Soyal AR-721KP Скачать руководство пользователя страница 2

V110810

    

   

Keypad 

Programming

C. Add a User Code to the system

B. Set up user number corresponding to door relay

D. Set the door relay-1 release time

E. Set time out value

F. Set keypad lock of continuous error operation 

Enable a (range of) User(s) Code to the system

Press

    

123456

     

(or Master Code)

 → 

11      SSS     EEE      

→ 

Done (A green light and beep means that the user code(s) was enabled. 

)

[e.g.] Enable User code

 

58 to the system

        

Access programming mode

 → 

11     058     058     

→ 

Done

[e.g.] Enable User code

 

1 to 10 to the system

        

Access programming mode

 → 

11     001     010      

→ 

Done

[e.g.] Set user code 123 to user 001

        

Access programming mode

 → 

12     001     123      

→ 

Done

Access programming mode

 → 

12     UUU      PPPPPP      

UUU(User address)

001~254

PPPPPP(User Code)

The user code must be 3 to 6 digits in length and the key # cannot be used in a code.

[e.g.] Set user code 123456 to user 002

        

Access programming mode

 → 

12     002     123456      

→ 

Done

Access programming mode

 → 

01     UUUU               UUUU=User address (Default value = 0250)

[User number 

0000~0249 

operates 

Relay_A

; User number 

0250~0499

 operates 

Relay_B

.]

Access programming mode

 → 

04      TT                  TT = 00~09 (0~0.9)

 

seconds; TT = 10~49 (1~4.9) seconds

Access programming mode

 → 

06      PPP              PPP = 000 (Disable) / PPP = 001 (Enable) [If use two access groups, places set 

disable

.]

G. Set Door bell   (     +     Door Ring)

Access programming mode

 → 

05      T                     T = 3~9 (times); T = 0 (Close this Function)

[e.g.] Set three incorrect user code are entered

Access programming mode

 → 

05      3      

→ 

Done 

A. Entering and Exiting Programming Mode

Changing the Master Code

Access programming mode

 → 

09     PPPPPPRRRRRR         [Input the 6-digit new master code twice.]

[e.g.] If want to changing the Master Code= 876112, input  

   

123456

     → 

09     876112876112

Exiting

Input

Entering

Input      123456      or      PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input  

   

876112

     → 

Access programming mode

Access programming mode

 → 

02     TTT     

                                                        Set door relay_B, enter 03.

TTT = 000 Latch(Toggle) / TTT = 001~600 (001~600) seconds.
TTT =601~609 (0.1~0.9) seconds.

Command List

Function

Command

Exposition

Entering programming mode

     PPPPPP

PPPPPP: Master Code, (Default value: 123456)

 Exiting programming mode

User number corresponding to door relay

01      UUUU

UUUU

User address, (Default value: 0250); User before the 

250

th

 is the first group, the other is the second group.

Relay_A time setting

02      TTT

TTT

Door relay time

000 (Output constantly)

001~600

1-600 Sec.

601~609

0.1~0.9 Sec.

Relay_B time setting

03      TTT

TTT

Door relay time

000 (Output constantly)

001~600

1-600 Sec.

601~609

0.1~0.9 Sec.

Set time out value

04      TT

TT

Keypad operate during time

Range

00 ~ 09

 (

0 - 0.9

Sec.

10 ~ 49

 (

1 - 4.9

Sec.

Set keypad lock of continuous error operation

05      T

T

Continuous error times

3 ~ 9 (Times)

T

0 (Disable)

Door bell

06      PPP

PPP

000 ( Disable ) / PPP

001 ( Enable )

Master code settings

09      PPPPPPRRRRRR

PPPPPP= New master code

RRRRRR= Repeat the new master code

Suspend or delete user code

10      SSS      EEE

SSS= starting user address ; EEE= ending user address

Recover user code

11      SSS      EEE

SSS= starting user address ; EEE= ending user address

Add a User Code to the system

12      UUU     PPPPPP

UUU

User address

PPPPPP

3 to 6 digits

Delete (Remove) a User Code

14      UUU

UUU

User address

Delete (Remove) all Users Codes

29      29

Factory Reset by its commands

If the master code is forgotten it can be restored to the factory default.  Remove the AR-721KP from the mounting plate.  Press and hold the reset switch 
5 seconds.  LED light green during 2.5 seconds and five beep sounds mean that master code have restored to the factory default 123456.

Delete (suspend) a (range of) User(s) Code from the system

 

Press

    

123456

     

(or Master Code)

 → 

10     SSS     EEE      

Done

 (

A green light and beep means that the user code(s) was disabled. 

)

[e.g.] Delete (suspend) User code

 

58

        

Access programming mode

 → 

10     058     058      

→ 

Done

[e.g.] Delete (suspend) User code

 

1 to 10

        

Access programming mode

 → 

10     001     010      

→ 

Done