SC-CF-SBD Owner’s Manual
24
Pump 1
Output Configuration
Configuration
of Pump 1
1) Locate the pump 1
connectors.
2) Using a pair of long-nose
pliers, unplug the white
wire of the pump 1
connector from the
board. (P7)
3) Reconnect the white
wire to the P18 (connec-
tor) and make sure the
connector is properly
inserted.
Pump 1 is configured at the factory as a 120 V pump.
If you are using a 240 V pump, you must change the wiring
configuration. Perform the following steps: