14 of 38
Copyright 2015 by Southern Pride Distributing, LLC Volume 1
GAS CONNECTION INSTRUCTIONS
For smokers equipped with casters, the installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 CSA 6.16, and a quick-disconnect device
that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 CSA 6.9.
Adequate means must be provided to limit the movement of the appliance without depending on the connector
and the quick-disconnect device or its associated piping to limit the appliance movement.
The restraining device may be attached using the mounting hole provided on the rear of the smoker. Refer to
page 6 to locate the mounting hole and page 15 for the installation instructions.
WARNING: Operator should be aware that a restraint device is in place on smokers equipped with
casters. If disconnection of the restraint is necessary, it must be reconnected after the appliance has been
returned to its originally installed position.
IMPORTANT ITEMS TO CHECK BEFORE FIRING THE BURNER
1. Gas
line
MUST
be installed by a qualified technician and in accordance with this Manual.
2. Gas
line
MUST
include an easily accessible manual shutoff valve, drip leg, and pressure gauge port.
3. Gas pipe size
MUST
be in accordance with the Pipe Capacity Chart in this Manual (pages 12 and 13).
4. Gas
line
MUST
be tested for leaks under pressure.
5. Gas
line
MUST
be purged to remove any air in the system.
6. Gas line pressure
MUST
be checked and
MUST NOT
exceed the maximum pressure specified in the
Burner Specifications on page 16.
7. Burner orifice
MUST
correlate with the type of gas being supplied, as specified in the Burner Specifica-
tions on page 16
.
WARNING:
Improper gas hookup will void the warranty and could result in a hazardous condition.