particles or unknown chemicals Failure to follow these instructions may result in a fire or explosion property damage personal injury or loss of life FIRE AND EXPLOSION HAZARD Not for...

Страница 3: ...ARD The barns must be ventilated sufficiently for the present equipment and livestock Heater ventilation requirements are outlined in the Ventilation Section of this manual Inadequate ventilation will...

Страница 4: ...NG 18 14 1 MOTOR AND BLOWER ASSEMBLY 19 14 2 AIR PROVING SAIL SWITCH 19 14 3 IGNITION CONTROL MODULE DSI 19 14 4 TRANSFORMER 20 14 5 HIGH TEMPERATURE LIMIT SWITCH 20 14 6 FLAME SENSOR 20 14 7 SPARK EL...

Страница 5: ...is manual to indicate important safety information Warning instructions must be followed to prevent or avoid hazards which may cause serious injury property damage or death Caution instructions must b...

Страница 6: ...LATION and is used in an UNVENTED mode The term Unvented actually means Indirect Vented While the products of combustion are expelled into the building national codes require ventilation in the buildi...

Страница 7: ...s are posted on the burner box In areas used for storage of combustible materials where they may be stacked below the heater NFPA54 requires that the installer must post signs that will specify the ma...

Страница 8: ...liters per hr Natural Gas 7 0 m3 hr ELECTRICAL SUPPLY 230 Vac 1 Phase 50Hz TOTAL AMP DRAW 2 0A MOTOR RATING 1 4HP 1100 rpm AIRFLOW DELIVERED 1 700 m3 h The minimum inlet gas supply pressure for the p...

Страница 9: ...Form No 43539480 May 2021 8 6 0 DIMENSIONS Model No W width D depth H height VF80 N5 DSI 779mm 465mm 722mm VF80 L5 DSI...

Страница 10: ...r etc 6 Heaters must not be supported by gas or electric supply lines and must be suspended from a permanent structure with adequate load capacity 7 Locate the heater away from livestock so that they...

Страница 11: ...usage Check with the authorities having jurisdiction and or local codes prior to choosing an individual gas connection method 8 The gas pipe flexible hose and connections must be self supporting The...

Страница 12: ...trap see figure below must be installed in the gas line at a point before the air heater The sediment trap must be installed vertical to properly function b This sediment trap or drip leg acts to tra...

Страница 13: ...per square inch are not accurate enough to measure or set the manifold pressure All measurements MUST BE made when this heater and all other gas burning equipment that is connected to the gas supply s...

Страница 14: ...tional harmonized 3 wire PVC thermoplastic jacket supply cable with earth 0 75 mm2 to National or Local standard specifications connect the power supply leads to the terminal block and earth connectio...

Страница 15: ...ions DSI S1 Flame sensor GND 24Vac transformer ground to module V2 24Vac transformer ground to Gas valve 24 VAC 24Vac supply to module L1 HOT 230Vac supply to module IND 230Vac supply to blower motor...

Страница 16: ...pre purge for 3 seconds and spark for 10 seconds Turn the thermostat or power off for 60 seconds to take the system out of lockout 5 If the heater does not light manually reset the thermostat or shut...

Страница 17: ...propriate cycle when heating the building to avoid high concentrations of carbon monoxide and water vapor The temptation particularly during the winter months is to close up the heated space to conser...

Страница 18: ...liance area is kept clear and free from combustible materials gasoline and other flammable vapors and liquids Insulated Air Duct Disconnect air ducting if equipped and inspect internally using a flash...

Страница 19: ...the heater may have been hit accidentally and tighten any loose hanging points Check that S hooks are closed Check that there is no evidence of wear on the chain threaded rod or other suspension metho...

Страница 20: ...the motor and blower assembly and clean the impellor with compressed air If vibration persists the impellor needs replacing 14 2 AIR PROVING SAIL SWITCH The air proving sail switch is not serviceable...

Страница 21: ...ontinuity after the red reset button has been pressed Annual test be careful the switch will be hot in some areas To test the operation of the high temperature limit switch remove it and hold a small...

Страница 22: ...e pressure on the outlet side of the gas valve after energizing the gas valve Replace if necessary 14 9 BURNER ORIFICE Inspect the burner orifice for dirt or insect debris Clean the orifice hole with...

Страница 23: ...et screw torque to 16 3 Nm onto the flat side of the motor shaft 6 To replace the motor remove the blower wheel as described in 5 7 Remove the 4 hex nuts from the motor and slide away from the motor p...

Страница 24: ...it 4 Replace module in reverse order Note Refer to the wiring connection diagrams in section 9 0 15 4 REMOVAL OF TRANSFORMER DSI MODELS Replacement procedure 1 Rotate the latching knob and open the sm...

Страница 25: ...he large size door at the burner gas valve compartment 2 Disconnect the lead wires from the limit switch 3 Remove the 2 sheet metal screws holding the high temperature limit switch and remove it 4 Rep...

Страница 26: ...ctrode and remove it 4 Replace this in reverse order Note Refer to the wiring connection diagrams in Section 9 0 15 8 REMOVAL OF GAS VALVE AND BURNER ORIFICE DSI MODELS Replacement procedure 1 Rotate...

Страница 27: ...emove the screw attaching the ground wiring onto the burner 3 For Pilot models disconnect the pilot assembly from the main burner by removing the wing screw 4 Remove the machine screw and washer from...

Страница 28: ...Form No 43539480 May 2021 27 16 0 TROUBLESHOOTING 16 1 TROUBLESHOOTING CHART DSI...

Страница 29: ...Form No 43539480 May 2021 28 TROUBLESHOOTING CHART DSI continued...

Страница 30: ...Form No 43539480 May 2021 29 17 0 REPLACEMENT PARTS GUIDE...

Страница 31: ...50 Plate Burner Mounting Heater 250K 1 18 50000100 Bolt Carriage 10 24 7 1 2 W Short Square 302 SS 2 19 50000250 Nut Hex Serrated Flange 10 24 SS 2 19a 02167040 Nut Hex 8 32 SS 2 20 44597010 Plate Blo...

Страница 32: ...odulating NG 1 2 NPT 1 57 44601500 Bracket Gas Valve HW VR8215M 250K Heater 1 57a 50000040 Bolt Hex Cap 3 8 16 X 3 4 Zinc 1 58 50000180 Screw Sheet Metal 8 X 3 8 410 SS Slotted Hex Head 84 59 50000190...

Страница 33: ...l Lighting Shutdown DSI 1 89 44593610 Label Wire Diagram DSI 1 90 44603000 CARTON not shown 1 Note 1 Screws Nuts and Washers are standard hardware items and can be purchased at any local hardware stor...

Страница 34: ...Form No 43539480 May 2021 33...

Страница 35: ...Form No 43539480 May 2021 34...

Страница 36: ...Form No 43539480 May 2021 35...

Страница 37: ...where any acid or acid based product causes damage to the metal components or e any heater or component part which has been repaired or replaced with other than factory parts modified in any way misu...

Страница 38: ...ed Products Inc 1700 Parker P O Box 36485 Charlotte NC 28236 Phone 704 372 3488 Fax 704 332 5843 email info spaceray com FOR YOUR RECORDS Space Ray Brooder Model Number ______________________________...

Отзывы: