DIAGNOSTIC MESSAGES
Persistent low flow problems. (Displays on the fifth occurrence
of “
HFL
” message within 24 hours.) Heater is shut down,
but other spa functions continue to run normally.
Follow action required for “
HFL
” message. Heating capability
of the spa will not reset automatically; you may press any
button to reset.
Possible inadequate water, poor flow, or air bubbles
detected in the heater. Spa is shut down for 15 minutes.
Check water level in spa. Refill if necessary. If water level
is okay, make sure the pumps have been primed. Press
any button to reset, or this message will automatically reset
within 15 minutes. If problem persists, contact your dealer
or service organization.
Inadequate water detected in heater. (Displays on third
occurrence of “dr” message.) Spa is shut down.
Follow action required for “dr” message. Spa will not
automatically reset. Press any button to reset.
23
24
MAINTAINING YOUR SPA
PILLOW CARE
Clean the pillows with soapy water and a soft cloth when needed. Use
a vinyl conditioner once a month. Remove pillows when doing chemical
shock treatment.
JET CARE
We recommend that you clean your jets when you drain your spa.
1) Spray jet inserts with a mixture of 1 part vinegar to two parts warm
water and let soak for 10-15 minutes. Periodically rotate the spinner
nozzle to break up residue in the jets.
2) Soak jet inserts in a mixture of 1 part vinegar to two parts warm water
for 2-3 hours. Periodically rotate the spinner nozzle to break up residue
in the jets.
Sensors are out of balance. If alternating with spa
temperature, it may just be a temporary condition. If flashing
by itself, spa is shut down.
If the problem persists, contact your dealer or service organization.
A significant difference between temperature sensors has
been detected. This could indicate a flow problem.
Check water level in spa. Refill if necessary. If the water level
is okay, make sure the pumps have been primed. If problem
persists, contact your dealer or service organization.
“Ice” - Potential freeze condition
No action required. The pump and blower will automatically
activate regardless of spa status.
Spa is shut down. The sensor that is plugged into the
Sensor “A” jack is not working.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)