Soyal AR-837 E Скачать руководство пользователя страница 5

SOYAL

ACCESS CONTROL SYSTEM

®

AR-837 (E) / (EF)

V140217

   

H. Arming Password

J. Duress Code

K. Terminal Port

I. Arming Delay Time

Access programming mode

 →  

 

  

Parameters[1]

 →     

Arming PWD

 → 

Input 4-digit PIN (0001~9999; Default: 1234)

 → 

Succeeded

  

Or via 701Server and set it on  AR-829E  screen

3

8

Or via 701Server to set it on  AR-829E-V5  screen

Duress Code is only available in networking mode. It will substitute a personal pin code and send the message of Duress to computer as a    

    warning signal.

Access programming mode

 →  

 

  

Parameters[2]

 →     

Duress Code

 → 

4 sets (select one)

 → 

Input 4-digit PIN (0001~9999)

 → 

Succeeded

  

4

7

Access programming mode

 →  

 

  

Tools

 →     

Terminal Port

 → 

0:Lift ; 1:Host ; 2:LED ; 3:PRN (default value:1) 

→ 

Baud Selection 

(default value:9600)

 → 

Succeeded

  

5

4

L. Setting up the alarm / arming

Conditions:

1. Arming enabled
2.Alarm system connected

Situations:
1. Door is open overtime

: Door is open longer than door relay time plus door close time.

2. Force open

 (Opened without a valid user card): Access by force or illegal procedure.

3. Door position is abnormal

: Happening when power is off and then on again, besides, reader was on arming before power went off.

Enable/Disable the arming status:

Standby Mode

Access Programming mode

Card only

Card or PIN

Card and PIN

Open the door
Present the tag to reader

 → 

Input 

4-digit arming PWD

 →

Input user address

 → 

Input 

4-digit individual PWD

 →      → 

Input 4-digit arming PWD

 →

Present the tag to reader

 → 

Input 

4-digit individual PWD

 →      → 

Input 4-digit arming PWD

 →

Enable:

 Access programming mode

 →     

Quit & Arming

7

Disable:

 Access programming mode

 →     

Quit

6

No open the door

     → 

Input 4-digit arming PWD

 

→ 

Present the tag to reader

Access programming mode

 →     

Parameters[1]

 →     

ArmingDelayTm

 → 

Enter armed sta. Delay time(Sec), Range:000~255

Armed pulse out-put time (10ms) ,Range

000~255

 → 

Succeeded

  

3

7

※ 

[Use FP] can substitute for [Induct valid card].

F. Adding / Deleting Fingerprint 

Adding

Access programming mode

 →  

 

  

User Setting

 →    

 Enroll FP

 → 

Key in 5-digit user address

 →

1 or 2 different fingers on the sensor lens 

→ 

Succeeded

P.S. The AR-837EF needs to collect twice for each fingerprint.

2

6

Deleting

Access programming mode

 →  

 

  

User Setting

 →    

 Delete FP

 → 

Key in 5-digit user address

 → 

Succeeded

P.S. If you want to delete all users’ FP, key in 

99999

2

7

#

G. Access Mode

Access programming mode

 →  

 

  

User Setting

 

→     

Access Mode

 

→ 

Key in 5-digit user address (00000~08999)

 

→ 

0: Invalid; 1:Card; 2: Card or PIN; 3: Card and PIN

 

(

837EF

: → 

Finger Identify: 0: Must ; 1: Ignore )

→ 

Succeeded

  

2

2

Access Mode

Finger Identify (837EF Only)

Result  (837EF Only)

Hardware

701Client

Hardware

701Client

0:Invalid

0: Must

 

       Just fingerprint

       Just card control

 

Invalid User

1: Ignore

       Just fingerprint

       Just card control

1:Card

0: Must

       Just fingerprint

       Just card control

 

Card

1: Ignore

       Just fingerprint

       Just card control

 1. Card Only

 2. Finger Only

2:Card or PIN

0: Must

       Just fingerprint

       Just card control

 1. Card

 2. PIN

 3. Card+PIN

 4. Card+Card

 5. PIN+PIN

 6. PIN+Card

1: Ignore

       Just fingerprint

       Just card control

 1. Card Only

 2. PIN Only

 3. Finger Only

3:Card and PIN

0: Must

       Just fingerprint

       Just card control

 Card+PIN

1: Ignore

       Just fingerprint

       Just card control

 1. Card+PIN

 2. PIN

837E-EF-140217.indd   5

2014/12/17   下午 04:05:20

Содержание AR-837 E

Страница 1: ...ck Blue RS 485 A Cable CN6 P4 WireApplication Wire Color Description Door Bell 1 Black White Transistor Output Max 12V 100mA Open Collector Active Low 2 Black DC 0V Cable 7 CN13 P7 WireApplication Wir...

Страница 2: ...ed Arming Green OK Green Error Red In processing Green Networking and interactively flash between the Month and DAY e g 12 07 12 07 Stand alone No flashing e g 12 07 Reference to picture Connect to El...

Страница 3: ...2VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC Electric Strike Door Contact Strengthen security with AR 721RB Electric Bolt Electric Bolt Electric Bolt Fire Emergency Tra...

Страница 4: ...digit user address Input Tag Units pcs Close Tag into RF Area If the batch of tags are Sequential input Tag Units pcs in the quantity of the tags and present the tag with the lowest number to the con...

Страница 5: ...t Arming 7 Disable Access programming mode Quit 6 No open the door Input 4 digit arming PWD Present the tag to reader Access programming mode Parameters 1 ArmingDelayTm Enter armed sta Delay time Sec...

Страница 6: ...etting Multi Floor Input 5 digit user address Select range 1 or 2 or 3 or 4 Input 16 digits multi floors number 0 disable 1 enable e g Set NO 114 can use it through the 8 F and 16F Access programming...

Страница 7: ...User Setting 1 Password 2 Access Mode 3 Extend Options 4 Single Floor 5 Multi Floor 6 Enroll Finger 7 Delete Finger 1 Add Delete 1 Add Card ID 2 Add RF Learn 3 Suspend Address 4 Suspend ID 5 Delete Ad...

Страница 8: ...ticker on Ethernet Module device Please alter the IP address as you want and then click Update button After updating the IP please re connect the Web Browser by the new IP address User Password The pa...

Отзывы: