                                                          Instructions for Programming EA-KC2-201

 

 

 

J-EA-KC2-201-M_revB                                       visit 

www.southco.com

 for latest version of this document                                                Page 3 of 3 

 

 
 
 
The blue Status LED will flash indicating that programming is complete.  
Programming the same user access code to both latch outputs will allow 
that user access code to open both latches simultaneously. 
 
If the user memory is full or an invalid key is pressed (‘*’, ‘Lock’), the red 
status LED will flash.  If the code entered is already stored in memory, the 
blue status LED will flash.    

 

 

6 * : Program Door Release Time  

  

The length of time the latch(es) are released can be programmed from 1 
second to 100 minutes and 39 seconds.  To change from the default of ten 
seconds: 
 

1. 

Press 

the ‘*’ key, then enter the 4 digit supervisor code followed 

by the ‘*’ key.  The blue status LED will light. 

2. 

Press the ‘6’ key, followed by the ‘*’ key. 

3. 

Enter the desired amount of time in the format ‘MMSS’ where    
MM is the number of minutes and SS is the number of seconds.   

 
The blue Status LED will flash indicating programming is complete.  If an 
invalid key is 

pressed (‘*’, ‘Lock’), the red status LED will flash.  

 

 

NOTE:   

The programmed door release time must be greater than the 

connected latch’s cycle time.   
 
 

7 * : Program New Supervisor Code  

 
The supervisor code can be changed from its default setting (7183) to a 
different 4 digit code.  To change the supervisor code: 
   

1. 

Press 

the ‘*’ key, then enter the 4 digit supervisor code followed 

by the ‘*’ key.  The blue status LED will light. 

2. 

Press the ‘7’ key, followed by the ‘*’ key.        

3. 

Enter the new four digit supervisor code. 
 

The blue Status LED will flash indicating that programming is complete.  If 
an invalid key is pressed (‘*’, ‘Lock’), the red status LED will flash.  
 

 

 

WARNING:  The supervisor code cannot be recovered if lost or 

forgotten.  Store the supervisor code in a secure place. 

 
 
8 * : Latch Power Mode

  

 
Enabling this mode will provide constant power to both latches.  This is 
required if the connected latch has a feature that requires constant power  
(e.g. Sou

thco’s H3-EM Electronic Locking Swinghandle’s status LED). 

 

 
 
 
Latch Power Mode is disabled by default.  To enable this mode: 
 

1. 

Press 

the ‘*’ key, then enter the 4 digit supervisor code followed 

by the ‘*’ key.  The blue status LED will light. 

2. 

Press the ‘8’ key, followed by the ‘*’ key.        
 

The blue Status LED will flash indicating that programming is complete.  If 
an invalid key is pressed (‘*’, ‘Lock’), the red status LED will flash.  
 
This mode can be toggled on and off by entering this programming code 
again. 
 

 

NOTE:  

Latch Power Mode will be disabled if power is removed from 

the controller. 

 

 
 
Latch Connector Pin Assignment 
 

The controller’s latch output connectors provide a power supply and 
command output for the electromechanical latches.  These will be the 
same voltage level as the controller’s power supply voltage (12 to 24VDC).  

The controller’s power supply input must not exceed the electrical 
ratings of the latch(es). 

 
The figure and table below show the pinout of the latch output connectors. 

 

 

 

Pin # 

Description 

Note 

V

GND

 

ground 

V

SUPPLY

 

power supply output to latch 

V

GND

 

ground 

Control Signal 

door release command output 

N/C 

no connection 

N/C 

no connection 

 
 

 

CAUTION:

  A keypad that has been programmed is non-returnable.  

Please use caution in programming functions so as not to render the 
keypad unusable. 
 

 

PIN 1 

PIN 2  PIN 4 

PIN 3 

FCC Compliance Statement 

 
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may 
cause harmful interference to radio communications.  Operation of this equipment in a residential area is likely to cause harmful interference in 
which case the user will be required to correct the interference at his own expense. 
 

Industry Canada Compliance Statement 

 
This Class B digital apparatus complies with Canadian ICES-003. 
CET appareil numérique de la classe B est conforme á la norme NMB-003 du Canada. 
 
 
For technical support of this product contact: 

[email protected]

 or visit 

www.southco.com

Отзывы: