NOTICE

Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the 

warranty.
Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s instructions.

Canopies are set over ranges, ovens, etc., for ventilation purposes. It is recommended that a canopy extend 6” past the 

appliance and the bottom edge be located 78” above the floor. Filters should be installed at an angle of 45° or more from 

the horizontal. This position prevents dripping grease and facilitates collecting the run-off grease in a drip pan, usually 

installed with a filter.
A strong exhaust fan tends to create a vacuum in the room and may interfere with burner performance or may extinguish 

pilot flames. Fresh air openings approximately equal to the fan area will relieve such a vacuum.
The exhaust fan should be installed at least 2” above the vent opening at the top of the broiler.
If the broiler is connected directly to an outside flue, a CSA design-certified down draft diverter must be installed.

S

PECIFICATIONS

NOTICE

Due to the variety of problems encountered by outside weather conditions, venting by canopies or wall fans is 

preferred over any type of direct venting.

If the unit is connected directly to an outside flue, a CSA design certified down draft diverter must be installed.

In case of unsatisfactory performance on any appliance, check the appliance with the exhaust fan turned OFF. Do this 

only long enough to check whether doing so corrects any problems with equipment performance. Then turn the exhaust 

fan back on and let it run to remove any exhaust that may have accumulated during the test.

G

AS 

S

UPPLY

The broiler is design-certified for operation on natural gas or propane. The broiler is shipped configured and adjusted for 

the type of gas specified by the purchaser, which is indicated on the serial plate (see Figure 1). Connect the broiler ONLY 

to the type of gas for which it is configured and adjusted.
Sectional range (field mount), wall mount, or countertop broilers will be supplied with the appropriate regulator and will 

require field piping.  Restaurant range mounted broilers will connect to the existing regulator on the restaurant range oven 

base.

A model that mounts on the flue riser of a range will have a 3/8” rear gas connection (with a 3/8” male NPT connector) 

extending through the rear of the flue riser (see Figure 2 on page 7).

Wall-mount and countertop models will have a 3/8” rear gas connection (with a 3/8” male NPT connector). The gas 

connection can extend directly out the rear of the broiler (near the bottom right-rear corner).
Minimum supply pressure is 7” W.C. for natural gas, 11” W.C. for propane. If using a flexible-hose gas connection, the 

I.D. of the hose must not be smaller than the connector on the broiler, and must comply with ANSI Z21.69. Provide an 

adequate means of restraint to prevent undue strain on the gas connection.
If applicable, the vent line from the gas appliance pressure regulator must be installed to the outdoors in accordance with 

local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation 

Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for 

satisfactory performance. A 1/8” pressure tap is located on the manifold to measure the manifold pressure.
Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the broiler.
All pipe joints and connections must be tested thoroughly for gas leaks. Use only soapy water for testing on all gases. 

NEVER use an open flame to check for gas leaks. All connections must be checked for leaks after the range has been put 

into operation. Test pressure should not exceed 14” W.C. (3.47 kPa).

Содержание P32-NFR

Страница 1: ...__ Serial ___________________________ Date Purchased _____________________ 1100 Old Honeycutt Road Fuquay Varina North Carolina 27526 USA www southbendnc com WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment Owner s...

Страница 2: ... in a prominent location detailed instructions to be followed in the event the operator smells gas Obtain the instructions from the local gas supplier WARNING EXPLOSION AND ASPHYXIATION HAZARD In the event a gas odor is detected shut down equipment at the main gas shut off valve and immediately call the emergency phone number of your gas supplier Improper ventilation can result in headaches drowsi...

Страница 3: ...nstallation 6 Operation 12 Cleaning 15 Troubleshooting 17 Read these instructions carefully before attempting installation Installation and initial startup should be performed by a qualified installer Unless the installation instructions for this product are followed by a qualified service technician a person experienced in and knowledgeable with the installation of commercial gas an or electric c...

Страница 4: ...IFICATIONS CLEARANCES WARNING Improper ventilation can result in personal injury or death Ventilation which fails to properly remove flue products can cause headaches drowsiness nausea or could result in death All units must be installed in such a manner that the flow of combustion and ventilation air is not obstructed Provisions for adequate air supply must be provided Do not obstruct the front o...

Страница 5: ...justed for the type of gas specified by the purchaser which is indicated on the serial plate see Figure 1 Connect the broiler ONLY to the type of gas for which it is configured and adjusted Sectional range field mount wall mount or countertop broilers will be supplied with the appropriate regulator and will require field piping Restaurant range mounted broilers will connect to the existing regulat...

Страница 6: ...oncealed a claim must be made with the delivering carrier Apparent damage or loss must be noted on the freight bill at the time of delivery The freight bill must then be signed by the carrier representative Driver If the bill is not signed the carrier may refuse the claim The carrier can supply the necessary forms A request for inspection must be made to the carrier within 15 days if there is conc...

Страница 7: ... front edge of the flue riser If necessary move the broiler left or right so that the holes in the top of the broiler hook line up with the holes in the top of the flue riser then secure the broiler hook to the flue riser using three 10 self tapping screws provided 3 Secure the bottom of the broiler to the flue riser with the four 1 4 self tapping screws provided The holes are accessible from the ...

