![Soyal AR-721KP Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/soyal/ar-721kp/ar-721kp_user-manual_1338247002.webp)
V110810
Keypad
Programming
C. Add a User Code to the system
B. Set up user number corresponding to door relay
D. Set the door relay-1 release time
E. Set time out value
F. Set keypad lock of continuous error operation
Enable a (range of) User(s) Code to the system
Press
123456
(or Master Code)
→
11 SSS EEE
→
Done (A green light and beep means that the user code(s) was enabled.
)
[e.g.] Enable User code
58 to the system
:
Access programming mode
→
11 058 058
→
Done
[e.g.] Enable User code
1 to 10 to the system
:
Access programming mode
→
11 001 010
→
Done
[e.g.] Set user code 123 to user 001
:
Access programming mode
→
12 001 123
→
Done
Access programming mode
→
12 UUU PPPPPP
UUU(User address)
:
001~254
;
PPPPPP(User Code)
:
The user code must be 3 to 6 digits in length and the key # cannot be used in a code.
[e.g.] Set user code 123456 to user 002
:
Access programming mode
→
12 002 123456
→
Done
Access programming mode
→
01 UUUU UUUU=User address (Default value = 0250)
[User number
0000~0249
operates
Relay_A
; User number
0250~0499
operates
Relay_B
.]
Access programming mode
→
04 TT TT = 00~09 (0~0.9)
seconds; TT = 10~49 (1~4.9) seconds
Access programming mode
→
06 PPP PPP = 000 (Disable) / PPP = 001 (Enable) [If use two access groups, places set
disable
.]
G. Set Door bell ( + Door Ring)
Access programming mode
→
05 T T = 3~9 (times); T = 0 (Close this Function)
[e.g.] Set three incorrect user code are entered
:
Access programming mode
→
05 3
→
Done
A. Entering and Exiting Programming Mode
Changing the Master Code
Access programming mode
→
09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] If want to changing the Master Code= 876112, input
123456
→
09 876112876112
Exiting
Input
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input
876112
→
Access programming mode
Access programming mode
→
02 TTT
Set door relay_B, enter 03.
TTT = 000 Latch(Toggle) / TTT = 001~600 (001~600) seconds.
TTT =601~609 (0.1~0.9) seconds.
Command List
Function
Command
Exposition
Entering programming mode
PPPPPP
PPPPPP: Master Code, (Default value: 123456)
Exiting programming mode
User number corresponding to door relay
01 UUUU
UUUU
=
User address, (Default value: 0250); User before the
250
th
is the first group, the other is the second group.
Relay_A time setting
02 TTT
TTT
=
Door relay time
;
000 (Output constantly)
001~600
=
1-600 Sec.
;
601~609
=
0.1~0.9 Sec.
Relay_B time setting
03 TTT
TTT
=
Door relay time
;
000 (Output constantly)
001~600
=
1-600 Sec.
;
601~609
=
0.1~0.9 Sec.
Set time out value
04 TT
TT
=
Keypad operate during time
Range
:
00 ~ 09
(
0 - 0.9
)
Sec.
;
10 ~ 49
(
1 - 4.9
)
Sec.
Set keypad lock of continuous error operation
05 T
T
=
Continuous error times
:
3 ~ 9 (Times)
;
T
=
0 (Disable)
Door bell
06 PPP
PPP
=
000 ( Disable ) / PPP
=
001 ( Enable )
Master code settings
09 PPPPPPRRRRRR
PPPPPP= New master code
RRRRRR= Repeat the new master code
Suspend or delete user code
10 SSS EEE
SSS= starting user address ; EEE= ending user address
Recover user code
11 SSS EEE
SSS= starting user address ; EEE= ending user address
Add a User Code to the system
12 UUU PPPPPP
UUU
=
User address
PPPPPP
=
3 to 6 digits
Delete (Remove) a User Code
14 UUU
UUU
=
User address
Delete (Remove) all Users Codes
29 29
Factory Reset by its commands
If the master code is forgotten it can be restored to the factory default. Remove the AR-721KP from the mounting plate. Press and hold the reset switch
5 seconds. LED light green during 2.5 seconds and five beep sounds mean that master code have restored to the factory default 123456.
Delete (suspend) a (range of) User(s) Code from the system
Press
123456
(or Master Code)
→
10 SSS EEE
→
Done
(
A green light and beep means that the user code(s) was disabled.
)
[e.g.] Delete (suspend) User code
58
:
Access programming mode
→
10 058 058
→
Done
[e.g.] Delete (suspend) User code
1 to 10
:
Access programming mode
→
10 001 010
→
Done