![Soyal LK-1201B Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/soyal/lk-1201b/lk-1201b_quick-start-manual_1338276003.webp)
LK-1201B SETTING
1. Operation Delay time
You could set up “Operation Delay time” by the Switch Device at the
bottom of LK-1201B directly. For example, if you set time to be 3 seconds,
when lock sensor dedicated the door status is close, it will auto re-lock in 3
seconds.
2. Wiring
Operation Delay time setting
0 Sec.
3 Sec.
6 Sec.
9 Sec.
Color
Red Black Yellow Blue White
Gray
Purple
Brown
Function
DC 12V+ GND
Push
Button
(connect
Black)
COM
N.O. N.C. COM N.O.
3. LED Indicators
Normal Status Indicator
Unusual Status Indicator
LED status Description
LED status Description
Red
Door opened.
Red light
flashing
Door closed but lock not be
locked.
Green Door
closed.
Green light
flashing
Door closed but lock core not
yet. (equal to DIP switch
delay time)
Orange
light
flashing
If someone moves lock core
after door closed, alarm will
occur.
www.soyal.hu