Страница 8: ...TEP 2B MOUNT ON WALL 3 It may be more convenient to prepare the gas supply line before the broiler is mounted on the wall bracket If so install the supply line and connector now but do not yet attach it to the broiler 4 Lift the broiler using two people is recommended and hook the broiler hook over the top of the front of the wall bracket If necessary move the broiler left or right so that the hol...

Страница 9: ...require field piping Restaurant range mounted broilers will connect to the existing regulator on the restaurant range oven base Broilers mounted on the flue riser of a range will have a 3 8 rear gas connection with a 3 8 male NPT connector extending through the rear of the flue riser see Figure 3 For wall mount and countertop models the gas connection 3 8 male NPT extends directly out the rear of ...

Страница 10: ...s supply to the inlet at right rear corner using the external regulator shipped with the unit 4 For flue riser mounted installation use the supplied regulator Connect gas supply from broiler which extends through a hole on the rear of the riser to the rear tailpipe of the oven base 5 Turn on the gas and check for leaks using soapy water STEP 4 INSTALL SLOPED ENCLOSURE OPTIONAL ACCESSORY To install...

Страница 11: ...ect flame appearance and height at both the HIGH and LOW settings When the burners ignite a blue haze type flame will cover the surface of the ceramics but will gradually disappear within two minutes When the burner control is set to HIGH the ceramics should glow red and the flame on the surface of the ceramics should be barely visible with little or no blue haze When the burner control is set to ...

Страница 12: ...s that provide better quality products in about one half the usual broiling time and with less gas input than ordinary broilers Very little energy is wasted in heating secondary surfaces which is necessary for conventional type broilers Since the surface of the ceramic tiles becomes red hot in less than one half minute the broiler is ready to start broiling with a very short preheat time thereby s...

Страница 13: ...ht the constant burning pilots located near the front of the broiler burners unless the pilots are already lit See page 10 for directions on how to light the pilots 2 If necessary pull out and empty the bottom grease drawer Always keep the drip trays in place while broiling Without it in place excessive air will be pulled past the burners reducing the cooking temperature and efficiency 3 Infrared ...

Страница 14: ...the control valves on the front of the broiler to OFF 2 Turn on the gas supply to the broiler if not already on 3 Light the pilots To light the pilots on a broiler WITH the flame failure option do the following 1 Turn the control valves on the front of the broiler to OFF 2 Turn on the gas supply to the broiler if not already on 3 Turn one of the burner control knobs to the PILOT position and push ...

Страница 15: ...e the bottom grease drawer and clean it 7 Clean all parts of the raising and lowering frame 8 Lubricate bearings with cooking oil helps to extend the life of the bearings 9 Reassemble broiling rack mechanism 10 Check that nothing has been placed on top of the broiler which will block the escape of combustion exhaust 11 Check that the air intake openings on the rear of the broiler are not obstructe...

Страница 16: ...ads or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further spoil the appearance of the finish NEVER USE A WIRE BRUSH STEEL SCOURING PADS EXCEPT STAINLESS SCRAPER FILE OR OTHER STEEL TOOLS Surfaces which are marred collect dirt more rapidly and become more difficult to clean Marring also increases the possibility of corrosive attack Refi...

Страница 17: ...ms in operation at initial installation check type of gas and manifold pressure and compare with information listed on the serial plate TROUBLESHOOTING Problem Look for 1 Not enough heat Low pressure in gas supply Restriction in gas piping and or valves Misalignment of burner orifice tube Clogged burner orifice Incorrect burner orifice Too much heat Incorrect orifice Defective or incorrectly set p...

Страница 18: ...is manual for guidance ADJUSTMENT OF BROILER PILOTS The pilots are adjusted at the factory If later the pilots are over adjusted to the point where the flame is leaving its port or blowing off the result is an unstable condition in which the pilot may extinguish If necessary adjust the pilots using the following procedure 1 If necessary light the pilots 2 Locate the pilot adjustment screw which ad...

Страница 19: ...d 3 Turn the broiler control knob to HIGH and with the burners lit check the manifold pressure The pressure should be 4 W C for natural gas or 10 W C for propane gas 4 If necessary adjust the pressure by unscrewing the top of the pressure regulator use a screwdriver to expose the adjustment screw underneath Rotating the adjustment screw clockwise increases the manifold pressure 5 After the pressur...

Страница 20: ...INFRARED RADIANT COMPACT BROILER OWNER S MANUAL 1186527 REV 6 8 14 PAGE 20 OF 21 Notes ...

Страница 21: ...rts and occasional professional service may be necessary to extend the useful life of this appliance When service is needed contact a Southbend Authorized Service Agency or your dealer To avoid confusion always refer to the model number serial number and type of your appliance Southbend 1100 Old Honeycutt Road Fuquay Varina North Carolina 27526 USA www southbendnc com Platinum NFR Infrared Radiant...

Отзывы: