background image

For technical assistance, please call 1-800-780-4324 x 20311 

Manufactured by Southwire Company, LLC, 4525 140th Avenue North, Suite 900, Clearwater, Florida 33762

© 2017 Southwire Company, LLC. All rights reserved.              * Trademark of Southwire Company, LLC. Registered in the United States.

506-00012B

TROUBLESHOOTING GUIDE    

Model 67030 

30A Surge Guard* Portable RV 

Power Protection Device with LCD Display

ERROR MESSAGE

DESCRIPTION

REPLACE

SURGE

Surge Expended  

The Surge Guard device's built-in surge pro-

tection has been sacrificed to protect your equipment and is no longer 

functioning properly. The unit is recommended to be replaced. 

OPEN

GROUND

Open Ground 

 Disconnect unit. Use a voltmeter to check the 

ground and neutral. Voltage should read -0-. If not, finding another 

power source is recommended.

REVERSE

POLARITY

Any Line Wired to Neutral 

 Use a voltmeter to check for voltage 

on ground or neutral. Voltage should read -0-. If not, finding another 

power source is recommended.

L1 High

118V 42A

High Voltage

 Voltage is over recommended operation, check with 

power source to lower voltage to >132V.

L1 Low

118V 42A

Low Voltage

 Voltage is under recommended operation, check with 

power source to raise voltage to <102V.

CUR

HIGH

Current High 

Current exceeds the recommended operation. Check 

connection with voltmeter and verify voltages are within normal opera-

tion. If not, it is recommended to find another power source.