![Southco EA-KC2-201 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/southco/ea-kc2-201/ea-kc2-201_instructions-for-programming_1337051005.webp)
Sdfsfsdfsfdsafsafsdfsff
EA-KC2-201 Membrane Keypad Controller
Instructions for Programming EA-KC2-201
J-EA-KC2-201-M_revB visit
www.southco.com
for latest version of this document Page 3 of 3
The blue Status LED will flash indicating that programming is complete.
Programming the same user access code to both latch outputs will allow
that user access code to open both latches simultaneously.
If the user memory is full or an invalid key is pressed (‘*’, ‘Lock’), the red
status LED will flash. If the code entered is already stored in memory, the
blue status LED will flash.
6 * : Program Door Release Time
The length of time the latch(es) are released can be programmed from 1
second to 100 minutes and 39 seconds. To change from the default of ten
seconds:
1.
Press
the ‘*’ key, then enter the 4 digit supervisor code followed
by the ‘*’ key. The blue status LED will light.
2.
Press the ‘6’ key, followed by the ‘*’ key.
3.
Enter the desired amount of time in the format ‘MMSS’ where
MM is the number of minutes and SS is the number of seconds.
The blue Status LED will flash indicating programming is complete. If an
invalid key is
pressed (‘*’, ‘Lock’), the red status LED will flash.
NOTE:
The programmed door release time must be greater than the
connected latch’s cycle time.
7 * : Program New Supervisor Code
The supervisor code can be changed from its default setting (7183) to a
different 4 digit code. To change the supervisor code:
1.
Press
the ‘*’ key, then enter the 4 digit supervisor code followed
by the ‘*’ key. The blue status LED will light.
2.
Press the ‘7’ key, followed by the ‘*’ key.
3.
Enter the new four digit supervisor code.
The blue Status LED will flash indicating that programming is complete. If
an invalid key is pressed (‘*’, ‘Lock’), the red status LED will flash.
WARNING: The supervisor code cannot be recovered if lost or
forgotten. Store the supervisor code in a secure place.
8 * : Latch Power Mode
Enabling this mode will provide constant power to both latches. This is
required if the connected latch has a feature that requires constant power
(e.g. Sou
thco’s H3-EM Electronic Locking Swinghandle’s status LED).
Latch Power Mode is disabled by default. To enable this mode:
1.
Press
the ‘*’ key, then enter the 4 digit supervisor code followed
by the ‘*’ key. The blue status LED will light.
2.
Press the ‘8’ key, followed by the ‘*’ key.
The blue Status LED will flash indicating that programming is complete. If
an invalid key is pressed (‘*’, ‘Lock’), the red status LED will flash.
This mode can be toggled on and off by entering this programming code
again.
NOTE:
Latch Power Mode will be disabled if power is removed from
the controller.
Latch Connector Pin Assignment
The controller’s latch output connectors provide a power supply and
command output for the electromechanical latches. These will be the
same voltage level as the controller’s power supply voltage (12 to 24VDC).
The controller’s power supply input must not exceed the electrical
ratings of the latch(es).
The figure and table below show the pinout of the latch output connectors.
Pin #
Description
Note
1
V
GND
ground
2
V
SUPPLY
power supply output to latch
3
V
GND
ground
4
Control Signal
door release command output
5
N/C
no connection
6
N/C
no connection
CAUTION:
A keypad that has been programmed is non-returnable.
Please use caution in programming functions so as not to render the
keypad unusable.
PIN 1
PIN 2 PIN 4
PIN 3
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
Industry Canada Compliance Statement
This Class B digital apparatus complies with Canadian ICES-003.
CET appareil numérique de la classe B est conforme á la norme NMB-003 du Canada.
For technical support of this product contact:
or visit
www.southco.com
.