V091119
M1
Board
Horn
M2
1
2
3
4
5
6
7
8
N.C.
N.O.
COM
CTL
12V
ALM
12V
GND
GND
P1
LCD Access Controller
F. Lift control
G. Alarm Clock (for Factory)
Connect with
AR-401RO16B
to control which floors the user will be able to access.
Output to
M1
and
M2
Mike device
Mike device
Music Box
Music Box
Mike's sound wire
Mike's sound wire
DC 12V Relay Board
Access programming mode
→
Tools
→
Terminal Port
→
1
:
AR-401RO16
5
4
Setting Lift control
Hardware installation
Software Setting
Access programming mode
→
User Setting
→
Single Floor
→
Input 5-digit user address
→
Input single floor number: 1~64
2
4
Single floor
Access programming mode
→
User Setting
→
Multi Floor
→
Input 5-digit user address
→
Select range: 1 or 2 or 3 or 4
→
Input 16 digits
multi floors number [0:disable, 1: enable]
[i.e.] Set NO. 114, can use it with the 8 F and 16F:
Access programming mode
→
User Setting
→
Multi Floor
→
114
→
1
→
0000000100000001
2
2
5
5
Multi floors
Set Floor/ Stop
1
0
17
0
33
0
49
0
9
0
25
0
41
0
57
0
1
2
3
4
3
0
19
0
35
0
51
0
11
0
27
0
43
0
59
0
2
0
18
0
34
0
50
0
10
0
26
0
42
0
58
0
4
0
20
0
36
0
52
0
12
0
28
0
44
0
60
0
5
0
21
0
37
0
53
0
13
0
29
0
45
0
61
0
6
0
22
0
38
0
54
0
14
0
30
0
46
0
62
0
7
0
23
0
39
0
55
0
15
0
31
0
47
0
63
0
8
1
24
0
40
0
56
0
16
1
32
0
48
0
64
0
The AR-821E/AR-829E controller can support up to 12 sets of ring per day
1. Click [82X] to [829E/821E Parameter Setting]
2. Select target node of AR-829E
3. Click [Read From Controller] to read the parameters of target 829E
4. Press [Daily Time Schedule] to start weekdays and timing settings
5. Select [SUN to MON]
6. Set up [Event] for timing to ring the bell and set up [Sec.] for activating time
of ring. (Range: 01~44 seconds; if you set 0 second there will not be action.)
7. Click [Yes] after setting
8. Click [Write To Controller] to end Setting
7
8
6
3
4
5
2
1
Manu Tree
5. Tools
1. Language
2. Master Code
3. Master Range
4. Terminal Port
5. AR401RO16 Node
6. Open Time Zone
7. Informations
8. Clock Setting
6. Quit
7. Quit & Arming
4. Parameters[2]
1. Auto Relock
2. Egress(R.T.E)
3. Attendance
4. Master Node
5. Force Open
6. Close & Stop
7. Anti-pass-back
8. Duress Code
3. Parameters[1]
1. Node ID
2. Auto open Zone
3. Door Relay Tm
4. Door Close Tm
5. Alarm Relay Tm
6. Alarm Delay Tm
7. Arming Delay Tm
8. Arming PWD
2. User Setting
1. Password
2. Access Mode
3. Extend Options
4. Single Floor
5. Multi Floor
1. Add/ Delete
1. Add > Card ID
2. Add > RF Learn
3. Suspend > Address
4. Suspend > ID #
5. Delete > Address
6. Delete > ID #
7. Recover > Address
8. Recover > ID #
9. Antipass Group
Controller
POWER
12VDC