3.1.
Loosen and remove the 1/213 hex nut and washer from the heater assembly.
3.2.
Lift the head from the heater.
3.3.
Place reflector on outside of expanded metal guard with bottom edge inside lip of the base head
assembly.
3.4.
Replace upper head with lip over the expanded guard and reflector.
Hex Nut
1/2-13
Washer
Upper
Head
Heat
Exchanger
Welded
Base
Assembly
Reflector
SECTION 4: MINIMUM CLEARANCES TO COMBUSTIBLES
The heater shall be operated only on a NON-COMBUSTIBLE, level floor. Minimum clearances to combustible
walls and ceilings are listed below:
Table 3: RFPA10C Clearances to combustibles.
MODEL RFPA10C
FRONT
SIDES
REAR
TOP
CLEARANCE FROM
PROPANE CYLINDER
WITH REFLECTOR
120"
60"
48"
54"
10 FEET
WITHOUT REFLECTOR
----
60"
----
54"
10 FEET
Содержание RFPA10C