background image

13

Specifications

NOTE:

 Accuracy is stated at 65°F to 83°F (18°C to 28°C) and less than 70% RH.

Input Impedance: 10M

Ω

.      Maximum Input: 1000V DC or 1000V AC rms.

Function                            Range           Resolution       Accuracy (% of reading)

DC Voltage
(Auto-ranging)

400.0mV
4.000V
40.00V
400.0V
1000V

0.1mV
1mV
10mV
100mV
1V

± 0.5% of rdg ± 3 digits

± 1% of rdg ± 3 digits

Input Impedance: 10M

Ω

.

AC Response: 50Hz to 400Hz

Maximum Input: 1000V DC or 1000V AC rms.

AC Voltage 
(Auto-ranging)

400.0mV
4.000V
40.00V
400.0V
1000V

0.1mV
1mV
10mV
100mV
1V

± 1.0 % of rdg ± 30 digits

± 1.2% of rdg ± 5 digits

Overload Protection: FF500mA / 1000V and F10A / 1000V Fuse

AC Response: 50Hz to 400Hz

Maximum Input: 4000uA AC rms. on uA, 400mA AC rms. on mA, 10A AC rms. on 10A range

AC Current 
(Auto-ranging)

400.0uA
4000uA
40.00mA
400.0mA
10A

0.1uA
1uA
10uA
100uA
10mA

± 1.2% of rdg ± 5 digits

± 2.5% of rdg ± 5 digits

Overload Protection: FF500mA / 1000V and F10A / 1000V Fuse

DC Current
(Auto-ranging)

400.0uA
4000uA
40.00mA
400.0mA
10A

0.1uA
1uA
10uA
100uA
10mA

± 1.0% of rdg ± 5 digits

± 2.5% of rdg ± 3 digits

Maximum Input: 4000uA DC on uA range, 400mA DC on mA range, 10A DC on 10A range

14

Specifications

Input Protection: 1000V DC or 1000V AC rms.

Function                            Range           Resolution       Accuracy (% of reading)

Resistance 

Ω

(Auto-ranging)

400.0

Ω

4.000k

Ω

40.00k

Ω

400.0k

Ω

4.000M

Ω

40.00M

Ω

0.1

Ω

1

Ω

10

Ω

100

Ω

1k

Ω

10k

Ω

± 0.8% of rdg ± 5 digits

± 0.8% of rdg ± 2 digits

± 2.5% of rdg ± 8digits

Sensitivity:  >3V RMS while  

1MHz ;

Sensitivity:  >8V RMS while >1MHz ;

Input Protection: 1000V DC or 1000V AC rms. 

Frequency
(Auto-ranging)

4.000Hz
40.00Hz
400.0Hz
4.000KHz
40.00kHz
400.0kHz
5.00MHz

0.001Hz
0.01Hz
0.1Hz
1 Hz
10Hz
100Hz
1kHz

± 1.0% of rdg ± 3 dgts

± 1.2% of rdg ± 4 dgts

Input Protection: 1000V DC or 1000V AC rms.

Capacitance
(Auto-ranging)

40.00nF
400.0nF
4.000uF
40.00uF
100.0uF

10pF
0.1nF
1nF
10nF
0.1uF

± 5.0% of rdg ± 7 dgts

± 3.0% of rdg ± 5 dgts

± 5.0% of rdg ± 7 dgts

IPulse width: >100us, <100ms; 

Frequency width: 5Hz – 150kHz

Sensitivity: >8V RMS 

Overload protection: 1000V DC or AC rms.

Duty Cycle

0.1%~99.9%

0.1%

± 1.2% of rdg ± 2 dgts

Содержание 11060S

Страница 1: ...Contents Made in China Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 2014 Southwire Company LLC All rights reserved southwiretools com 1 855 SW T00LS Toll Free...

Страница 2: ...be sure to secure the back cover panel and battery compartment door rmly to maintain the waterproof and dust proof integrity of the meter Loose or overtightened screws or an improperly seated o ring...

Страница 3: ...ary distribution panels Overhead or underground lines to detached buildings Incoming service entrance from utility Outdoor pumps WARNING Operation is limited to CAT II applications when the insulated...

Страница 4: ...red value 4 Press the REL button to return to normal operation HZ Button The HZ button is used to select frequency or duty cycle in when in the frequency voltage or current function When in the voltag...

Страница 5: ...urrent AC or DC will appear on the LCD display AC and DC Current Measurements Observe all safety precautions when working on live voltages WARNING Observe all safety precautions when working on live v...

Страница 6: ...ible tone will sound If the circuit is above 400 the LCD display will indicate OL The resistance will be shown on the LCD display if it is below 400 Wire 10 WARNING Operation 1 Set the rotary function...

Страница 7: ...h a fresh 9V battery 5 Install battery door and tighten screws WARNING TO AVOID ELECTRICAL SHOCK REMOVE ALL INPUTS BEFORE OPENING THE CASE TO PREVENT FIRE INSTALL FUSE WITH AMP VOLT RATING SHOWN 9V BA...

Страница 8: ...Fuse DC Current Auto ranging 400 0uA 4000uA 40 00mA 400 0mA 10A 0 1uA 1uA 10uA 100uA 10mA 1 0 of rdg 5 digits 2 5 of rdg 3 digits Maximum Input 4000uA DC on uA range 400mA DC on mA range 10A DC on 10A...

Страница 9: ...tenance or repair operation outside of specifications or abnormal handling of the product Southwire s sole liability and the purchaser s exclusive remedy for any breach of this warranty is expressly l...

Отзывы: