Changing the User Code

The unit is shipped with a default user code of 1234, but can be changed
to a 3-7 digit number. To change the user code:

1.

Press the 9·0 button for approximately 3 seconds. Keypad lights
will flash twice then stay on.

2.

Enter the current user code. When entering the last digit of the
current user code, hold the button for approximately 2 seconds.
Keypad lights will flash once then stay on.

3.

Enter the new user code. When entering the last digit of the new
user code, hold the button for approximately 2 seconds. Keypad
lights will flash once then stay on.

4.

Repeat the new user code. When entering the last digit of the
new user code, hold the button for approximately 2 seconds.

5.

Keypad lights will flash once then turn off. The user code has
been successfully changed.

If the keypad lights turn off during Steps 1-4, then programming has been
timed out and the process needs to be repeated from Step 1.

NOTE:

Refer to “

Resetting the User Code

” section if the user code

is lost or forgotten.

Enrolling Transmitters and Setting LOCK/UNLOCK Pulse Duration

Enrolling additional transmitters or setting the LOCK/UNLOCK pulse
duration will require access to the programming switches on the EA-R02-
202 receiver’s circuit board. To access the switches, remove the switch
access tab by sliding the tab away from the receiver unit as shown below.

Two switches will be visible thru the tab window (default positions shown):

Switch1 – Used to enroll transmitters. Default setting = “OFF”
position.

Switch 2 – Used to set LOCK and UNLOCK pulse duration:

Switch2 Setting

Duration

ON (default)

250ms (default)

OFF

10sec

NOTE:

The switch access tab must always be re-installed when done

changing the settings.

Enrolling Transmitters

The EA-R03 kit is shipped with one EA-R02-202 receiver and one pre-
enrolled EA-R03-103 keypad transmitter. This transmitter is ready to use
with the receiver.

Up to four compatible transmitters can be enrolled with the receiver. To
enroll a transmitter:

1.

Verify receiver has 12VDC power supply.

2.

Move Switch1 from OFF to ON position, as shown below. The
auxiliary output will turn on.

3.

Within six seconds of moving Switch1 to the ON position, enter
the current user code of the new keypad (e.g. 1234), then press
the 1·2 button. The auxiliary output will pulse to indicate the
transmitter has been enrolled.

4.

If additional keypads are to be enrolled, enter the current user
code of the new keypad (e.g. 1234), then press the 1·2 button
within three seconds of enrolling the previous transmitter. The
auxiliary output will pulse twice to indicate transmitter #2 has
been enrolled, three times to indicate transmitter #3 has been
enrolled, and four times to indicate transmitter #4 has been
enrolled.

Содержание EA-R03

Страница 1: ...mA maximum no attached devices Receiver Operating Current 100mA maximum no attached devices Receiver Outputs three Form C relays rated 15A at 14VDC Receiver Operating Temp 20 to 80 C Operating Range up to 60 feet 18 meters open air Operating Frequency 433 92MHz Coding Type Fixed Code 24 Bit Transmitter Power Type CR2032 3VDC battery Normal Use The keypad transmitter can be used to lock and unlock ...

Страница 2: ...rogramming switches on the EA R02 202 receiver s circuit board To access the switches remove the switch access tab by sliding the tab away from the receiver unit as shown below Two switches will be visible thru the tab window default positions shown Switch1 Used to enroll transmitters Default setting OFF position Switch 2 Used to set LOCK and UNLOCK pulse duration Switch2 Setting Duration ON defau...

Страница 3: ...s shown in the following location The production date code is unique to each keypad Each production date code corresponds to a unique supervisor code that is required to reset the user code To obtain the supervisor code contact Southco and provide the production date code for your keypad Once the supervisor code is provided perform the following to reset the user code to 1234 1 Press the 9 0 butto...

Страница 4: ...ment This equipment complies with all the requirements of DIRECTIVE 1999 5 EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL of March 9 1999 on radio equipment and telecommunication terminal Equipment and the mutual recognition of their conformity R TTE The R TTE Directive repeals and replaces in the directive 98 13 EEC Telecommunications Terminal Equipment and Satellite Earth Station Equipment as of ...

Отзывы: