3
3.3 DI Input V.S. Relay Output Connection setting of 701E Parameter
1. The DI.2 is exit button input of reader port 1 and the K1 is open door relay.
(1) Choose “DI 2” under the menu item.
(2) Click “K1”.
2. The DI.3 is exit button input of reader port 2 and the K2 is open door relay.
(1) Choose “DI 3” under the menu item.
(2) Click “K2”.
Note: Active second can be set only when the window is DI 1.
3.4 Weigand reader LED and Buzzer indicators
1. LED light green and one beep sound mean acknowledge, LED light green twice and two beep
sounds mean not acknowledge.
2. In anti-pass-back access mode, LED light green five times and five beep
sounds mean violates access function.
3. When access modes have entering user code, after flash card, LED light green four times and four
beep sounds mean that reader wait for being entered the 4-digit user code.