background image

V140707

   

Access Controller

Touch-panel Metal Housing / Illuminated Touch-panel

[e.g.] The anti-pass-back function of User Address 00154 has been enabled. After presenting the card to get in, the user doesn’t present the card to 

leave. When s/he tries to present the card to get in again, since the in-in sequence violates the anti-pass-back rule, s/he will be rejected. To solve this 

problem, you can reset it as follows. Enter program mode

 → 

26     00154     00154     2     

 → 

Reset

Enable/Disable auto-open time zone

Enter program mode

 → 

20     004       [004= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]

Enable/Disable auto open door without presenting card

Enter program mode

 → 

24     001       [001= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone]

[e.g.] Enable the anti-pass-back function of User Address from 00152 to 00684:

 

26     00152     00684     0

Enable card

Enter program mode

 → 

26     SSSSS     EEEEE     N      

[SSSSS= Starting User Address; EEEEE= Ending User Address; N=0(control)/ 1(Not control)/ 2(reset)]

Enable controller

Enter program mode

 → 

20     DDD       [128= Anti-pass-back(0=Disable; 1=Enable)/ 064=Entrance/Exit(0=Exit; 1=Entrance).]

         Enter program mode

 → 

20     128      (Please refer to function default value for details.)

[e.g.] Enable Anti-pass-back, and set to Exit door= (128 x 1) + (064 x 0) = 128

N: 2 sets of auto-open zone (N=0=1st set; N=1=2nd set)
HHMMhhmm=Staring time to ending time (e.g. 08301200=08:30 to 12:00)
7123456H= 7 days of a week (Sun/Mon/Tue/Wed/Thu/Fri/Sat) + Holiday (H= 0: disable; 1: enable);  Holidays can be set via 701Client software.

Set up auto-open time zone

Enter program mode

 → 

08     N     HHMMhhmm     7123456H

[e.g.] To set the second time zone as 9:30 AM to 4:20 PM, Monday, Wednesday and Friday: 08     1     09301620     01010100      

 → 

Done

M4/M8: Private PIN

Card or PIN:

 

Enter program mode

 → 

12     UUUUU     PPPP       [e.g. User Address: 00001 and pass code: 1234, input 12     00001     1234     ]

Card and PIN:

 

Enter program mode

 → 

13     UUUUU     PPPP       [e.g. User Address: 00001 and pass code: 1234, input 13     00001     1234     ]

M6: Public PIN
Card or PIN:

 

Enter program mode

 → 

15     PPPP       [Input 4-digit PIN, default value: 4321; PPPP=0000: cancel the function of simply inputting PIN to get access]

Card and PIN:

 

Enter program mode

 → 

17     PPPP       [Input 4-digit PIN, default value: 1234; PPPP=0000: access mode will be "Card Only"]

Enter program mode

 → 

00     NNN        [Node ID: 001~254; if the access controller is connected to AR-716E, its Node ID will be 001~016.]

Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to locations that 

need entry and exit control.

Door will remain open after the first flashing card. There are 2 time zones supported when Standalone, and 63 time zones when connected to AR-716E.

Enter program mode

 → 

28     064       [064= Double Door Control]

Controller with a reader to perform the "Double Door Control".

Enter program mode

 → 

04     N       [N=4/6/8]

D. Set up the password

E. Double Door Control (M4/M8)

F. Anti-pass-back (M4/M8)

G. Auto-Open Time Zone

B. Change the Node ID of Controller
C.Set up M4/M6/M8

H. Lift control

Enable

Enter program mode

 → 

24     002       [002= enable lift control]

[e.g.] User Address NO. 168, only to the 6th and the 20th floor:

         Enter program mode

 → 

21     00168     0     00100000     

 → 

21     00168     2     00001000

Multi floors

Enter program mode

 → 

21     UUUUU     S     FFFFFFFF

[UUUUU=User Address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0: Disable, F=1: Enable)

Single floor

[e.g.] User Address NO. 45, allowed to access the 24th floor:

 

27     00045     24

Enter program mode

 → 

27     UUUUU     FF

UUUU=User Address  FF=Floor number (01~32 floor)

Connect with 

AR-401RO16B

 to control access floors of users.

