Soyal LK-1201B Скачать руководство пользователя страница 3

LK-1201B SETTING                                            

 
1.  Operation Delay time 

You could set up “Operation Delay time” by the Switch Device at the 

bottom of LK-1201B directly. For example, if you set time to be 3 seconds, 

when lock sensor dedicated the door status is close, it will auto re-lock in 3 

seconds.   

       

 

 

 

 

 

 

 

 
2.  Wiring 

Operation Delay time setting 

0 Sec.   

3 Sec.   

6 Sec.   

9 Sec.   

Color 

Red Black Yellow  Blue White

Gray 

Purple 

Brown 

Function 

 

DC 12V+  GND 

Push 

Button 

(connect 

Black) 

COM

N.O. N.C. COM  N.O. 

 
3. LED Indicators 

Normal Status Indicator 

Unusual Status Indicator 

LED status  Description 

LED status Description 

Red   

Door opened. 

Red light 

flashing 

Door closed but lock not be 

locked. 

Green Door 

closed. 

Green light 

flashing 

Door closed but lock core not 

yet. (equal to DIP switch 

delay time) 

Orange 

light 

flashing 

If someone moves lock core 

after door closed, alarm will 

occur. 

 
 
 
 
 
 

www.soyal.hu 