background image

1100 Old Honeycutt Road, Fuquay-Varina, NC 27526

(919) 762-1000  www.southbendnc.com

Models:

www.yatesgd.com  www.yatesgraphicdesign.com

 

 

460DD-3G

 

460AD-3G

  

 

460AA-3G

 

 

460DD-4G

 

460AD-4G

  

 

460AA-4G

INTENDED FOR COMMERCIAL USE ONLY.

NOT FOR HOUSEHOLD USE

.

Dimensions -in (mm)

Form 460-3G4G Rev 4 (04/07)

OPTIONS AND ACCESSORIES

NOTES:

1. Optional -Hot Plate in lieu of 2
open top burners at 12,000 BTU/
burner (24,000 BTU total NAT or LP)
2. Thermostat griddle control with 1
throttling-type thermostats.
Temperature range of 100° to 450°F
(add prefix T).

10” Flue Riser
3/4” quick disconnect with flexible hose complies with
ANSI Z 21.69 (specify 3ft, 4ft, 5ft)
Casters-all swivel-front with locks
Hot Top plates - each plate replaces 2 Open burner section

Various salamander & cheesemelter mounts
available. (Please refer to the price list)
Auxillary griddle plates
Extra Oven Racks
Cabinet Base

MISCELLANEOUS

UTILITY INFORMATION

- If using Flex-Hose, the I.D. should not be smaller than 3/4”

and must comply with ANSI Z 21.69

- If casters are used with flex hose, a restraining device should

be used to eliminate undue strain on the flex hose

- For installation on combustible floors (with 6” high legs) and

adjacent to combustible walls, allow 6” clearance.

- Install under vented hood
- Check local codes for fire, installation and sanitary regulations.

NOTICE:

Southbend has a policy of continuous product research and
improvement.  We reserve the right to change specifications

and product design without notice.  Such revisions do not
entitle the buyer to corresponding changes, improvements,

additions or replacements for previously purchased
equipment.

GAS:

- 460DD-3G/T Total BTU NAT: 286,000; LP: 264,000

- 460AD-3G/T Total BTU NAT: 273,000; LP: 254,000
- 460AA-3G/T Total BTU NAT: 260,000; LP: 244,000

- 460DD-4G/T Total BTU NAT: 236,000; LP: 220,000

- 460AD-4G/T Total BTU NAT: 223,000; LP: 210,000
- 460AA-4G/T Total BTU NAT: 210,000; LP: 200,000

- Required minimum inlet pressure

-  Natural gas 4” W.C.

-  Propane gas 10” W.C.

- Pressure regulator is supply with unit

- Required supply line size to the regulator is 3/4” NPT.

ELECTRICAL:

-  Standard -115/60/1 furnished with 6’ cord with 3-prong plug.

Total max amps 4.8

-  Optional -208/60/1, 50/60/1 or 3 phase. Supply must be wired  to

junction box with terminal block located at rear.  Total max amps
2.6

M

ODELS

E

XTERIOR

C

OOK

T

OP

D

OOR

O

PENING

O

VEN

B

OTTOM

3/4"

 

G

AS 

C

ONN

.

E

LECTRIC

W

IDTH

A

D

EPTH

B

C

D

E

F

G

H

J

K

L

M

N

O

P

Q

R

460DD-3G/3T
460DD-4G/4T

60.75"

(1543)

34.00"

(864)

29.75"

(756)

31.00"

(787)

12.00"

(305)

2.75"

(70)

59.50"

(1511)

22.50"

(572)

31.00"

(787)

6.00"

(152)

37.00"

(940)

15.50"

(394)

13.00"

(330)

3.25"

(83)

30.25"

(768)

-

-

460AA-3G/3T
460AA-4G/4T

60.75"

(1543)

44.50"

(1130)

29.75"

(756)

31.00"

(787)

12.00"

(305)

2.75"

(70)

59.50"

(1511)

22.50"

(572)

31.00"

(787)

6.00"

(152)

37.00"

(940)

15.50"

(394)

13.00"

(330)

3.25"

(83)

30.25"

(768)

24.00"

(610)

6.00"

(152)

M

OD E L S

B

U R N E R S 

(B TU

 

E

A C H 

NAT/LP )

O

V E N  

I

N TE R IO R

C

R ATE  

S

IZE

C

U B IC

V

O LU M E

C

R A TE D

W

EIG H T

G

RID D LE

O

P E N

O

V E N

W

ID TH

D

E P TH

H

E IGH T

W

ID TH

D

E P TH

H

E IG H T

460DD-3G /3T

4@ (16K / 16K )

4@ (33K / 30K )

2@ (45K /40K )

26. 00"

(660)

26.5 0"

(673)

14.00"

(356)

67.0 0"

(1118)

45. 50"

(1702)

75.00"

(1905)

132.3 c u. ft

3.75 c u .m .

860 lb s .

390.1k g .

460DD-4G /4T

5@ (16K / 16K )

2@ (33K / 30K )

460A A -3G /3T

4@ (16K / 16K )

4@ (33K / 30K )

2@ (32K /30K )

26. 00"

(660)

24.0 0"

(610)

14.00"

(356)

460A A -4G /4T

5@ (16K / 16K )

2@ (33K / 30K )

Отзывы: