9
Hydraulics
Note that there can be variations in the configuration of the hydraulic power unit and the control
panel. In some cases, they are separate.
Contact Southworth Customer Service for further
assistance.
9.1
Hydraulic Fluid
This machine is supplied with Phillips 66 Powerflow NZ Hydraulic Fluid.
Do not substitute! Though Phillips 66 Powerflow NZ Hydraulic Oil is compatible
with most oils containing Zinc, mixing will result in poor machine performance,
could damage hydraulic components, and will lessen the environmental benefits
gained by using Phillips Powerflow NZ Hydraulic Oil.
9.2
Typical Hydraulic Schematic
DOWN SOLENOID VALVE
LOAD CHECK VALVE
SYSTEM RELIEF
PUMP
SINGLE EXCESS FLOW PROTECTOR
ADJUSTABLE PRESSURE COMPENSATED
DOWN SPEED FLOW CONTROL
VENT LINE TO RESERVOIR
2 OR MORE CYLINDERS CONNECTED WITH STEEL MECHANICAL TUBING
SUCTION SCREEN
RESERVOIR
THE POINT IN THE 90DEG BEND NEXT TO RESERVOIR IS FIXED.
REVISIONS
REV.
ZONE
DESCRIPTION
DATE
REVISED BY
ECN #
A
REDRAWN IN SOLIDWORKS. EXCESS FLOW PROTECTOR WAS BACKWARDS. 12/23/2020
SMP
064326
2
1
1
2
A
B
B
A
16
A
FRACTIONS 1/
.XXX .005
.XX .01
ANGLES: .5
MODEL
SMP
DATE
1:1
DR
SHEET 1 OF 1
063Z8
CAGE CODE
WT
USE OF PROPRIETARY INFORMATION
LIMITED TO WRITTEN AGREEMENT
TITLE
REV
60050722
A
0.0 LB
60073481/60064844
DOCKLIFT
HY PLUMBING SCHEMATIC
3RD ANGLE
PROJECTION
P.O. Box 1380 Portland Maine 04104-1380
SIZE
UNLESS OTHERWISE
SPECIFIED.
DIMENSIONS ARE
IN INCHES
-
12/23/2020
SCALE
DWG NO.
REF
SOUTHWORTH PRODUCTS CORP.
SHEET 1 OF 1
60050722
DWG NO.
v.14
THIS DRAWING MUST BE AT REVISION: 'A'
9.3
Hose Specifications
Minimum operating pressure rating 3,050 psi, 12,200 psi burst pressure.
Pressure hose is optional. Units supplied with 25 feet of vent line and
the hydraulic power unit vent line connection elbow if pressure hose not
purchased. Otherwise, the vent line comes in the same length as the
pressure hose.
TO VENT LINE
CONNECTION ON LIFT
VENT LINE
ELBOW FOR
RESERVOIR