V100630
AR-321H
AR-321H
AR-721E
N.C.
N.O.
COM
CTL
12V
4 3 2 1
2 1
N.C.
N.O.
COM
CTL
12V
AR-721E
P6
P1
DO 3
DO 2
12V
GND
AR-721E
P3
COM
DI 2
DI 1
N.O.
N.O.
4 3 2 1
8 7 6 5
12 11 10 9
EXIT
BZ
GLED
RLED
WG 1
WG 0
GND
12V
N.C.
COM
12 11
GND
12V
N.C.
N.C.
N.C.
N.O.
N.O.
N.O.
AR-721E
P2
GLED
N.C.
N.O.
N.C.
N.C.
N.C.
N.O.
AR-721E
P5
GLED
3 2 1
4 3 2 1
8 7 6 5
12 11 10 9
EXIT
BZ
GLED
RLED
WG 1
WG 0
GND
12V
N.C.
COM
2 Door WG Controller
Connect to Electric Strike
P2
About Digital Input
P3
Notice
Connect to Magnet Lock or Electric Bolt
P5
About Transistor Output
P6
Electric Bolt
or
Magnet Lock
Push Button
Push Button
Electric Strike
POWER
12VDC
POWER
12VDC
POWER
POWER
12VDC
Door Sensor
Door Sensor
Reader A
Tamper Switch
Tamper Switch
Reader B
Reader
Equipment
Equipment
Relay Outpot Module
Relay Outpot Module
If the Power line more than 100 m between the Controller and Reader, it is recommended
NOT
to use the "
Wiegand Power
".
See connection mode within the dashed box , Controller and Reader must to do "
common-COM-point
".
Adding and Deleting Tag
Add Single Tag or Random tags
Input 123456 (or Master Code)
19 UUUUU 00001
Present the tag(s) with reader
(single tag or random numbered cards one by one)
Done
[e.g.] 2 readom cards with user addresses No. 100 and No. 101:
Access programming mode
19 00100 00001
Present the tags one by one
Done
Input 123456 (or Master Code)
19 UUUUU QQQQQ
Present the tags
(Present the tag with the
lowest number
OK
Add the Sequential tags
[e.g.] User Address NO.101 to NO.120 have 20 pcs of sequential tags:(62312~62332)
:
Access programming mode
19 00101 00120
Close Tag into RF Area
(only use the tag
NO.62312
)
OK
Delete All Tags
Input 123456 (or Master Code)
29 29
Delete a Single Tag
Input 123456 (or Master Code)
10 SSSSS EEEEE
[e.g.] Delete User Address: 00058
Access programming mode
10 00058 00058
9
9
Delete a batch of Tags
Input 123456 (or Master Code)
10 SSSSS EEEEE
[e.g.] Delete User Address: 00101~00245
Access programming mode
10 00101 00245
9
9
Tag Information
SITE CODE
CARD CODE
SITE CODE
CARD CODE
Enter the program mode
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input
876112
program mode accessed
Operation process
A. Enter/ Exit Program Mode
Exit the program mode
Input
Access programming mode
09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] Set the Master code to be 876112, input
123456
09 876112876112