Model
System
capacity
(Nom. Tons)
Suction
Line (O.D.)
Liquid
Line (O.D.)
Cond.
Drain
(FPT)
Return
Inlet
(Dia.)
Connections
Recommended
Condensing Unit
Nominal
Capacity
(MBH)
Min
SEER
ESP-2430G
ESP-3642G
ESP-4860G
2 - 2-1/2
3 - 3-1/2
4 & 5
Electrical
Characteristics
208-230/60/1
208-230/60/1
208-230/60/1
7/8"
7/8"
7/8"
3/8"
3/8"
3/8"
3/4"
3/4"
3/4"
15"
19"
24"
24 to 30
36 to 42
48 to 60
13+
13+
13+
Model
System
capacity
(Nom. Tons)
Air Volume
@ 1.5" W.C.
(SCFM)
Motor
HP
F.L.
Amps
No. of
Rows
Deep
Blower
Holding
Charge
(Dry
Nitrogen)
Flow
Control
Type
Ship.
Wt.
(lbs)
ESP-2430G
ESP-3642G
ESP-4860G
2 - 2-1/2
3 - 3-1/2
4 & 5
550
1/3
1/2
1
PSC
PSC
PSC
1.8
2.8
5.3
6
6
6
7 psi
Exp. Valve
Exp. Valve
Exp. Valve
120
144
171
850
1150
Motor
Type
Coil
Wheel Dia.
and
Width
9" x 5"
9" x 6-3/8"
9" x 5"
7 psi
7 psi
6
SECTION 2: SYSTEM INSTALLATION
NOTICE: Before proceeding with the installation, we
recommend reading through this section of the
manual for an overall understanding of the air
conditioning fan coil unit and air distribution system
component installation procedures.
STEP 1: LOCATING THE UNIT
The fan coil unit may be installed in an unconditioned
space (as long as it is protected from the weather) such
as an attic, garage or crawlspace...or a conditioned
space such as a basement, closet or utility room (see
dimensions in Figures 2.2 and 2.3).
The fan coil unit is shipped in a horizontal air flow
arrangement, but can be easily field-converted to a
vertical air flow arrangement as detailed on page 9 and
Figures 2.8 and 2.9.
When selecting a location, consider the locations (as
shown in Figures 2.4, 2.5 and 2.6) of the return air box;
routing of the plenum duct, supply tubing, refrigerant lines,
condensate drain line; and all recommended clearances
(see Figures 2.2 and 2.3).
FIGURE 2.1: MODEL ESP-F SPECIFICATIONS
FIGURE 2.2: UNIT DIMENSIONS AND CLEARANCES (inches)