62
Operating manual Soyer Bolzenschweißtechnik
12.1.5 Setting the lift time (height of lift) in the "Setup" mode
For drawn arc welding guns, the stud is lifted for a defined height/time just before the
welding process and automatically lowered again during the welding process.
As the height of lift of the stud is difficult to measure, the equivalent lift time is specified
on the stud welding device.
In the following setting of the lift time, the welding process is simulated in the "Setup"
mode. The lifting and lowering of the stud is the same as during welding, only the
welding current is not activated.
Operating modes
Setup mode: No welding is carried out when simulating a welding process.
Operating mode (normal mode): Welding is carried out.
Danger from incorrect operating mode
If the following adjustment work is not carried out in the setup mode but in the
operating mode, pressing the trigger button on the gun causes a weld to be carried
out.
Make sure that the "Setup" mode is activated for the lift test.
Setting the lift time/height of lift with the stud welding device
Step 1:
Connect the device as described in chapter
welding device and the stud welding guns
Switch on the device.
Step 2:
Fit the gun with a welding stud.
Step 3:
Use the ↑↓ arrow keys to select the
position for the lift test.
The LED lights up if the selection is
correct.
Содержание BMK-10i
Страница 2: ......