SOYAL
®
AR-723 (H)
V200620
Access Controller
Enable:
Access programming mode
→
Disable:
Access programming mode
→
Factory Reset by its commands
When the device is stand-alone (not networking)
Access programming mode
→
20
016
→
24
064
→
26
00000
01023
1
→
28
000
→
29
29
※
Note: After the Master Code is changed, factory reset doesn’t restore the Master Code back to 123456.
Enable/Disable Arming status (for M4/M8; Factory default armingcode is: 1234) :
Standby Mode
Enter Program Mode
After door open
The normal procedure to open door
→
Input 4 digit arming code
→
Do not open the door
→
Input 4 digit arming code
→
Present valid card
※
[The normal procedure to open door] can refer to [Access Mode].
D. Setting Up the Arming
[Only for connect to external K-series reader]
Alarm conditions:
1. Arming is enabled
2.Alarm system connected
Application:
1. Door open too long
: Door is open longer than door relay time plus door close time.
2. Force open
(Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal
: Arming is enabled and the power is suddenly off then on.
Function Default Value
Mode4 / Mode6 / Mode8
※
Mode 6,
the number of users up to 65535, since it reads
CARD CODE
(5 digits) only, unlike that Mode4/Mode8 read
SITE CODE
and
CARD CODE
(10 digits).
If Access Mode setting to use the PIN,
it
need to external the K-series Readers.
Selection= 0(none value)/ 1(1 x each value)
[e.g.] DDD value of Enable “Auto Open” + ”Exit by Push ”Anti-pass-back”
=(0x1)+(0x2)+(1X4)+(1x16)+(0x32)+(0x64)+(1x128)=148 ; As a result of that, the command will be 20 148 .
20 DDD
※
Default Value
Function
Selection
Value Application
Attendance
※
0: Yes
1: No
001
Networking
Auto Re-lock
※
0: Disable
1: Enable
002
Networking/Stand-Alone
Auto Open
※
0: Disable
1: Enable
004
Networking/Stand-Alone
Door open button input
0: Disable
※
1: Enable
016
Networking/Stand-Alone
Master Controller of Network
※
0: Slave
1: Mater
032
Networking
24 DDD
※
Default Value
Function
Selection
Value Application
Auto-open door without cards at auto open zone
※
0: Disable
1: Enable
001
Networking/Stand-Alone
Alarm Output/ Lift Control
※
0: Alarm Output
1: Lift Control
002
Networking/Stand-Alone
Stop Alarm by door close or by push button
0: None
※
1: Yes
064
Networking/Stand-Alone
28 DDD
※
Default Value
Function
Selection
Value Application
Dual Door Control
※
0: Disable
1: Enable
064
Networking/Stand-Alone
Force Open Alarm Output
※
0: Disable
1: Enable
128
Networking/Stand-Alone
Mode Networking/
Stand-Alone
User
Capacity
Access Mode
Auto-show
Duty time
Event log
Capacity
120
Holidays
Anti
force
Time
Zone
Lift
Control
Anti-pass-
back
M4
Networking/
Stand-Alone
1,024
1.Card only
2.Card and PIN
(4-digit PIN)
+
3.Card or User address
(5-digit)
+ Individual PIN
(4-digit
individual PIN)
+
Yes
1,200
Yes
Yes
No
32
Yes
M6 Stand-Alone
65,535
1.Card only
2.Card and PIN
(4-digit public PIN= Arming PWD)
+
3.Card or PIN
(4-digit public PIN= Duress code)
No
No
No
No
No
No
No
M8
Networking/
Stand-Alone
1,024
1.Card only
2.Card and PIN
(4-digit individual PIN)
+
3.Card or PIN
(4-digit individual PIN)
Yes
1,200
Yes
Yes
No
32
Yes