Set

Floor/ Stop

F

8

16

24

32

0

1

2

3

F

6

14

22

30

F

7

15

23

31

F

5

13

21

29

F

4

12

20

28

F

3

11

19

27

F

2

10

18

26

F

1

9

17

25

Please refer to below floor chart

Master Code modification

Enter program mode

 → 

09     PPPPPPRRRRRR         [Input the 6-digit new master code twice.]

[e.g.] Set the Master code to be 876112, input  

   

123456

     → 

09     876112876112

Enter the program mode

Input      123456      or      PPPPPP
[e.g.] The Default Value= 123456, if the Master Code is already changed= 876112, input  

   

876112

     → 

program mode entered

Exit the program mode

Input

Operation process

A. Enter / Exit Program Mode

Содержание AR-331

Страница 1: ...H AR 725 X 1 Product 1 Product 1 Product 1 Product 1 Products 1 Products 1 Products 3 User Guide 2 Optional 2 User Guide 2 User Guide 2 User Guide 2 User Guide 2 User Guide 4 Terminal Cables 3 Terminal Cables 3 Terminal Cables 3 Terminal Cables 3 Terminal Cables 3 Terminal Cables 5 Tools 4 Tools 4 Tools 4 Tools 4 Tools 4 Tools 2 Tools 5 Water proof Strip Parts Description Button Head Pozidriv Tapp...

Страница 2: ...the body and attach the body to the mounting plate Assemble the covers with the Allen key and screws accessories supplied Turn on the power and LED will light and beep will sound Pull the cables from the square access hole of the mounting plate C Use a screwdriver to screw the metal plate C onto the wall Take off the plastic mounting plate B from the body A and pull the cables through the access h...

Страница 3: ... Wire Application Exit Switch Networking Module Networking Module Alarm Relay Door contact Beeper Tamper Switch Lock Relay Power Pin 1 2 3 4 5 6 7 8 Pin 1 2 3 4 6 7 8 9 10 11 12 13 14 15 5 Color Blue White Purple White White Orange Purple Gray Thick Red Thick Black Color Thick Black Thick Red Purple Thick Green Thick Blue Yellow White Orange White Gray Orange Brown Yellow Pink Thin Blue Thin Green...

Страница 4: ...ing Illuminated Touch panel Strengthen security with AR 721RB Connect to Access Control for Connect to arming tools for Connect to Reader Alarm Alarm Tamper Alarm Controller Reader Controller Controller AR 716E Controller Controller Controller Controller Controller Converter Node ID 001 Node ID 254 Door Contact Door Contact Relay Outpot Module Relay Outpot Module AlarmRelay TamperRelay POWER 12VDC...

Страница 5: ...ress NO 101 NO 120 Enter program mode 19 00101 00120 Close Tag into RF Area only use the tag NO 62312 OK Tag Information 125kHz For Mifare tags the separator between Site Code Card Code is comma SITE CODE CARD CODE SITE CODE CARD CODE M6 In this mode User Address Card Code If you want to program system on AR 331 H S directly please order WG keyboard then install it according to the following patte...

Страница 6: ... Enter program mode 15 PPPP Input 4 digit PIN default value 4321 PPPP 0000 cancel the function of simply inputting PIN to get access Card and PIN Enter program mode 17 PPPP Input 4 digit PIN default value 1234 PPPP 0000 access mode will be Card Only Enter program mode 00 NNN Node ID 001 254 if the access controller is connected to AR 716E its Node ID will be 001 016 Usually anti pass back is commo...

Страница 7: ...larm by pressing RTE Button or Closing the Door Doorbell 0 Disable 0 Alarm Output 0 None 0 Disable Networking Standalone Networking Standalone Networking Standalone Networking Standalone 001 002 064 128 1 Enable 1 Lift Control 1 Yes 1 Enable Function Selection Value Application Auto Open without Presenting in Auto open Time Zone Lift Control Duress Function Stop Alarm by pressing RTE Button or Clo...

Страница 8: ...ng mode 001 600 1 600 sec TTT the buffer time before the alarm is activated 001 600 1 600 sec SSSSS EEEEE 00000 01023 00000 03000 for AR 725H SSSSS Starting User Address EEEEE Ending User Address N 0 1st time zone 1 2nd time zone HHMM Starting time hhmm ending time i e 08301600 08 30 to 16 00 7123456H 7 days of week Sun Mon Tue Wed Thu Fri Sat Holiday H 0 disable 1 enable Holidays can be set by 70...

Отзывы: